Sharp MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man2) Handy Guide ▷ View online
17
Test Simulations
1.Entering the simulation mode
Perform the following procedure to enter the simulation mode.
Main code [START] key then Sub code [START] key
2. Cancelling the simulation mode
When the clear all key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the screen
returns to the sub code entering display.
After cancelling the simulation mode, be sure to turn OFF/ON the power and check
the operation.
Note: If the machine is terminated by a jam error or paper empty during copying in
the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but sample values.
When the interruption key is pressed, the process is interrupted and the screen
returns to the sub code entering display.
After cancelling the simulation mode, be sure to turn OFF/ON the power and check
the operation.
Note: If the machine is terminated by a jam error or paper empty during copying in
the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but sample values.
Main Sub
Contents
01
01
Used to check the operation of the scanner unit and its control
circuit.
circuit.
02
Used to check the operation of sensor and detector in the scanning
(read) section and the related circuit.
(read) section and the related circuit.
02
01
Used to check the operation of the RSPF unit and the related
circuit.
circuit.
02
Used to check the operation of sensors and detectors in the RSPF
unit and the related circuit.
unit and the related circuit.
03
Used to check the operation of the loads in the RSPF unit and the
control circuits.
control circuits.
03
02
Used to check the operation of sensor and detector in the finisher
and the related circuit.
and the related circuit.
03
Used to check the operation of the load in the finisher and the
control circuit.
control circuit.
10
Used to make each adjustment of the finisher.
18
Main
Sub
Contents
03
11
Used to check the shifter operation.
Reciprocating operations are continuously performed or the home
position is checked. (The shifter is shifted to the home position or
moved in one way by the specified steps.)
Reciprocating operations are continuously performed or the home
position is checked. (The shifter is shifted to the home position or
moved in one way by the specified steps.)
04
02
Used to check the operation of sensor and detector in the option
tray and the related circuit.
tray and the related circuit.
03
Used to check the operation of the load in the option tray and the
control circuit.
control circuit.
05
01
Used to check the operation of the display (LED), LCD in the
operation panel, and control circuit.
operation panel, and control circuit.
02
Used to check the operation of the heater lamp and the control
circuit.
circuit.
03
Used to check the operation of the copy lamp and the control
circuit.
circuit.
06
01
Used to check the operation of the loads (clutches and solenoids)
in the paper transport system and the control circuit.
in the paper transport system and the control circuit.
02
Used to check the operation of each fan motor and its control
circuit.
circuit.
07
01
Used to set the aging operation conditions.
06
Used to set the cycle of intermittent aging.
08
Used to set the display of the warm-up time.
08
01
Used to check and adjust the operation of the developing bias
voltage in each copy mode and the control circuit.
voltage in each copy mode and the control circuit.
02
Used to check and adjust the operation of the main charger grid
voltage in each copy mode and the control circuit.
voltage in each copy mode and the control circuit.
10
Used to check and adjust the operation of the developing bias
voltage in each printer mode and the control circuit.
voltage in each printer mode and the control circuit.
11
Used to check and adjust the operation of the main charger grid
voltage in each printer mode and the control circuit.
voltage in each printer mode and the control circuit.
13
Used to check and adjust the operation of the developing bias
voltage in FAX mode and the control circuit.
voltage in FAX mode and the control circuit.
14
Used to check and adjust the operation of the main charger grid
voltage in FAX mode and the control circuit.
voltage in FAX mode and the control circuit.
09
01
Used to check and adjust the operation of the load (motor) in the
duplex section and the control circuit.
duplex section and the control circuit.
04
Duplex motor RPM setting
05
Used to adjust the timing of switching from normal rotation to
reverse rotation or from reverse rotation to normal rotation of the
duplex motor.
reverse rotation or from reverse rotation to normal rotation of the
duplex motor.
10
0
Used to check the operation of the toner motor and its control
circuit.
circuit.
14
0
Used to cancel excluding the self-diag U2/PF troubles.
16
0
Used to cancel the self-diag U2 trouble.
17
0
Used to cancel the self diag “PF” trouble.
21
01
Used to set the maintenance cycle.
22
01
Used to check the counter value of each section.
19
Main
Sub
Contents
22
02
Used to check the total numbers of misfeed and troubles. (When
the number of misfeed is considerably great, it is judged as
necessary for repair. The misfeed rate is obtained by dividing this
count value with the total counter value.)
the number of misfeed is considerably great, it is judged as
necessary for repair. The misfeed rate is obtained by dividing this
count value with the total counter value.)
03
Used to check the misfeed positions and the number of misfeed at
each position. (When the number of misfeed is considerably great,
it can be judged as necessary for repair.)
each position. (When the number of misfeed is considerably great,
it can be judged as necessary for repair.)
04
Used to check the total trouble (self diag) history.
05
Used to check the ROM version of each unit (section).
06
Used to print each key operator setting, the account information,
and the machine adjustment values.
and the machine adjustment values.
07
Used to display of the administrator password.
08
Used to display the original, staple counter.
09
Used to check the number of use of each paper feed section. (the
number of prints)
number of prints)
10
Used to check the system configuration.
11
Used to display the FAX send/receive counter (FAX reception and
print counter).
print counter).
12
Used to check the misfeed positions and the number of misfeed at
each position. (When the number of misfeed is considerably great,
it can be judged as necessary for repair.)
each position. (When the number of misfeed is considerably great,
it can be judged as necessary for repair.)
13
Used to display the CRUM type.
19
Used to display the scanner counter in the network scanner mode.
24
01
Used to clear the misfeed counter, the misfeed history, the trouble
counter, and the trouble history. (The counters are cleared after
completion of maintenance.)
counter, and the trouble history. (The counters are cleared after
completion of maintenance.)
02
Used to clear the number of use (the number of prints) of each
paper feed section.
paper feed section.
03
Used to clear the number usage data of the stapler, RSPF, and
scanning.
scanning.
04
Used to reset the maintenance counter.
05
Used to reset the developer counter. (The developer counter of the
DV unit which is installed is reset.)
DV unit which is installed is reset.)
06
Used to clear the copy counter.
07
Used to clear the OPC drum (membrane decrease) correction
counter. (This simulation is executed when the OPC drum is
replaced.)
counter. (This simulation is executed when the OPC drum is
replaced.)
09
Used to clear the printer counter and other counters.
10
FAX counter data clear
15
Used to clear the scanner counter in the network scanner mode.
25
01
Used to check the operation of the main drive (excluding the
scanner section) and to check the operation of the toner
concentration sensor. (The toner concentration sensor output can
be monitored.)
scanner section) and to check the operation of the toner
concentration sensor. (The toner concentration sensor output can
be monitored.)
20
Main
Sub
Contents
25
02
Used to make the initial setting of toner concentration when
replacing developer.
replacing developer.
26
01
Used to set whether the job separator is installed or not. (Since this
cannot be detected by hardware detection, it is set in this
simulation.)
cannot be detected by hardware detection, it is set in this
simulation.)
02
Used to set whether the automatic detection of paper size is made
or not.
or not.
03
Used to set the specifications of the auditor. Setting must be made
depending on the use condition of the auditor.
depending on the use condition of the auditor.
05
Used to set the count mode of the total counter and the
maintenance counter.
maintenance counter.
06
Used to set the specifications depending on the destination.
10
Network scanner trial mode setting
12
Used to input the Software Key for E-MAIL RIC.
14
Used to input the Software Key for the PS extension kit.
18
Used to set enable/disable of toner save operation.
22
Used to set the specification (language display) for the destination.
30
Used to set ON/OFF of the heater lamp slow-up control conforming
to the CE mark control.
to the CE mark control.
35
Used to set whether the same continuous troubles are displayed as
one trouble or the series of troubles with SIM 22-4 when the same
troubles occur continuously.
one trouble or the series of troubles with SIM 22-4 when the same
troubles occur continuously.
36
Used to set whether the machine is stopped or not when the
maintenance counter life is expired.
maintenance counter life is expired.
50
Used to set ON/OFF of the black and white reversion function.
56
Gamma life correction setting
57
Used to set the model code.
60
Used to set enable/disable of the FAX mode key when FAX is not
installed. (When FAX is installed, the FAX mode is enabled
regardless of this setup.)
installed. (When FAX is installed, the FAX mode is enabled
regardless of this setup.)
69
Toner near end setting
71
In the power save time setting, the pre-heat (preheat mode setting)
and the auto power shut off time can be set to the short time setup
(pre-heat: 1 min, auto power shut off: 4 min) and the long time
setup (pre-heat: 15min, auto power shut off: 60min).
and the auto power shut off time can be set to the short time setup
(pre-heat: 1 min, auto power shut off: 4 min) and the long time
setup (pre-heat: 15min, auto power shut off: 60min).
72
The letterhead support is set. When “Letterhead paper setting” is
selected, the set value of SIM 26-46 (Image output direction
setting) is set to “Setting Enable” accordingly.
selected, the set value of SIM 26-46 (Image output direction
setting) is set to “Setting Enable” accordingly.
27
01
Used to set PC/MODEM communication trouble (U7-00) detection
Yes/No.
Yes/No.
02
Sender’s registration number/HOST server TEL number.
04 Function
setting
05
Used to set the tag number
07
FSS function setting
09
FSS function adjustment
10
Trouble precognition history clear
14
FSS connection test setting
Click on the first or last page to see other MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man2) service manuals if exist.