DOWNLOAD Sharp XG-C430X Service Manual ↓ Size: 33.67 MB | Pages: 127 in PDF or view online for FREE

Model
XG-C430X
Pages
127
Size
33.67 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service Manual
File
xg-c430x.pdf
Date

Sharp XG-C430X Service Manual ▷ View online

XG-C330X/C430X
4 – 3
5. Clock on the above position and select the latest software
If you mistook the folder, please select the unpacked folder.
6. There is file named " pwSDK.inf " in this folder.
XG-C330X/C430X
4 – 4
7. Double-click on the "pwSDK.inf". 
Note: 
Options: Continuous Flash Mode; Do not put check point.
                Notify On Completion; Do not put check point.
                Reset Target After download; Put the check point.
 Modes: Put the check point in “Flash”.
8. Click on the “Flash” button. 
Then, below image will be appeared.
Now, preparation is completed.
XG-C330X/C430X
4 – 5
9. Next, connect the AC cord of the projector and software rewriting will start automatically. 
If the gauge is not started, please check the “LEAF SW JIG” or “Write SW”.
Rewriting times are about 3 or 4 minutes.
Do not disconnect the AC cord by at this time. 
Below window is under writing.
And below window will appear after software rewriting is completed.
Please click on “Close “ and software rewriting is finished. 
10.Remove the LEAF SW JIG : PSPAZB245WJKZ and attach the filter cover.
Or select S2701 of main PWB to “NORMAL” side and attach the top cabinet.
Projector will be Normal mode(Non-writing mode)
XG-C330X/C430X
4 – 6
3. Rewriting of the model name
1. Rewriting of the Model name will be done with the Tera Term.
2. Send the following command.
“MF1_0000”   for XG-C430X
“MF1_0001”    for XG-C330X
3. Remove the AC cord
4. Confirmation of version.
1. Enter the “factory mode”,
With the menu not displayed, press the “ENTER”, “ENTER”, “VOL+”, “VOL-”, “ENTER”, “ENTER” and “MENU” keys on the projector
2. Below image is appeared and select “VERSION”.
Latest version will be appered.
[2] ELCTRICAL ADJUSTMENT
1. ELECTROCAL ADJUSTMENT (1)
No.
Adjustment Item
Adjustment Conditions
Adjustment Procedures
1
EEPROM initialization
1)  Turn on the power (the lamp turns on) 
and perform aging for 15 minutes.
1) Perform the following setting.
Press S6501 to enter the process mode, and execute SS2 of the 
SS menu.
2
R-bright check
Contrast adjustment 
(manual or automatic)
1) Input the white/black wind pattern sig-
nal of amplitude level 96% (0.67 Vpp)/
0% of  XGA60Hz to COMPUTER1.
2) Select the following.
Group: AD
Adjustment item: R-Bright
                                R-Contrast
(Process gamma linkage)
1) Check the fixed value.
R-Bright: 63
2) Observe the chromaticity of 96% white wind pattern portion using 
CA100.
3) On the screen where bit dropouts occur, raise the R-Contrast 
value. Adjust to the point where black to bright red bit dropouts 
occur and the x value changes by 30/1000 or more.
Page of 127
Display

Click on the first or last page to see other XG-C430X service manuals if exist.