DOWNLOAD Sharp PG-M15 (serv.man3) Service Manual ↓ Size: 1.74 MB | Pages: 17 in PDF or view online for FREE

Model
PG-M15 (serv.man3)
Pages
17
Size
1.74 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service Manual Part 2 - Removing of major parts, Resetting the total lamp timer, Optical adjustment and measuring The optical unit outline (13-29)
File
pg-m15-sm3.pdf
Date

Sharp PG-M15 (serv.man3) Service Manual ▷ View online

22
PG-M15X
PG-M15S
AN-M15T
5. Disassemble Fan Module
5-1. Remove two Hexagon Copper Sticker and detach Assy Fan.
5-2. Remove two screws and detach Exhaust Window Assy.
5-3. Remove two screws and detach Fan and Rubber.
5-1
5-2
5-3
Exhaust Window
Fan Ass'y 
Hexagon Copper Sticker
Rubber
Rubber
Fan
Fan
23
PG-M15X
PG-M15S
AN-M15T
Maintenance Indicators
• The  warning  lights  on  the  projector  indicate  problems
inside the projector.
• There  are  two  warning  lights:  a  TEMPERATURE
WARNING indicator which warns that the projector is too
hot,  and  a  LAMP  REPLACEMENT  indicator  which  lets
you know when to change the lamp.
• If a problem occurs, either the TEMPERATURE WARNING
indicator  or  the  LAMP  REPLACEMENT  indicator  will
illuminate  red.  After  turning  off  the  power,  follow  the
procedures given below.
TEMPERATURE WARNING
indicator
Problem
Maintenance Indicator
Condition
Possible Solution
TEMPERATURE
WARNING
indicator
The internal
temperature is
abnormally high.
• Blocked air intake.
• Relocate the projector to an area with proper
ventilation.
POWER indicator
LAMP REPLACEMENT
indicator
• Cooling fan breakdown.
• Internal circuit failure.
• Take the projector to your nearest Sharp
Authorized Projector Dealer or Service
Center for repair.
• Cooling down.
• Wait until the indicator stops flashing and
turns off.
The indicator flashes in
red.
LAMP
REPLACEMENT
indicator
The lamp does not
illuminate.
• Burnt-out lamp.
• Lamp circuit failure.
• The lamp caga cover is
not securely installed.
• Carefully replace the lamp. 
• Take the projector to your nearest Sharp
Authorized Projector Dealer or Service
Center for repair.
The lamp requires
replacement.
• Lamp has been used for
over 1,400 hours.
• If the TEMPERATURE WARNING indicator illuminates, follow the above possible solutions and then wait until the projector has cooled down
completely before turning the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be triggered, preventing
the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.
RESETTING THE TOTAL  LAMP TIMER
1
Connect the power
cord.
Reset the lamp timer.
1 Press 
KEYSTONE (+) 
and
KEYSTONE (–)
 simultaneously and
ON/OFF
 at the same time.
Plug the power cord into the AC
socket of the projector.
Resetting the lamp timer
“LAMP 0000H” is
displayed, indicating that
the lamp timer is reset.
2
Reset the lamp timer only after replacing the lamp.
»
1
24
PG-M15X
PG-M15S
AN-M15T
Problem
• Lamp has been used for
over 1,400 hours.
• Lamp has been used for
over 1,500 hours.
Possible Solution
• Purchase a replacement lamp unit (lamp
cage/module) of the current type BQC-
PGM15X//1 from your nearest Sharp
Authorized Projector Dealer or Service
Center.
• Replace the lamp. 
If you wish, you may have the lamp
replaced at your nearest Sharp Authorized
Projector Dealer or Service Center.
Condition
The LAMP REPLACEMENT indicator
illuminates red, and “LAMP” will appear in
yellow in the lower-left corner of the picture.
A significant deterioration of the picture and
color quality occurs.
The power will automatically turn off and
the projector will enter standby mode.
“LAMP” will appear in red in the lower-left
corner of the picture, and the power will
turn off.
Lamp
The lamp in this projector operates for approximately 1,500 cumulative hours, depending on the usage environ-
ment. It is recommended that the lamp be replaced after 1,400 cumulative hours of use or when you notice a
significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
Display.
CAUTION
• Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
• As the usage environment can vary significantly, the projector lamp may not operate for 1,500 hours.
• “1,500 hours” above indicates average life span and should be used for reference only. This is different than the warranty period.
• For safety, the power will not be turned on from the fourth time when turning on the power without changing the lamp after use for 1,500
hours.
4
6
Remove the lamp
cage.
5
Insert the new lamp cage.
1
3
Turn off the power.
2
Disconnect the power
cord.
Unplug the power cord from the
AC socket.
Remove the lamp cage
cover.
Attach the lamp cage
cover.
Slide the lamp cage cover in the
direction of the arrow. Then
tighten the user service screws.
Loosen the securing screws on
the lamp cage. Hold the lamp
cage by the handle and pull it
towards you.
Turn over the projector and
loosen the user service screws
that secure the lamp cage cover.
Then lift open the cover in the
direction of the arrow.
Press 
ON/OFF
on the projector
or
POWER
 on the remote
control. Wait until the cooling
fan stops.
Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.
or
25
PG-M15X
PG-M15S
AN-M15T
OPTICAL ADJUSTMENT AND MEASURING
1. Adjustment of Color Wheel Sensor
»
Adjustment needed
1. When the color wheel unit has been replaced.
2. When the color wheel sensor has been replaced.
3. When the optical drive unit has been replaced (If a deviation from normal setting is found).
»
Tools Required
1. Personal computer (run on Windows 95/98)
2. RGB cable
Page of 17
Display