DOWNLOAD Sharp PG-A10S Service Manual ↓ Size: 801.33 KB | Pages: 46 in PDF or view online for FREE

Model
PG-A10S
Pages
46
Size
801.33 KB
Type
PDF
Document
Handy Guide
Brand
Device
Projector / Version 1.5
File
pg-a10s.pdf
Date

Sharp PG-A10S Handy Guide ▷ View online

Lamp Replacement Procedure
Version 1.5
Issue 04/2006
13
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1. 
Connect the power cord.
• 
Plug the power cord into the AC socket of the projector.
2. 
Reset the lamp timer.
• 
While pressing simultaneously “VOLUME +” and “AUTO
SYNC” on the projector, press “ON” and “VOLUME –“on the
projector.
• 
“LAMP 0000H” is displayed, indicating that the lamp timer is
reset.
Note
• 
Make sure to reset the lamp timer only when replacing the
lamp. If you reset the lamp timer and continue to use the
same lamp, this may cause the lamp to become damaged or
explode.
Maintenance Procedure
Version 1.5
Issue 04/2006
14
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Cleaning the projector
• 
Be sure to unplug the power cord before cleaning the
projector.
• 
The cabinet as well as the operation panel is made of plastic.
Avoid using benzene or thinner, as these can damage the
finish on the cabinet.
• 
Do not use volatile agents such as insecticides on the
projector.
Do not attach rubber or plastic items on the projector for long time.
The effects of some of the agents in the plastic may cause damage to the quality or finish
of the projector.
 
• 
Wipe off dirt gently with a soft flannel cloth.
 
• 
When the dirt is hard to remove, soak a cloth in a
neutral detergent diluted with water, wring the
cloth well and then wipe the projector.
Strong cleaning detergents may discolour, warp
or damage the coating on the projector.
Make sure to test on a small, inconspicuous area
on the projector before using.
Cleaning the lens
• 
Use a commercially available blower or lens cleaning paper
(for glasses and camera lenses) for cleaning the lens. Do not
use any liquid type-cleaning agents, as they may wear off the
coating film on the surface of the lens.
 
• 
As the surface of the lens can easily get damaged, be sure
not to scrape or hit the lens.
Cleaning the exhaust and intake vents
• 
Use a vacuum cleaner to clean dust from the exhaust vent and
the intake vent. 
Maintenance Procedure
Version 1.5
Issue 04/2006
15
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Replacing the Air Filter
• 
This projector is equipped with air filters to
ensure the optimal operating condition of the
projector.
• 
The air filters should be cleaned every 100
hours of use. Clean the filters more often
when the projector is used in a dusty or smoky
location.
 
• 
Ask your nearest Sharp Authorised Projector
Dealer or Service Centre to exchange the filter
(PFILDA008WJZZ) when it is no longer
possible to clean.
1. 
Turn off the power and disconnect the power
cord.
• 
Press “OFF”. Wait until the cooling fan stops.
 
2. 
Remove the filter/lamp unit cover.
• 
Turn the projector over. Loosen the user service
screw (1) that secures the filter/ lamp unit cover.
Pressing the tab (2), remove the filter/lamp unit
cover (3).
3. 
Remove the air filter.
• 
Pick the air filter up with your fingers and lift it out of
the filter/lamp unit cover.
 
Maintenance Procedure
Version 1.5
Issue 04/2006
16
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
4.  Clean the air filter.
• 
Clean the dust off the air filter and cover with a vacuum cleaner
extension hose.
 
5.  Replace the air filter.
• 
Place the air filter underneath the tabs on the
filter/lamp unit cover.
 
6.  Replace the filter/lamp unit cover.
• 
Align the tab on the filter/lamp unit cover (1) and
place it while pressing the tab (2) to close it.
Then tighten the user service screw (3) to
secure the filter/ lamp unit cover.
Note
• 
Be sure the filter/lamp unit cover is securely
installed. The power will not turn on unless it is
correctly installed.
• 
If dust or dirt has collected inside the bottom air
filter (not removable), clean the filter with a
vacuum cleaner extension hose.
Page of 46