DOWNLOAD Sharp XG-C55X (serv.man29) Service Manual ↓ Size: 9.04 MB | Pages: 106 in PDF or view online for FREE

Model
XG-C55X (serv.man29)
Pages
106
Size
9.04 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Projector
File
xg-c55x-sm29.pdf
Date

Sharp XG-C55X (serv.man29) User Manual / Operation Manual ▷ View online

Appendix
-81
Replacing the Air Filter
Air filter
M4
M4
M4
M4
STANDBY button
STANDBY
button
Air filter (not removable)
• This projector is equipped with air fil-
ters to ensure the optimal operating
condition of the projector.
• The air filters should be cleaned ev-
ery 100 hours of use. Clean the filters
more often when the projector is used
in a dusty or smoky location.
• Ask your nearest Sharp Authorized
Projector Dealer or Service Center to
exchange the filter (PFILDA005WJZZ)
when it is no longer possible to clean.
Cleaning and replacing
the bottom air filter
1
Press 
STANDBY
 on the projector
or 
 on the remote control to
put the projector into the
standby mode.
• Wait until the cooling fan stops.
2
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
3
Remove the bottom filter cover.
• Turn over the projector. Grab the tab
and slide open the filter cover in the
direction of the arrow.
4
Remove the air filter.
• Pick the air filter up with your fingers
and lift it out of the filter cover.
AC socket
Tab
5
Clean the air filter.
• Clean the dust off the air filter and
cover with a vacuum cleaner extension
hose.
6
Replace the air filter.
• Place the air filter underneath the tabs
on the filter cover.
7
Replace the filter cover.
• Slide the filter cover in the direction of
the arrow to close it.
Note
• Be sure the filter cover is securely
installed. The power will not turn on
unless it is correctly installed.
• If dust or dirt has collected inside the
bottom air filter (not removable), clean the
filter with a vacuum cleaner extension
hose.
Replacing the Air Filter
-82
Appendix
-83
Maintenance Indicators
■ The warning lights on the projector indicate problems inside the projector.
■ If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
Temperature warning
indicator
Lamp indicator
Power indicator
About the temperature warning indicator
If the temperature inside the pro-
jector increases, due to blockage
of the air vents, or the setting lo-
cation, “
” will blink in the
lower left corner of the picture. If
the temperature keeps on rising,
the lamp will turn off and the tem-
perature warning indicator will
blink, the cooling fan will run for
further 90 seconds, then the pro-
jector will enter the standby mode.
After “
” appears, be sure to
perform the following measures.
About the lamp indicator
■ The lamp life becomes 0%, when used
for approximately 3,000 hours with “ON”
in “Power Save” or when used for approxi-
mately 2,000 hours with “OFF” in “Power
Save” (see page 
69
).
■ When the remaining lamp life becomes
5% or less, “
” will be displayed on the
screen in yellow. When the percentage
becomes 0%, “
” will change to “
(red), the lamp will automatically turn off
and then the projector will automatically
enter the standby mode. At this time, the
lamp indicator will illuminate in red.
■ If you try to turn on the projector a fourth
time without replacing the lamp, the pro-
jector will not turn on.
Maintenance indicator
Condition
Problem
Possible Solution
Temperature
warning
indicator
Normal
Abnormal
Off
Red on/
Standby
The internal
temperature is
abnormally high.
Abnormal
• Blocked air intake
• Relocate the projector to an area
with proper ventilation.
• Cooling fan break-
down
• Internal circuit failure
• Clogged air intake
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page 
96
)
for repair.
Lamp
indicator
Red on/
Standby
The lamp does
not illuminate.
• Burnt-out lamp
• Lamp circuit failure
• Carefully replace the lamp. (See
page 
86
)
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page 
96
)
for repair.
• Please exercise care when
replacing the lamp.
Green on
Green
blinks
when the
lamp is
warming up
 or shutting
down.
Red blinks/
Red on
Time to change
the lamp
• Remaining lamp life
becomes 5% or
under.
Power
indicator
The power
indicator blinks
in red when the
projector is on.
• The filter cover, lamp
unit cover or lens
cover is open.
• Securely install the covers.
• If the power indicator blinks even
when the filter cover is securely
installed, contact your nearest
Sharp Authorized Projector Dealer
or Service Center for advice.
Green on/
Red on
Red blinks
-84
Maintenance Indicators
Info
• If the temperature warning indicator illuminates, and the projector enters the standby mode, follow the pos-
sible solutions on the previous page and then wait until the projector has cooled down completely before
plugging in the power cord and  turning the power back on. (At least 5 minutes.)
• If the power is turned off for a brief moment due to power outage or some other cause while using the
projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red and
the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power cord in the
AC outlet and then turn the power on again.
• If you want to clean the air vents during projector operation, be sure to put the projector into the standby
mode. After the cooling fan has stopped, clean the vents.
• Do not unplug the power cord after the projector has entered the standby mode and while the cooling fan is
running. The cooling fan runs for about 90 seconds.
Page of 106