TECHNICAL BULLETIN
SERVICE PARTS SETTINGS AND MOUNTING
PROCEDURE
PROCEDURE
S/I No. DCE-851 issued on February 7th 2012 has been revised because the new
machines have been added to the supported models. According to this change, the
service parts mounting procedure for the additional models have also been added to this
information.
1.Model Name: MX-M182/M182D/M202D/M232D
2.General:
The service parts used for connecting the coin vendor or auditor to the models above
have been set. So when connecting the coin vendor or auditor to one of these models,
procure the following service parts:
1) All service parts for connecting the coin vendor or auditor:
Parts Name
Parts Code
Qty
Price Rank
CV_AUD I/F PWB UNIT
CPWBN0275QS31
1
BT
CV_AUD Harness
DHAI-0704QSPZ
1
AR
Screw (M3x6)
XHBS730P06000
2
AC
Band LBNDJ0037FCZ1
1
AA
CV_AUD I/F PWB UNIT (CPWBN0275QS31) CV_AUD Harness (DHAI-0704QSPZ)
2)
Mounting
Procedure:
Refer to the Service Parts Mounting Procedure as attached.
Sharp Electronics (UK) Ltd., Document Systems Support
2/5
CV_AUD I/F Service Parts Mounting Procedure
1. Model Name: MX-M182/M182D/M202D/M232D
AR-5618/5618D/5618N/5620/5620D/5620N/5623/5623D/5623N
AR-X180/X200/X200D/X230N
(1) Remove the rear cabinet from the main unit.
(2) Fix the CV_AUD I/F PWB at the location shown on the photo below with screws.
* If only one of Coin Vendor and Auditor is used, it is all right with the unused side disconnected
For connection to
Auditor *
For connection to
MCU PWB
For connection to
Coin Vendor *
Location for CV_AUD I/F
PWB UNIT to be fixed
Tighten it at these 2 locations with screws.
Sharp Electronics (UK) Ltd., Document Systems Support
3/5
(3) Connect the harness.
(4) Close the rear cabinet, the end of mounting procedure.
(5) Validate the Coin Vendor with use of the function settings.
Change the setting of SIM26-3 to “1” to activate the coin vendor.
When the bypass tray needs to be used, change the setting of SIM26-31 to “1”
to use the bypass tray.
Tie with the mirror-motor harness.
Connect DHAI-0704QSPZ to CN133
Connect to Coin Vendor/Auditor (outside the machine)
MCU PWB
Sharp Electronics (UK) Ltd., Document Systems Support
4/5
2. Model Name: AR-6020/6023/6020D/6023D/6020N/6023N/6026N/6031N
(1) Remove the rear cabinet from the main unit.
(2) Fix the CV_AUD I/F PWB at the location shown on the photo below with screws.
* If only one of Coin Vendor and Auditor is used, it is all right with the unused side disconnected.
For connection to
Auditor *
For connection to
MCU PWB
For connection to
Coin Vendor *
Tighten it at these 2 locations with screws.
Location for CV_AUD I/F
PWB UNIT to be fixed
Display