Projector / Service Manual Part 2 - Removing of major parts, Resetting the total lamp timer, Optical adjustment and measuring The optical unit outline (13-29)
File
pg-m15-sm3.pdf
Date

Sharp PG-M15 (serv.man3) Service Manual ▷ View online

20
PG-M15X
PG-M15S
AN-M15T
4. Disassemble Lamp Housing
4-1. Loosen two screws and remove Lamp Cover.
4-2. Loosen three screws and lift Lamp.
4-3. Remove screw and detach Output Air Guide and Output Rubber duct.
4-4. Remove three screws and detach Lamp Housing.
4-5. Remove screw and nut then detach Fan from Lamp Housing.
4-6. Remove four screws and detach Blower Wind Guide from Lamp Housing.
4-7. Remove thermal Fuse from lamp Housing.
Lamp Housing
Lamp Cover
Blower Wind 
Guide
Lamp
Bottom Cover
Output 
Air Guide
Output  
Rubber duct
Spacer
Fan
4-1
4-4
4-5
4-7
4-6
4-3
4-2
Thermal 
Fuse
21
PG-M15X
PG-M15S
AN-M15T
4-8. Remove screw and detach SW PWB unit and Interlock Protection Cover.
4-9. Remove screw and detach Thermal Switch.
4-9
SW PWB unit
Thermal
Switch 70
°
Interlock Protection Cover
Bottom Cover
4-8
4-8
22
PG-M15X
PG-M15S
AN-M15T
5. Disassemble Fan Module
5-1. Remove two Hexagon Copper Sticker and detach Assy Fan.
5-2. Remove two screws and detach Exhaust Window Assy.
5-3. Remove two screws and detach Fan and Rubber.
5-1
5-2
5-3
Exhaust Window
Fan Ass'y 
Hexagon Copper Sticker
Rubber
Rubber
Fan
Fan
23
PG-M15X
PG-M15S
AN-M15T
Maintenance Indicators
• The  warning  lights  on  the  projector  indicate  problems
inside the projector.
• There  are  two  warning  lights:  a  TEMPERATURE
WARNING indicator which warns that the projector is too
hot,  and  a  LAMP  REPLACEMENT  indicator  which  lets
you know when to change the lamp.
• If a problem occurs, either the TEMPERATURE WARNING
indicator  or  the  LAMP  REPLACEMENT  indicator  will
illuminate  red.  After  turning  off  the  power,  follow  the
procedures given below.
TEMPERATURE WARNING
indicator
Problem
Maintenance Indicator
Condition
Possible Solution
TEMPERATURE
WARNING
indicator
The internal
temperature is
abnormally high.
• Blocked air intake.
• Relocate the projector to an area with proper
ventilation.
POWER indicator
LAMP REPLACEMENT
indicator
• Cooling fan breakdown.
• Internal circuit failure.
• Take the projector to your nearest Sharp
Authorized Projector Dealer or Service
Center for repair.
• Cooling down.
• Wait until the indicator stops flashing and
turns off.
The indicator flashes in
red.
LAMP
REPLACEMENT
indicator
The lamp does not
illuminate.
• Burnt-out lamp.
• Lamp circuit failure.
• The lamp caga cover is
not securely installed.
• Carefully replace the lamp. 
• Take the projector to your nearest Sharp
Authorized Projector Dealer or Service
Center for repair.
The lamp requires
replacement.
• Lamp has been used for
over 1,400 hours.
• If the TEMPERATURE WARNING indicator illuminates, follow the above possible solutions and then wait until the projector has cooled down
completely before turning the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be triggered, preventing
the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.
RESETTING THE TOTAL  LAMP TIMER
1
Connect the power
cord.
Reset the lamp timer.
1 Press 
KEYSTONE (+) 
and
KEYSTONE (–)
 simultaneously and
ON/OFF
 at the same time.
Plug the power cord into the AC
socket of the projector.
Resetting the lamp timer
“LAMP 0000H” is
displayed, indicating that
the lamp timer is reset.
2
Reset the lamp timer only after replacing the lamp.
»
1
Page of 17