1 – 9
[4] Regarding the lamp
Lamp
It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes
5% or less, or when you notice a significant deterioration in the picture and color quality. The lamp life
(percentage) can be checked with the on-screen display.
Purchase a replacement lamp of type AN-XR10L2 from your place of purchase, nearest Sharp Authorized
Caution Concerning the Lamp
ı This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time.
The period of time up to failure largely varies depending on the individual lamp and/or the condition
and the frequency of use. It is important to note that failure can often result in the bulb cracking.
ı When the lamp replacement indicator and on-screen display icon are illuminated, it is recommended
that the lamp be replaced with a new one immediately, even if the lamp appears to be operating
normally.
ı Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector
Dealer or Service Center to assure safe operation.
ı Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In case
of exposure to the gas, consult a doctor as soon as possible.
Replacing the Lamp
Caution
Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may
cause burn or injury.
ı
Carefully change the lamp by following the instructions described in this section. * If you wish,
you may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service
Center.
* If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized
Projector Dealer or Service Center for repair.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited
warranty. All service of this projector under warranty, including lamp replacement,
must be obtained through a Sharp Authorized Projector Dealer or Service Center.
For the name of the nearest Sharp Authorized Projector Dealer or Service Center,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal
Information
www.lamprecycle.org or 1-800-BE-SHARP
U.S.A. ONLY
Regarding the Lamp
Projector Dealer or Service Center.
XR-10X-L/XR-10S-L/XG-MB50X-L/XR-11XC-L/XR-HB007X-L
1 – 10
Removing and Installing the
Lamp Unit
Make sure that you remove the lamp unit by
the handle. Do not touch the glass surface of
the lamp unit or the inside of the projector.
To avoid injury to yourself and damage to the
lamp, make sure you carefully follow the steps
below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
Press
STANDBY/ON on the pro-
jector or
STANDBY on the re-
mote control to put the projector
into standby mode.
Wait until the cooling fan stops.
Warning!
Do not remove the lamp unit from the projec-
tor right after use. The lamp and parts around
the lamp will be very hot and may cause burns
or injury.
Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
Remove the lamp unit cover.
Turn the projector over. Loosen the user
service screw (ı ) that secures the lamp
unit cover. Remove the lamp unit cover
(ˇ ).
1
1
2
2
Lamp unit
AN-XR10L2
(for XG-MB50X-L/
XR-11XC-L/XR-10X-L/
XR-10S-L/
XR-HB007X-L)
Info
Optional
accessory
AC socket
User service screw
(for lamp unit cover)
STANDBY/ON button
3
2
1
1
XR-10X-L/XR-10S-L/XG-MB50X-L/XR-11XC-L/XR-HB007X-L
1 – 11
Regarding the Lamp (Continued)
Remove the lamp unit.
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
Align the tab on the lamp unit cover
(ı )and place it while pressing the tab
(ˇ ) to close it. Then tighten the user ser-
vice scr ew (
) to secure the lamp unit
cover.
Connect the power cord.
Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
While simultaneously holding down
MENU/HELP,
ENTER and
on the
projector, press
STANDBY/ON on the
projector.
"LAMP 0000H" is displayed, indicating
that the lamp timer is reset.
Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
Info
AC socket
Securing screws
Handle
ENTER button
MENU/HELP
button
button
If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info
2
1
1
2
3
3
STANDBY/ON
button
1
2
1
4
5
5
6
XR-10X-L/XR-10S-L/XG-MB50X-L/XR-11XC-L/XR-HB007X-L
1 – 11
Regarding the Lamp (Continued)
Remove the lamp unit.
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
Align the tab on the lamp unit cover
(ı )and place it while pressing the tab
(ˇ ) to close it. Then tighten the user ser-
vice scr ew (
) to secure the lamp unit
cover.
Connect the power cord.
Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
While simultaneously holding down
MENU/HELP,
ENTER and
on the
projector, press
STANDBY/ON on the
projector.
"LAMP 0000H" is displayed, indicating
that the lamp timer is reset.
Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
Info
AC socket
Securing screws
Handle
ENTER button
MENU/HELP
button
button
If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info
2
1
1
2
3
3
STANDBY/ON
button
1
2
1
4
5
5
6
Page of 11
Display

Sharp XR-10XL (serv.man11) User Manual / Operation Manual ▷ Download