DOWNLOAD Sharp PG-M20S (serv.man15) Service Manual ↓ Size: 164.35 KB | Pages: 2 in PDF or view online for FREE

Model
PG-M20S (serv.man15)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
164.35 KB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Schematic diagram description and waveforms
File
pg-m20s-sm15.pdf
Date

Sharp PG-M20S (serv.man15) Service Manual ▷ View online

100
PG-M20S
PG-M20X
DESCRIPTION OF SCHEMATIC
DIAGRAM
VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose and the above
voltages are measured with a 20k ohm/V tester.
WAVEFORM MEASUREMENT CONDI-
TION:
1. Waveforms at test points are observed at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “
” is omitted.
(K=k
=1000 
, M=M
).
2. All resistors are ± 5%, unless otherwise noted.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are 1/16W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise
noted.
 
C
 : Solid
W
 : Cement
 
S
 : Oxide Film
 
T
 : Special
 
N
 : Metal Coating
CAPACITOR
1. All capacitors are 
µ
F, unless otherwise noted.
(P=pF=
µµ
F).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise
noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
BESCHREIBUNG DES
SCHEMATISCHEN SCHALTPLANS
SPANNUNGSMESSUNGEN:
1. Spannungen an den Prüfpunkten werden bei einer
Netzspannung von 230V gemessen, Signale werden
für die Wartung mit einem Farbbalken-Signal
generator zugeführt, und Spannungen werden mit
einem Meßinstrument (20 k
/V) ermittelt.
SIGNALFORMMESSUNGEN:
1. Die Wellenformen an den Testpunkten werden bei
einer Netzspannung von 230V verfolgt. Signale
werden für die Wartung mit einem Farbbalken-Signal
generator zugeführt.
BEZEICHNUNG DES WIDERSTANDS UND
KONDENSATORS:
WIDERSTAND
1. Die Widerstandseinheit “
” wird weggelassen.
(K=k
=1000 
, M=M
).
2. Alle Widerstände haben ± 5%, sofern nicht anders
angegeben.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. Alle Widerstände haben 1/16W, sofern nicht anders
angegeben.
4. Alle Widerstände sind Kohletyp, sofern nicht anders
angegeben.
 
C
 : Fest
W
 : Zement
 
S
 : Oxidefilm
 
T
 : Spezial
 
N
 : Metallüberzug
KONDENSATOR
1. Die Kapazitätseinheit ist 
µ
F, sofern nicht anders
angegeben.
(P=pF=
µµ
F).
2. Alle Kondensatoren haben 50V, sofern nicht anders
angegeben.
3. Alle Kondensatoren sind Keramiktyp, sofern nicht
anders angegeben.
(ML): Mylar
(TA): Tantal
(PF): Polyprofilm
(ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACEING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH “
  å
 (                  ) ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
ACHTUNG:
bei diesem Schaltplan handelt es sich um den ursprünglichen.
Esönnen daher geringfügige Unterschiede zu dem lhrem bestehen.
SICHERHEITSANMERKUNGEN:
1. VOR DEM AUSWECHSELN VON TEILEN MUSS
U N B E D I N G T   N E T Z S T E C K E R   A U S   D E R
NETZSTECKDOSE GEZOGEN WERDEN.
2. DIE WARMEABLEITER DER HALBLEITER SOLLTEN
BEIM BETRIEB DES CHASSIS ALS MÖGLICHE
URSACHEN VON GEFÄHRLICHEN ELEKTRISCHEN
SCHLÄGEN BETRACHTET WERDEN.
WICHTIGE SICHERHEITSANMERKUNGEN:
MIT “
å
 (                    )BEZEICHNETEN TEILE SIND
BESONDERS WICHTIG FÜR DIE AUFRECHTERHALTUNG
DER SICHERHEIT . BEIM WECHDIESER TEILE SOLLTEN
DIE VORGESCHRIEBENEN TEILE IMMER VERWENDET
WERDEN, UM SOWOHL DIE SICHERHEIT ALS AUCH DIE
LEISTUNG DES GERÄTES AUFRECHTZUERHALTEN.
101
PG-M20S
PG-M20X
WAVEFORMS/WELLENFORMEN
1
SC3101 1-pin
(INPUT CWCTR)
H : 200µ sec/div
V : 6.90V/div
2
SC3101 3-pin
(INPUT CWY2)
H : 200µ sec/div
V : 6.90V/div
3
P9002 1-pin
(FORMAT LAMPEN)
H : 2m sec/div
V : 1.64V/div
4
P9003 2-pin
(FORMAT CWINDEX)
H : 2m sec/div
V : 1.64V/div
5
SC9001 3-pin
(FORMAT CLKIN)
H : 400µ sec/div
V : 870mV/div
6
SC9001 5-pin
(FORMAT HSYNC)
H : 10µ sec/div
V : 880mV/div
7
SC9001 7-pin
(FORMAT VSYNC)
H : 4m sec/div
V : 880mV/div
8
SC9002 17-pin
(FORMAT MTRSICLK)
H : 2µ sec/div
V : 1.44V/div
9
SC9002 25-pin
(FORMAT MTRCLK)
H : 40m sec/div
V : 1.44V/div
0
IC8363 7-pin
(PC-BOARD PCH)
H : 10µ sec/div
V : 840mV/div
q
IC8363 1-pin
(PC-BOARD PCV)
H : 4m sec/div
V : 840mV/div
w
SC3001 3-pin
(INPUT VIDEO)
H : 10µ sec/div
V : 180mV/div
e
SC3001 11-pin
(INPUT S-C)
H : 20µ sec/div
V : 1.44V/div
r
SC3001 8-pin
(INPUT PCGIN2)
H : 10µ sec/div
V : 180mV/div
t
SC3001 20-pin
(INPUT GLPF)
H : 10µ sec/div
V : 230mV/div
y
SC3001 30-pin
(INPUT C-SYNC)
H : 10µ sec/div
V : 840mV/div
Display

Sharp PG-M20S (serv.man15) Service Manual ▷ Download

  • DOWNLOAD Sharp PG-M20S (serv.man15) Service Manual ↓ Size: 164.35 KB | Pages: 2 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp PG-M20S (serv.man15) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp PG-M20S (serv.man15) Projector. Information contained in Sharp PG-M20S (serv.man15) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.