DOWNLOAD Sharp XG-C40XE (serv.man3) Service Manual ↓ Size: 6.34 MB | Pages: 33 in PDF or view online for FREE

Model
XG-C40XE (serv.man3)
Pages
33
Size
6.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service manual section 2 - Additional and amended information
File
xg-c40xe-sm3.pdf
Date

Sharp XG-C40XE (serv.man3) Service Manual ▷ View online

6
XG-C40XU
(
1
)
XG-C40XE
(
1
)
No.
Adjusting point
Adjusting conditions
Adjusting procedure
13
Horizontal
center
1. Feed the NTSC monoscope
pattern signal.
2. Group : VIDEO 2
Subject : N358-DLY     (4)
N443-DLY     (0)
PAL-DLY       (3)
SECAM-DLY (0)
Make sure the settings are
    as above.
3. Group : VIDEO 1
Subject : NTSC-H
»
Using the control switches or the remote controller
buttons, adjust the data to have the same overscan
in Reft and Right.
2.0Vp-p
14
Video picture
adjustment
1. Feed the split colour bar sig-
nal.
Group : VIDEO 1
Subject : PICTURE
2. Connect the oscilloscope
between pin (2) of P801 and
GND.
»
Using the control switches or the remote controller
buttons, adjust the black-to-white (100%) level
difference to 2.0 
±
0.06 Vp-p.
17
Tint
1. Feed the split colour bar
signal.
Group : VIDEO 1
Subject : TINT
2. Connect the oscilloscope to
pin (4) of P801.
»
Using the control switches or the remote controller
buttons, adjust the data to have the -(B-Y) wave-
form downhill straight.
»
After adjusting, adjust the
value of TINT up 3 point.
16
Video AGC
1. Feed the split colour bar signal.
Group : VIDEO 1
Subject : AGC
»
Using the control switches or the remote controller
buttons, adjust the setting until the white signal
becomes bit-less.
15
Video
brightness
adjustment
1. Feed the baseband (split
colour bar) signal. (The ON-
AIR signal is not accepted
because of its too much
noise.)
Group : VIDEO 2
Subject : VROS/VGOS/VBOS
2. Press the control switch or
the remote control’s mute
button (to set the gamma
correction to the process
setting).
»
Using the control switches or the remote controller
buttons, adjust the setting until the black signal
becomes bit-less.
100% White Red
18
NTSC colour
saturation level
1. Feed the split colour bar sig-
nal.
Group : VIDEO 1
Subject : N-COLOR
2. Connect the oscilloscope to
pin (1) of P801.
»
Using the control switches or the remote controller
buttons, adjust the difference between the 100%
white portion and the red portion to 0.00 
±
0.05 Vp-p.
   (same as 100% white)
7
XG-C40XU
(
1
)
XG-C40XE
(
1
)
100% White Red
100% White Red
No.
Adjusting point
Adjusting conditions
Adjusting procedure
19
PAL colour
saturation level
1. Feed the PAL colour bar sig-
nal.
Group : VIDEO 1
Subject : P-COLOR
2. Connect the oscilloscope to
pin (1) of P801.
»
Using the control switches or the remote controller
buttons, adjust the difference between the 100%
white portion and the red portion to 0.2 
±
0.05 Vp-p.
20
SECAM colour
saturation level
1. Feed the SECAM colour bar
signal.
Group : VIDEO 1
Subject : S-COLOR
2. Connect the oscilloscope to
pin (1) of P801.
»
Using the control switches or the remote controller
buttons, adjust the data to have a level difference
of 0.2 
±
0.05 Vp-p between the 100% white portion
and the red portion.
21
Video input
panel signal
amplitude
adjustment
1. Feed the NTSC 10-step sig-
nal.
2. Select the following group
and subject.
Group  :  VIDEO2
Subject: R1-GAIN
B1-GAIN
3. Connect the oscilloscope to
TP1101 (R) and TP1201 (G).
4. For the blue colour, connect
the oscilloscope to TP1301
(B) and TP1201 (G).
»
Select R1-GAIN and adjust the setting so that the
R and G signals have the same amplitude.
»
For the blue colour, adjust the setting the same
way.
22
Video white
balance
1. Feed the NTSC monoscope
pattern signal
Group : VIDEO 2
Subject : R1-BLK
B1-BLK
»
Using the control switches or the remote controller
buttons, adjust so that the entire screen looks
evenly colourless.
23
DTV white
balance
1. Feed the monoscope pattern
signal.
2. Group  : DTV
Subject: CR-OFFSET
CB-OFFSET
»
Using the control switches or the remote controller
buttons, adjust so that the entire screen looks
evenly colourless.
24
Setup
1. Group  :  VIDEO1
Subject: SET UP B
SET UP C
»
Make sure the settings are 11 for SET UP B and 2
for SET UP C.
25
Automatic
colour
errugularity
correction
1. Using the colour errugularity
correction system (ccdc),
apply automatic colour
correction.
»
Make sure there is no noticeable colour irregularity
left on the screen.
8
XG-C40XU
(
1
)
XG-C40XE
(
1
)
No.
Adjusting point
Adjusting conditions
Adjusting procedure
26
Colour system
performance
check
1. Receive the colour bar sig-
nal.
»
In the process mode and select L1. Check the col-
our and tint.
27
Video system
performance
check
1. Receive the monoscope pat-
tern signal.
»
In the process mode and select L2. Check the pic-
ture, brightness and sharpness.
28
Audio system
performance
check
»
In the process mode nad select L3. Check the bass,
treble.
29
RGB
performance
check
1. Receive the RGB signal.
»
In the process mode and select L4. Check the pic-
ture, brightness, red, blue, clock, phase, horizontal
position, and vertical position.
30
Off-timer
performance
check
»
In the process mode and select OFF. Make sure that
the off-timer starts with “5” (minutes), counts down each
minute in 1 second, and turns off the set at “0”.
31
Thermistor
performance
check
1. Heat the thermistor using a
dryer.
»
Make sure the “TEMP” is displayed.
32
Automatic
synchronization
1. Receive the PHASE check
pattern signal.
»
Call the VGA/SVGA/XGA/SXGA mode and make
sure that the clock, phase, horizontal and vertical
positions can be automatically adjusted.
33
Keystone
correction
performance
check
»
Make sure the keystone correction functions well.
34
Factory settings
»
Make the following settings.
S3
“Factory setting 3”(XG-C40XE1)
S4
“Factory setting 4”(XG-C40XU1)
Process
adjustment
Remote controller setting
9
XG-C40XU
(
1
)
XG-C40XE
(
1
)
Ref.Nr.
Beschreibung
Bestehend
Neu
Bemerkung
   LCD PANELS
XG-C40XU(1) 
/
 XG-C40XE(1)
LCD Module Unit Red
RLCDP141CEZZ
RLCDPA004WJZZ
LCD Module Unit Green
RLCDP142CEZZ
RLCDPA005WJZZ
LCD Module Unit Blue
RLCDP143CEZZ
RLCDPA006WJZZ
   PWB ASSEMBLIES
XG-C40XU(1)
Signal Unit
DUNTKA211DE11
DUNTKB116DE04
Sechs Teile verändert
PC Terminal Unit
DUNTKA212DE11
DUNTKB117DE04
Keine Teile verändert
S-Out/Regulater Unit
DUNTKA693FE01
DUNTKA693FE04
Keine Teile verändert
Output Unit
DUNTKA694FE01
DUNTKB181FE01
Video Unit
DUNTK9769DE24
AC Inlet Unit
RUNTK0677CEZZ
Power Unit
RDENC0334CEZZ
Ballast Unit
RDENC0333CEZZ
PC I/F Unit
CPCi-0047CE15
CPCi-0047CE18
Keine Teile verändert
   PWB ASSEMBLIES
    XG-C40XE(1)
Signal Unit
DUNTKB116DE02
DUNTKB116DE05
Keine Teile verändert
PC Terminal Unit
DUNTKB117DE02
DUNTKB117DE05
Keine Teile verändert
S-Out/Regulater Unit
DUNTKA693FE02
DUNTKA693FE05
Keine Teile verändert
Output Unit
DUNTKA694FE02
DUNTKB181FE02
Video Unit
DUNTK9769DE25
AC Inlet Unit
DUNTK0677CEZZ
Power Unit
RDENC0334CEZZ
Ballast Unit
RDENC0333CEZZ
PC I/F Unit
CPCi-0047CE16
CPCi-0047CE19
Keine Teile verändert
   SIGNAL UNIT
XG-C40XU(1)
   C886
Capacitor 22 16V EL.
VCEAPF1CW226M
   C887
Capacitor 10 16V EL.
VCEAPF1CW106M
   R1010
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1011
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1013
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1814
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   OUTPUT UNIT
XG-C40XU(1) 
/
 XG-C40XE(1)
     Beziehen Sie sich auf die Teilliste
   CABINET AND MECHANICAL PARTS
XG-C40XU(1) 
/
 XG-C40XE(1)
   3-2
Bottom Cabinet Ass
y
DBDYU1140CEK1
DBDYU1140CEK2
XG-C40XU1
   3-2
Bottom Cabinet Ass
y
DBDYU1141CEK1
DBDYU1141CEK3
XG-C40XE1
LISTE VON VERÄNDERTEN TEILEN
Page of 33
Display