DOWNLOAD Sharp XG-C50XE Service Manual ↓ Size: 1.09 MB | Pages: 56 in PDF or view online for FREE

Model
XG-C50XE
Pages
56
Size
1.09 MB
Type
PDF
Document
Handy Guide
Brand
Device
Projector / Version 1.5
File
xg-c50xe.pdf
Date

Sharp XG-C50XE Handy Guide ▷ View online

Adjustment of the Mirrors
Version 1.5
Issue 04/2006
46
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjusting the mirrors
This adjustment is needed when any of the optical parts of the optical mechanism has been
replaced.
1. Disconnect the flat cables from all the LCD panels.
2. Light up the lamp.
3. Project a white-light image and check to see if there is any colour tint in any direction. If
any, use the M2, M4 and M5 adjusting levers.
4. Loosen the adjusting lever lock screws, make adjustments, and tighten up the lock screws.
Adjustment of the Mirrors
Version 1.5
Issue 04/2006
47
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjustment of the Mirrors
Version 1.5
Issue 04/2006
48
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Correcting colour irregularities on white-only screen when replacing the
lamp
If colour irregularities are found at the right and left on a white-only screen after replacing the
lamp, it is necessary to readjust the optical axis of the new lamp. Take the following steps.
1. Open the lamp cover and loosen the screws A and B at the bottom of the lamp.
2. Using a screwdriver or the like, move the U-shaped groove at the window D in the arrow
direction.
3. Temporarily fix the screws A and B, close the lamp cover, and check the white-only screen
again for colour irregularities.
4. Repeat the above steps 1 and 2 until there will be no colour irregularities. Now tighten up
the screws A and B.
5. Finally secure the lamp cover back in position.
Product Safeguards
Version 1.5
Issue 04/2006
49
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
SAFETY NOTICE
Many electrical and mechanical parts in Projector have special safety-related characteristics.
These characteristics are often not evident from visual inspection, nor can protection afforded
by them be necessarily increased by using replacement components rated for higher voltage,
wattage, etc.
Replacement parts which have these special safety characteristics are identified in the
service manual; electrical components having such features are identified by 
 and
shaded areas in the Replacement Parts Lists and Schematic Diagrams. For continued
protection, replacement parts must be identical to those used in the original circuit. The use of
a substitute replacement parts which do not have the same safety characteristics as the
factory recommended replacement parts shown in the service manual, may create shock, fire
or other hazards.
WARNING: The bimetallic component has the primary conductive side exposed. Be very careful in handling
this component when the power is on.
NOTE TO SERVICE PERSONNEL
UV-RADIATION PRECAUTION
The light source, metal halide lamp, in the projector emits small amounts of UV-
Radiation.
AVOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear UV protective glasses when servicing the projector
with the lamp turned “on” and the top enclosure removed.
2. Do not operate the lamp outside of the lamp housing.
3. Do not operate for more than 2 hours with the enclosure
removed.
UV-Radiation and Medium Pressure
Lamp Precautions
1. Be sure to disconnect the AC plug when replacing the lamp.
2. Allow one hour for the unit to cool down before servicing.
3. Replace only with same type lamp. Type BQCXGC50X//1 rated 85V/250W.
4. The lamp emits small amounts of UV-Radiation, avoid direct-eye contact.
5. The medium pressure lamp involves a risk of explosion. Be sure to follow installation
instructions described in the Lamp Replacement Procedure and handle the lamp with care.
Page of 56
Display

Click on the first or last page to see other XG-C50XE service manuals if exist.