DOWNLOAD Sharp XG-NV51XE (serv.man5) Service Manual ↓ Size: 317.17 KB | Pages: 5 in PDF or view online for FREE

Model
XG-NV51XE (serv.man5)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
317.17 KB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Removal of major parts
File
xg-nv51xe-sm5.pdf
Date

Sharp XG-NV51XE (serv.man5) Service Manual ▷ View online

11
XG-NV51XE/XM/XA
REMOVING OF MAJOR PARTS
1. Removing the Intake cover and lamp unit
1-1. Detach the Intake cover.
1-2. Loosen the lamp cover screw and draw out the lamp cover in the direction of arrow (toward yourself).
1-3. Remove the two lamp unit lock screws. Detach the lamp unit.
Note:
When replacing the lamp, make sure
that there is a clearance of over
8mm between the terminal and the
lamp snap-on spring (and other
metallic parts).
SHARP
1-3
1-3
1-2
1-1
Intake cover
Lamp snap-on spring
Lamp unit
Lamp cover
12
XG-NV51XE/XM/XA
2. Removing the top and rear cabinets
2-1. Remove the five rear cabinet lock screws.
2-2. Remove the four terminal board lock screws off the rear cabinet. Unhook and detach the rear cabinet from
below.
2-3. Remove the four top cabinet lock screws from below.
2-4. Slowly lift the top cabinet and disconnect the operation key unit connector (KY). Then take away the top
cabinet.
SHARP
2-4
(KY)
SHARP
2-3
2-2
2-1
Rear cabinet
Top cabinet
Hook
Press both sides of the bottom
cabinet in the directions of
arrow to undo the hooks. Lift
and detach the top cabinet.
13
XG-NV51XE/XM/XA
3. Removing the PWB units
3-1. Disconnect the connectors.
3-2. Remove the twelve screws and detach the output Unit top shield.
3-3. Remove the two screws and detach the PC I/F Unit.
3-4. Remove the two screws and the spacer (stud bolt).Lift and detach the Unit assembly.
3-5. Remove the S-out/REG unit angle lock screw and take out the S-out/REG unit.
3-1
3-5
(FP)
(FS)
(Q)
(FN)
(EB)
(EB)
(SO)
(SP)
(EA)
(F)
(SO)
3-1
(L)
3-3
3-2
3-4
3-4
3-4
(EB)
Output Unit top shield
Spacer (stud bolt)
Output Unit
S-out/REG Unit Angle
S-out/REG Unit
PC I/F Unit
Signal Unit
PC Terminal Unit
14
XG-NV51XE/XM/XA
4. Removing the Power/Ballast unit assembly
4-1. Remove the Power/Ballast unit assembly lock screw.
4-2. Remove the two lamp socket holder lock screws and take out the holder.
4-3. Disconnect the connector (BA) from the ballast unit.
4-4. Remove the (FG) lead lock screw.
4-5. Lift the Power/Ballast unit assembly off the position.
Power/Ballast Unit Ass'y
4-4
4-1
4-5
4-3
4-2
(FG)
(BA)
Page of 5
Display

Sharp XG-NV51XE (serv.man5) Service Manual ▷ Download

  • DOWNLOAD Sharp XG-NV51XE (serv.man5) Service Manual ↓ Size: 317.17 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XG-NV51XE (serv.man5) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XG-NV51XE (serv.man5) Projector. Information contained in Sharp XG-NV51XE (serv.man5) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.