Copying Equipment / Details of Each Section - D Scanner Section
File
mx-m950-mx-mm1100-sm16.pdf
Date

Sharp MX-M950 / MX-MM1100 (serv.man16) Service Manual ▷ View online

MX-M1100  SCANNER SECTION  D – 4
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
3)
Remove the screw (a), and remove the SPF glass (b).
4)
Shift the lamp unit (a) to the right, and remove the screw (b).
5)
Disconnect the connector (a). Remove the scanner lamp (b).
6)
Cut the snap band (a), and remove the fixing material (c) from
the scanner lamp (b).
* When attaching, fix it with the snap band. 
* Installation of the scanner lamp.
a)
Install the scanner lamp. Pass the harness (a) through
the guide, then shift the lamp unit (b) to the left edge.
b)
Slightly pull the harness (a), and put a mark (b) with a
pen. 
a
b
c
a
b
a
b
b
a
b
c
b
a
a
b
a
b
MX-M1100  SCANNER SECTION  D – 5
c)
Check to confirm that the harness (a) is shifted by 4mm
when released, and fix it with the harness holder (b).
Install the connector (c).
Check that the harness is not twisted.
b. Sub scanning document size sensor / Main scanning 
document size sensor
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
3)
Remove the screw (a), and remove the dark box cover (b).
4)
Remove the screw (a), and remove the sub scanning docu-
ment size sensor (b).
5)
Remove the screw (a), and remove the plate (b).
6)
Remove the screw (a), and remove the main scanning docu-
ment size sensor (b).
4mm
a
b
c
a
a
b
c
a
a
b
b
a
a
b
a
b
a
a
b
b
MX-M1100  SCANNER SECTION  D – 6
c. CL inverter PWB / AFE PWB / CCD cooling fan / CCD unit
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
3)
Remove the screw (a), and remove the dark box cover (b).
4)
Disconnect the connector (a) and remove the screw (b). Disen-
gage the spacer lock (c), and remove the CL inverter PWB (d). 
5)
Remove the screw (a), and disconnect the connector (b). 
Remove the AFE PWB (c).
6)
Disconnect the connector (a), and Remove the screw (b). 
Remove the plate (c). Remove the screw (d), and remove the 
CCD cooling fan (e).
7)
Disconnect the connector (a), and remove the screw (b). 
Remove the CCD unit (c).
a
a
b
c
a
a
b
b
d
a
c
a
a
b
b
c
b
a
a
b
a
d
d
e
c
c
b
b
b
b
a
a
MX-M1100  SCANNER SECTION  D – 7
d. SCN-Mother PWB
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
3)
Disconnect the connector (a). Remove the screw (b), and pull
out the SCNCNT PWB mounting plate (c).
4)
Remove the screw (a), and remove the plate (b).
5)
Remove the screw (a), and disconnect the connector (b). 
Remove the SCN-Mother PWB (c).
e. SCN-Flash PWB / SCNCNT PWB
1)
Remove the upper cabinet left.
2)
Push the lock (a) to release, and remove the SCN-Flash PWB
(b).
a
a
b
c
a
a
b
c
a
b
a
a
a
a
b
b
b
c
b
b
a
b
Page of 10
Display

Sharp MX-M950 / MX-MM1100 (serv.man16) Service Manual ▷ Download

  • DOWNLOAD Sharp MX-M950 / MX-MM1100 (serv.man16) Service Manual ↓ Size: 3.01 MB | Pages: 10 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp MX-M950 / MX-MM1100 (serv.man16) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-M950 / MX-MM1100 (serv.man16) Copying Equipment. Information contained in Sharp MX-M950 / MX-MM1100 (serv.man16) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.