Sharp XG-C40XE (serv.man15) Service Manual ▷ View online

21
XG-C40XU/XE
R-LCD
B-LCD
Lock screw "a"
Lock screw "c"
Notch and 
hole "c"
Notch and 
hole "b"
Lock screw "c"
G-LCD
G-LCD
Lock screw "b"
Notch and hole "c"
Notch and hole "a"
Lock screw "d"
Lock screw "d"
R·B-LCD panel 
mounting screws
(four screws)
R·B-LCD
SIDE VIEW (from inside)
SIDE VIEW (from outside)
TOP VIEW
SIDE VIEW
G-LCD panel 
mounting screws
Eccentric cam
(Y direction adjustment)
Eccentric cam
(X direction adjustment)
Eccentric cam
(
θ
Z direction adjustment)
(four screws)
4. With the G-LCD panel's screen center as refernce, adjust the R-LCD and B-LCD panels.
5. Finally tighten up the convergence lock screw "d".
Notes :
1
The eccentric cam is used for convergence adjustment.
This means that the cam's turning and the linear movement are not always uniform.
2
This model is not equipped with the LCD image adjustment mechanism. This is because the cross-dichroic
prism is used for image formation. When the LCD panels all get into best focus, the images are almost
completely converged.
Convergence and Focus Adjustments Mechanism
22
XG-C40XU/XE
80
100
2
5
16
R2
50
CUT
2
2
92
5
7.5
0.5
min85
ø5
ø3.5
3.5
Convergence and Focus Adjustments at a Glance
Adjustment directions
Adjustment
Direction
Definition
Direction of LCD panel
X direction
LCD right and left
Convergence Y direction
LCD top and bottom
θ
Z direction
Rotation around Z axis
LCD turning axis
Z direction
LCD optical axis
Focus
θ
X direction
Rotation around X axis
LCD top-to-bottom flapping
θ
Y direction
Rotation around Y axis
LCD right-to-left flapping
Convergence and Focus Adjustment for the Optical Mechanism
Colour
Adjustment
Direction
Movement
Position
Adjusting tool
Lock screw
Tightening tool
X direction
±
0.8mm Eccentric cam
Eccentric cam adjusting wrench
d
Hex wrench
Convergence
Y direction
±
0.8mm Eccentric cam
Eccentric cam adjusting wrench
d
Hex wrench
R/B
θ
Z direction
±
1
°
Eccentric cam
Eccentric cam adjusting wrench
d
Hex wrench
colours
Z direction
±
0.8mm Notch and hole "a" & "c"
Eccentric screwdriver,
a, c
Focus
θ
X direction
±
1
°
Notch and hole "a" & "c"
 Bladed screwdriver
a, c
θ
Y direction
±
1
°
Notch and hole "b" & "c"
b, c
Z direction
±
0.2mm
G colour
Focus
θ
X direction
±
1
°
Same as for R and B colours
θ
Y direction
±
1
°
Phillips
screwdriver,
*Hex wrench
Focus Adjustments the Other Way
Lock screw
Position
Related direction
a
Notch and hole "a"
Z and 
θ
X directions
b
Notch and hole "b"
θ
Y direction
c
Notch and hole "c"
Z, 
θ
X and 
θ
Y directions
Convergence and Focus Adjusting and Tightening Tools
Tool
Specific or General
Tool code
Configuration
Eccentric cam
Specific
9DASPN-XGNV1U
adjusting wrench
Eccentric screwdriver Specific
9DADRiVER-NV4U
Hex wrench
General (redesigned)
9EQLNC-XGNV1U
 
        9EQLNC-XGNV4U
Bladed screwdriver
General
9EQDRiVER-NV1B
Phillips screwdriver
General
           —
For M2.6 pan-head machine screw
*Hex wrench
General
           —
1.27mm, preferably use a 70 mm or
longer screwdriver (with a handle).
23
XG-C40XU/XE
G-LCD
SIDE VIEW
G-LCD panel 
mounting screws
Lock screw "d"
Lock screw "d"
R·B-LCD panel 
mounting screws
R·B-LCD
SIDE VIEW (from inside)
2
2
1
Prism holder
Optical Mechanism Unit
Replacing the LCD panels
Detach the top panel and the optical mechanism unit in advance.
(1) Remove the four prism holder lock screws. Detach the prism holder from the optical mechanism unit.
(2) Remove the LCD panel lock screws (four each for the R-, G- and B-LCD panels). Detach the LCD panels from the
prism holder.
(3) Mount a new LCD panel in the reverse order of the above steps (1) and (2).
~
Readjust the convergence and focus. Note that the G-LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
24
XG-C40XU/XE
FRONT
M5
 adjust lever
Lock screws
Lock screws
M4/M6
 adjust lever
Lock screws
M1
 adjust lever
Shielding plate G
slide
turn
turn
slide
turn
slide
Shielding plate R
Shielding plate B
Adjusting the optical axis of the mirrors (M1, M5 and M4/M6)
The optical axis must be readjusted if an eclipse happens with the R. G or B mirrors. Generally speaking,
this adjustment is needed when any of the internal optical components has been replaced.
Adjustment procedure required when any of the panels has been replaced or the convergence has been
adjusted
(1) Disconnect the flat cables of all the LCD panels.
(2) Let the lamp light up.
(3) To adjust the G mirror, shield the R and B mirrors with shielding plates (You can use a business card or the like to
block the light).
(4) Loosen the lock screw of the M1 adjust lever.
(5) Looking at the G image on the screen, turn or slide the M1 adjust lever until the eclipse on the screen disappears.
Tighten up the screw.
(6) To adjust the R mirror, shield the G and B mirrors and adjust the M5 adjust lever. For the B mirror, shield the R and
G mirrors and adjust the M6 adjust lever.
(Take the same steps 4 and 5 above.)
(7) Remove all the shielding plates to have a white image.
Make sure there is no eclipse.
Page of 115