Basic Operation
-28
Items on the INPUT 3 or 4 Mode Menu Bar
Main menu
Main menu
Sub menu
Picture (     )
Tint
Ⳮ30
ⳮ30
Ⳮ30
ⳮ30
Color
Ⳮ30
ⳮ30
Sharp
Contrast
Ⳮ30
ⳮ30
Bright
Ⳮ30
ⳮ30
Red
Ⳮ30
ⳮ30
Blue
Ⳮ30
ⳮ30
Digital Shift
Ⳮ30
ⳮ30
Subtitle
Ⳮ10
ⳮ10
Reset
Reset
5500k
3D Progressive
6500k
3D Progressive
3D Progressive
8500k 
3D Progressive
9300k
3D Progressive
10500k
3D Progressive
Standard
3D Progressive
Black Detail
3D Progressive
White Detail
3D Progressive
Memory 2
3D Progressive
Memory 3
3D Progressive
Memory 4
3D Progressive
Memory 5
Auto
3D Progressive
Memory OFF
3D Progressive
Brighten
Background
Options (     )
PAL
NTSC3.58
NTSC4.43
PAL–M
PAL–60
SECAM
Language (     )
English
Deutsch
Español
Nederlands
Français
Italiano
Svenska
Português
Blue
None
Auto Power Off  [ON/OFF]
Menu Position
Menu Color
Opaque
Translucent
Center
PRJ Mode (     )
Front
Ceiling
ⳭFront
Rear
Ceiling
ⳭRear
7500k
CLR Temp
Gamma
White Emphasis   [ON/OFF]
Picture Setting
3D Progressive
Memory 1
Lamp Timer
OSD Display   [ON/OFF]
Video System
PAL–N
Upper Right
Lower Right
Upper Left
Lower Left
*
Menu Bars
Sub menu
* The “Digital Shift” and “Subtitle” cannot be adjusted when
Keystone correction is applied.
• Only the items highlighted in the tree charts above can
be adjusted.
• To adjust the items under the sub menu, press 
 after
selecting the sub menu.
• “Tint” cannot be used with PAL, SECAM, PAL-M, PAL-N or
PAL-60.
Basic Operation
-29
2, 3
1, 4
Adjusting the Picture
You can adjust the projector’s picture to your prefer-
ences with the following picture settings. To save the
settings, select a memory from 1 to 5 and OFF (see
page 32) and then adjust the settings.
Description of Adjustment Items
For less contrast
For less brightness
For less colour intensity
Skin tones become purplish
For less sharpness
For weaker red
For weaker blue
Selected item
For more contrast
For more brightness
For more colour intensity
Skin tones become greenish
For more sharpness
For stronger red
For stronger blue
 button
 button
For selecting a desired item from six colour temperature
settings
For selecting a desired item from four gamma positions
For switching “on” or “off” the function that emphasizes
bright portions of the image
For storing all items set in “Picture”
All image adjustment items are returned to the factory
preset settings.
Contrast
Bright
Color
Tint
Sharp
Red
Blue
CLR Temp
Gamma
White Emphasis
Picture Setting
Reset
On-screen Display
e. g. (VIDEO input in INPUT 3 or 4 mode)
1
2
• “Color”, “Tint” and “Sharp” do not appear for RGB input in
INPUT 2 mode.
• For details on “Gamma”, see “Gamma Correction
Function” on page 31.
• For details on “CLR Temp”, see “Adjusting the Colour
Temperature” on page 30.
• For details on “White Emphasis”, see “Description of
White Emphasis” on page 30.
• For details on “Picture Setting”, see “Picture Setting
Function” on page 32.
1 Press MENU. The “Picture” menu screen appears.
2 Press  /   to select a specific adjustment item.
3 Press  /  to move the   mark of the selected
adjustment item to the desired setting.
4 To exit the menu screen, press MENU.
• To reset all adjustment items, select “Reset” on the “Picture”
menu screen and press ENTER.
• “Tint” cannot be used with PAL, SECAM, PAL-M, PAL-N or
PAL-60.
Basic Operation
-30
Adjusting the Picture
Adjusting the Colour Temperature
This function allows for selecting the desired colour
temperature from six settings. With the lower value
selected, the projected image becomes warmer,
reddish and incandescent-like while with the higher
value, the image becomes cooler, bluish and
fluorescent-like.
Description of Colour Temperature
1 Press MENU. The “Picture” menu screen appears.
2 Press  /  to select “CLR Temp”, and then press
.
3 Press 
/
 to select the desired colour
temperature setting.
4 Press ENTER to save the setting.
5 To exit the menu screen, press MENU.
• Values on “CLR Temp” are only for general standard
purposes. The less the value is set to, the warmer, reddish,
incandescent-like the image becomes. The more the value
is set to, the cooler, bluish, fluorescent-like the image
becomes.
On-screen Display
2, 3
4
1, 5
Emphasising the Contrast
This function emphasizes the bright portions of images
to obtain a higher contrast image.
Description of White Emphasis
1 Press MENU. The “Picture” menu screen appears.
2 Press  /  to select “White Emphasis”.
3 Press  /  to select the desired white emphasis
setting.
4 To exit the menu screen, press MENU.
On-screen Display
1, 4
2, 3
Description
Selected item
For emphasizing the bright portions of images
For disabling “White Emphasis”
ON (
)
OFF (
)
Basic Operation
-31
Gamma Correction Function
Gamma is an image quality enhancement function.
Four gamma settings are available to allow for
differences in the brightness of the room.
Description of Gamma Modes
Description
Selected Mode
Standard
Black Detail
White Detail
Brighten
Standard picture without gamma correction
Gives greater depth to darker portions of
images for a more exciting theatre experience.
Emphasizes the gradation of the intermediate to
high brightness portions of the image for more
detailed expression.
Brighten the darker portions of images for easier
viewing in a dimly lit room.
1 Press MENU. The “Picture” menu screen appears.
2 Press  /  to select “Gamma”, and then press
.
3 Press  /  to select the desired gamma mode.
4 Press ENTER to save the setting.
5 To exit the menu screen, press MENU.
On-screen Display
Standard
Black Detail
White Detail
Brighten
2, 3
4
1, 5
Adjusting the Picture
Page of 18
Display

Sharp XV-Z90E (serv.man28) User Manual / Operation Manual ▷ Download

  • DOWNLOAD Sharp XV-Z90E (serv.man28) Service Manual ↓ Size: 1.88 MB | Pages: 18 in PDF or view online for FREE
  • Here you can View online or download the User Manual / Operation Manual for the Sharp XV-Z90E (serv.man28) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XV-Z90E (serv.man28) Projector. Information contained in Sharp XV-Z90E (serv.man28) User Manual / Operation Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.