Maintenance Indicators
Version 1.1
Issue 04/2006
9
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Maintenance indicator
Normal
Abnormal
Condition
Problem
Possible Solution
• 
Blocked air intake
• 
Relocate the
projector to an
area with proper
ventilation.
Temperature
warning
indicator
Off
Red on
(Standby)
The internal
temperature is
abnormally high.
• 
Cooling fan breakdown
• 
Internal circuit failure
• 
Clogged air intake
• 
Take the projector
to your nearest
Sharp Authorised
Projector Dealer or
Service Centre.
• 
Clean the exhaust
and intake vents
Red on
Time to change the
lamp
• 
Remaining lamp life is
5% or less.
Lamp
replacement
indicator
Green on
(Green
blinks when
the lamp is
active.)
Red on
(Standby)
The lamp does not
illuminate.
• 
Burnt-out lamp
• 
Lamp circuit failure
• 
Carefully replace
the lamp. Take the
projector to your
nearest
• 
Sharp Authorised
Projector Dealer or
Service Centre for
repair.
• 
Please exercise
care when
replacing the lamp
Important Information
• 
If the temperature warning indicator illuminates and the projector enters the standby mode, check
whether any of the ventilation holes are blocked and then try turning the power back on. Wait until
the projector has cooled down completely before plugging in the power cord and turning the power
back on. (At least 10 minutes.)
• 
If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the lamp indicator will illuminate
in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace
the power cord in the AC outlet and then turn the power on again.
• 
Do not unplug the power cord after the projector has entered the standby mode and while the
cooling fan is running. The cooling fan runs for about 90 seconds.
Lamp Replacement Procedure
Version 1.1
Issue 04/2006
10
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Lamp
• 
It is recommended that the lamp unit (optional: AN-100LP) be replaced when the remaining lamp
life becomes 5% or less, or when you notice a significant deterioration in the picture and colour
quality. The lamp life (percentage) can be checked with the on-screen display.
• 
Purchase a replacement lamp unit of type AN-100LP from your place of purchase, nearest Sharp
Authorised Projector Dealer or Service Centre.
Caution Concerning the Lamp
• 
This projector utilises a pressurised mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time. The period of time up to failure
largely varies depending on the individual lamp and/or the condition and the frequency of use. It is
important to note that failure can often result in the bulb cracking.
• 
When the lamp replacement indicator and on-screen display icon are illuminated or flash, it is
recommended that the lamp be replaced with a new one immediately, even if the lamp appears to
be operating normally.
• 
Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
case of exposure to the gas, consult with a doctor as soon as possible.
• 
Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorised Projector
Dealer or Service Centre to remove the damaged lamp and assure safe operation.
Replacing the Lamp
*Caution*
• 
Do not remove the lamp unit immediately after operation of the projector. The lamp will be
hot and touching it can lead to burn or injury.
• 
Wait at least one hour after the power cord is disconnected to allow the surface of the
lamp unit to fully cool before removing the lamp unit.
• 
If the new lamp does not light after replacement, take your projector to the nearest Sharp
Authorised Projector Dealer or Service Centre for repair. Purchase a replacement lamp
unit of type AN-100LP from your nearest Sharp Authorised Projector Dealer or Service
Centre. Then carefully change the lamp by following the instructions described in this
section. If you wish, you may have the lamp replaced at your nearest Sharp Authorised
Projector Dealer or Service Centre.
Part Number
Description
Price Rank
AN-100LP
Lamp Module
CK
Lamp Replacement Procedure
Version 1.1
Issue 04/2006
11
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Removing and Installing the Lamp Unit
 Note
• 
Ensure the lamp unit is
removed using the handle.
Ensure the glass surface of
the lamp unit or the insides of
the projector are not touched.
• 
To avoid injury to yourself and
damage to the lamp, ensure
to carefully follow the steps
below.
• 
Do not loosen other screws except for the lamp unit cover and lamp unit. (Only the silver
screws are loosened).
1. 
 Press “STANDBY” on the projector to turn off the power.
• 
Wait until the cooling fan stops.
Warning!
• 
Do not remove the lamp unit from the
projector right after use. The lamp will be
very hot and may cause burn or injury.
2. 
Disconnect the power cord.
• 
Unplug the power cord from the AC
socket.
• 
Leave the lamp until it has fully cooled
down (about 1 hour). 
Lamp Replacement Procedure
Version 1.1
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
3. 
 Remove the lamp unit cover.
• 
Turn the projector over. Loosen the user service screw (1) that secures
the lamp unit cover. Pressing the tab, remove the lamp unit cover (2).
4. 
 Remove the lamp unit.
• 
Loosen the securing screws from the lamp unit. Hold the lamp
unit by the handle and pull it in the direction of the arrow. 
5. 
Insert the new lamp unit.
• 
Press the lamp unit firmly into the lamp unit compartment.
Fasten the securing screws.
 
6. 
 Replace the lamp unit cover.
• 
Align the tab on the filter/lamp unit cover (1) and place it while
pressing the tab (2) to close it. Then tighten the user service
screw (3) to secure the filter/ lamp unit cover.
Note
• 
If the lamp unit and lamp unit cover is not correctly installed, the power will not turn on,
even if the power cord is connected to the projector.
Page of 39
Display

Click on the first or last page to see other XV-Z100 service manuals if exist.