DOWNLOAD Sharp MX-M364N / MX-565N (serv.man58) Service Manual ↓ Size: 508.76 KB | Pages: 2 in PDF or view online for FREE

Model
MX-M364N MX-565N (serv.man58)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
508.76 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / Rom Upgrade MX-FR45U
File
mx-m364n-mx-565n-sm58.pdf
Date

Sharp MX-M364N / MX-565N (serv.man58) Service Manual / Technical Bulletin ▷ View online

 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
Network 
Modification has been made to enhance the security level for Web access. 
Following features have been added/changed to perform after the log-in with [User 
Authority: users] or [Administrator Authority: admin]  
- Add User Authority (Login Name: User).  
- Change the top screen when accessing the web page to Loin screen. 
Initial values of access authority and password for User and login Administrator are as 
below: 
 
*Access Authority 
User Authority (added): Same as the existing operation which can perform on Top 
screen. 
Administrator Authority: Same as the existing administrator login authority. 
 
*Initial value of password for each authority 
User Authority: users 
Administrator Authority: admin 
 
*Inheritance of the password already set up 
If the passwords for the administrator and user have already set up before updating the 
firmware, the passwords already set up will be inherited after the firmware update.  
(*Passwords for the administrator and user have already set up will not be reset.) 
 
*Enable/disable the additional features 
Those features will be enabled once this firmware is applied. 
For the setting change, those features can be switched between ON and OFF on the 
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device 
Web Page Access Via Password” in “Security Settings” on the top page of Web page. 
 
Checked:   ON (Factory default setting) 
Unchecked: OFF 
*If you upgrade the firmware of machines in field from ROM control No. B01 (or older) 
to this "R control No. C00", the default setting will be "Unchecked: OFF". 
Network 
Enabling display of Machine ID information in MIB 
Network 
Changing factory default for LPD timeout from 0 (infinite) to 90 sec. 
 
*This value won't change after upgrading the firmware in field. 
Network 
Modification of an error of IEEE802.1X authentication via wired LAN 
Network 
Modification of data transmission error which occurred while executing Scan to 
Network Folder for the second time using SMBv2. 
Network 
Correction of MFP lock up 
The phenomenon may occur under the network environment where massive amount 
of packet data flow into MFP while performing such job as broadcasting. 
Network 
Modification of the problem that the machine may lock up if the timeout error occurs 
when performing FSS communication by HTTP communication via Proxy server. 
Printer 
Correction of the problem that the data may be printed in solid black if the processing 
of CMYK 8bit expansion and the processing of halftone process control are performed 
simultaneously. 
10  Printer 
Correction of logo data in black and white output garbled. 
11  Message 
Correction of some messages in Dutch 
 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
Network 
Modification has been made to enhance the security level for Web access. 
Following features have been added/changed to perform after the log-in with [User 
Authority: users] or [Administrator Authority: admin]  
- Add User Authority (Login Name: User).  
- Change the top screen when accessing the web page to Loin screen. 
Initial values of access authority and password for User and login Administrator are as 
below: 
 
*Access Authority 
User Authority (added): Same as the existing operation which can perform on Top 
screen. 
Administrator Authority: Same as the existing administrator login authority. 
 
*Initial value of password for each authority 
User Authority: users 
Administrator Authority: admin 
 
*Inheritance of the password already set up 
If the passwords for the administrator and user have already set up before updating the 
firmware, the passwords already set up will be inherited after the firmware update.  
(*Passwords for the administrator and user have already set up will not be reset.) 
 
*Enable/disable the additional features 
Those features will be enabled once this firmware is applied. 
For the setting change, those features can be switched between ON and OFF on the 
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device 
Web Page Access Via Password” in “Security Settings” on the top page of Web page. 
 
Checked:   ON (Factory default setting) 
Unchecked: OFF 
*If you upgrade the firmware of machines in field from ROM control No. B01 (or older) 
to this "R control No. C00", the default setting will be "Unchecked: OFF". 
Network 
Enabling display of Machine ID information in MIB 
Network 
Changing factory default for LPD timeout from 0 (infinite) to 90 sec. 
 
*This value won't change after upgrading the firmware in field. 
Network 
Modification of an error of IEEE802.1X authentication via wired LAN 
Network 
Modification of data transmission error which occurred while executing Scan to 
Network Folder for the second time using SMBv2. 
Network 
Correction of MFP lock up 
The phenomenon may occur under the network environment where massive amount 
of packet data flow into MFP while performing such job as broadcasting. 
Network 
Modification of the problem that the machine may lock up if the timeout error occurs 
when performing FSS communication by HTTP communication via Proxy server. 
Printer 
Correction of the problem that the data may be printed in solid black if the processing 
of CMYK 8bit expansion and the processing of halftone process control are performed 
simultaneously. 
10  Printer 
Correction of logo data in black and white output garbled. 
11  Message 
Correction of some messages in Dutch 
 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
Network 
Modification has been made to enhance the security level for Web access. 
Following features have been added/changed to perform after the log-in with [User 
Authority: users] or [Administrator Authority: admin]  
- Add User Authority (Login Name: User).  
- Change the top screen when accessing the web page to Loin screen. 
Initial values of access authority and password for User and login Administrator are as 
below: 
 
*Access Authority 
User Authority (added): Same as the existing operation which can perform on Top 
screen. 
Administrator Authority: Same as the existing administrator login authority. 
 
*Initial value of password for each authority 
User Authority: users 
Administrator Authority: admin 
 
*Inheritance of the password already set up 
If the passwords for the administrator and user have already set up before updating the 
firmware, the passwords already set up will be inherited after the firmware update.  
(*Passwords for the administrator and user have already set up will not be reset.) 
 
*Enable/disable the additional features 
Those features will be enabled once this firmware is applied. 
For the setting change, those features can be switched between ON and OFF on the 
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device 
Web Page Access Via Password” in “Security Settings” on the top page of Web page. 
 
Checked:   ON (Factory default setting) 
Unchecked: OFF 
*If you upgrade the firmware of machines in field from ROM control No. B01 (or older) 
to this "R control No. C00", the default setting will be "Unchecked: OFF". 
Network 
Enabling display of Machine ID information in MIB 
Network 
Changing factory default for LPD timeout from 0 (infinite) to 90 sec. 
 
*This value won't change after upgrading the firmware in field. 
Network 
Modification of an error of IEEE802.1X authentication via wired LAN 
Network 
Modification of data transmission error which occurred while executing Scan to 
Network Folder for the second time using SMBv2. 
Network 
Correction of MFP lock up 
The phenomenon may occur under the network environment where massive amount 
of packet data flow into MFP while performing such job as broadcasting. 
Network 
Modification of the problem that the machine may lock up if the timeout error occurs 
when performing FSS communication by HTTP communication via Proxy server. 
Printer 
Correction of the problem that the data may be printed in solid black if the processing 
of CMYK 8bit expansion and the processing of halftone process control are performed 
simultaneously. 
10  Printer 
Correction of logo data in black and white output garbled. 
11  Message 
Correction of some messages in Dutch 
 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
Network 
Modification has been made to enhance the security level for Web access. 
Following features have been added/changed to perform after the log-in with [User 
Authority: users] or [Administrator Authority: admin]  
- Add User Authority (Login Name: User).  
- Change the top screen when accessing the web page to Loin screen. 
Initial values of access authority and password for User and login Administrator are as 
below: 
 
*Access Authority 
User Authority (added): Same as the existing operation which can perform on Top 
screen. 
Administrator Authority: Same as the existing administrator login authority. 
 
*Initial value of password for each authority 
User Authority: users 
Administrator Authority: admin 
 
*Inheritance of the password already set up 
If the passwords for the administrator and user have already set up before updating the 
firmware, the passwords already set up will be inherited after the firmware update.  
(*Passwords for the administrator and user have already set up will not be reset.) 
 
*Enable/disable the additional features 
Those features will be enabled once this firmware is applied. 
For the setting change, those features can be switched between ON and OFF on the 
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device 
Web Page Access Via Password” in “Security Settings” on the top page of Web page. 
 
Checked:   ON (Factory default setting) 
Unchecked: OFF 
*If you upgrade the firmware of machines in field from ROM control No. B01 (or older) 
to this "R control No. C00", the default setting will be "Unchecked: OFF". 
Network 
Enabling display of Machine ID information in MIB 
Network 
Changing factory default for LPD timeout from 0 (infinite) to 90 sec. 
 
*This value won't change after upgrading the firmware in field. 
Network 
Modification of an error of IEEE802.1X authentication via wired LAN 
Network 
Modification of data transmission error which occurred while executing Scan to 
Network Folder for the second time using SMBv2. 
Network 
Correction of MFP lock up 
The phenomenon may occur under the network environment where massive amount 
of packet data flow into MFP while performing such job as broadcasting. 
Network 
Modification of the problem that the machine may lock up if the timeout error occurs 
when performing FSS communication by HTTP communication via Proxy server. 
Printer 
Correction of the problem that the data may be printed in solid black if the processing 
of CMYK 8bit expansion and the processing of halftone process control are performed 
simultaneously. 
10  Printer 
Correction of logo data in black and white output garbled. 
11  Message 
Correction of some messages in Dutch 
 
 
 
Display

Sharp MX-M364N / MX-565N (serv.man58) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-M364N / MX-565N (serv.man58) Service Manual ↓ Size: 508.76 KB | Pages: 2 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-M364N / MX-565N (serv.man58) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-M364N / MX-565N (serv.man58) Copying Equipment. Information contained in Sharp MX-M364N / MX-565N (serv.man58) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.