DOWNLOAD Sharp PG-M25XE Service Manual ↓ Size: 669.64 KB | Pages: 42 in PDF or view online for FREE

Model
PG-M25XE
Pages
42
Size
669.64 KB
Type
PDF
Document
Handy Guide
Brand
Device
Projector / Version 1.4
File
pg-m25xe.pdf
Date

Sharp PG-M25XE Handy Guide ▷ View online

Lamp Replacement Procedure
Version 1.4
Issue 04/2006
10
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Lamp
• 
It is recommended that the lamp (sold separately) be replaced after approximately 1,900 cumulative
hours of use or when you notice a significant deterioration of the picture and colour quality. The
lamp usage time can be checked with the On-screen Display.
• 
For lamp replacement, please consult your nearest Sharp Authorised Projector Dealer or Service
Centre.
Caution Concerning the Lamp
• 
This projector utilises a pressurised mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time. The period of time up to failure
largely varies depending on the individual lamp and/or the condition and the frequency of use. It is
important to note that failure can often result in the bulb cracking.
• 
When the lamp replacement indicator and on-screen display icon are illuminated or flash, it is
recommended that the lamp be replaced with a new one immediately, even if the lamp appears to
be operating normally.
• 
Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
case of exposure to the gas, consult with a doctor as soon as possible.
• 
Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorised Projector
Dealer or Service Centre to remove the damaged lamp and assure safe operation.
Replacing the Lamp
*Caution*
• 
Do not remove the lamp unit immediately after operation of the projector. The lamp will be
hot and touching it can lead to burn or injury.
• 
Wait at least one hour after the power cord is disconnected to allow the surface of the
lamp unit to fully cool before removing the lamp unit.
• 
If the new lamp does not light after replacement, take your projector to the nearest Sharp
Authorised Projector Dealer or Service Centre for repair. Purchase a replacement lamp
unit of type BQC-PGM20X//1 from your nearest Sharp Authorised Projector Dealer or
Service Centre. Then carefully change the lamp by following the instructions described in
this section. If you wish, you may have the lamp replaced at your nearest Sharp
Authorised Projector Dealer or Service Centre.
Part Number
Description
Price Rank
BQC-PGM20X//1
Lamp Module
CK
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
11
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Removing and Installing the Lamp Unit
Note
• 
Be sure to remove the lamp unit
by the handle. Be sure not to
touch the glass surface of the
lamp unit or the inside of the
projector.
• 
To avoid injury to yourself and
damage to the lamp, be sure to
carefully follow the steps below.
• 
Do not loosen other screws
except for the lamp unit cover and lamp unit. (Only the silver screws are loosened).
• 
Please refer to the installation manual included with the lamp unit.
1. 
 Press “POWER” on the projector to turn off
the power.
• 
Wait until the cooling fan stops.
Warning!
• 
Do not remove the lamp unit from the projector right
after use. The lamp will be very hot and may cause
burn or injury.
2. 
Disconnect the power cord.
• 
Unplug the power cord from the AC socket.
• 
Leave the lamp until it has fully cooled down (about 1 hour). 
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
3. 
Remove the lamp unit cover.
• 
Turn over the projector, and loosen the user
service screw that secures the lamp unit cover.
Then slide the cover in the direction of the arrow.
4. 
 Remove the lamp unit.
• 
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow. 
5. 
Insert the new lamp unit.
• 
Press the lamp unit firmly into the lamp unit
compartment. Fasten the securing screws.
6. 
 Replace the filter/lamp unit cover.
• 
Align the tab on the filter/lamp unit cover (1) and
place it while pressing the tab (2) to close it.
Then tighten the user service screw (3) to
secure the filter/ lamp unit cover.
Note
• 
If the lamp unit and filter/lamp unit cover is not
correctly installed, the power will not turn on,
even if the power cord is connected to the
projector.
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
13
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
 Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1. 
Connect the power cord.
• 
Plug the power cord into the AC socket of the projector.
2. 
Reset the lamp timer.
• 
While pressing simultaneously “ADJ DOWN”, “VOL +” and
“ENTER” on the projector, press “POWER”.
• 
“LAMP 0000H” is displayed, indicating that the lamp timer
is reset.
Note
• 
Make sure to reset the lamp timer only when replacing the
lamp. If you reset the lamp timer and continue to use the
same lamp, this may cause the lamp to become damaged
or explode.
Page of 42