MX-M200D
SIGNAL NAME LIST
– 84 –
Sensor
/LFTHP
Job separator home 
position sensor
Job separator home 
position sensor
Home 
position
CN26
19
MCU
Sensor
/TRAY_D
Tray full space sensor 
(Transmission type)
Detects full space of paper 
tray
Paper no 
empty
CN26
18
MCU
Sensor
/TRAY_FULL
Upper tray full space 
sensor 
(Transmission type)
Detects full space of paper 
tray
Full
CN26
17
MCU
Sensor
/JOBS_DLD
Job separator lower limit 
position detection switch 
(SW)
Detects lower limit position 
of job separator
Detection
CN26
8
MCU
Sensor
SFTHP
Shifter home position 
sensor (Transmission 
type)
Home position sensor of 
shifter
Home 
position
CN26
4
MCU
Sensor
/SPFPOUT
SPF paper exit sensor 
(Transmission type)
Paper pass sensor of 
document exit in SPF
Paper no 
empty
CN9
19
MCU
Sensor
SPFPAPER
SPF paper pass sensor 
(Transmission type)
Paper pass sensor of SPF
Paper no 
empty
CN9
25
MCU
Sensor
MHPS
Mirror home position 
sensor 
(Transmission type)
Home position sensor of 
scanner mirror unit
Home 
position
CN10
2
MCU
Sensor
CASETTE
1st tray open/close 
switch (SW)
Detects open/close of 1st 
tray
OPEN
CLOSE
CN14
1
MCU
Sensor
PIN
Paper entry sensor 
(Transmission type)
Detects paper transport
Paper no 
empty
CN20
2
MCU
Sensor
HPEMPTY
Manual paper tray paper 
empty sensor 
(Transmission type)
Detects manual paper
Paper no 
empty
CN17
2
MCU
Sensor
CPEMPTY
1st tray paper empty 
sensor 
(Transmission type)
Detects paper empty of 
1st tray
Paper no 
empty
CN18
2
MCU
Sensor
RTH_IN
Fusing thermistor 
(Thermistor)
Thermistor signal for 
fusing temperature 
detection
CN25
1
MCU
Analog
Sensor
OCCOVER
OC cover open/close 
sensor 
(Transmission type)
Detects open/close of OC 
cover and SPF
CLOSE
OPEN
CN47
2
MCU
Operation 
panel
/PANEL_RST
Operation panel hard 
reset
Resets LCD PWB
Reset
CN704
8
MCU
Operation 
panel
/OPUWU
Operation panel activate 
request signal
Activate request signal of 
return from energy-saving 
by user operation
Activate 
request
CN704
3
MCU
Dehumi-
difying
/DHROFF
Dehumidifying heater 
control
Controls ON/OFF of the 
dehumidifying heater
ON
CN32
4
MCU
Solenoid
SPFRSOL
SPF pressure release 
solenoid
SPF pressure release 
solenoid
ON
CN9
9
MCU
Solenoid
SPFGSOL
SPF gate solenoid
SPF gate solenoid
ON
CN9
22
MCU
Solenoid
SPFPSOL
SPF pickup solenoid
SPF pickup solenoid
ON
CN9
10
MCU
Solenoid
/HPSOL
Manual paper feed 
solenoid
Manual paper feed 
solenoid
ON
CN21
2
MCU
Solenoid
/PSRSOL
Resist roller solenoid
Resist roller solenoid
ON
CN23
2
MCU
Solenoid
/CPSOL
1st tray paper feed 
solenoid
Paper feed solenoid for 1st 
tray
ON
CN22
2
MCU
Solenoid
(PSOL1)
2nd tray paper feed 
solenoid
Paper feed solenoid for 
2nd tray
ON
CN36
3
MCU
Solenoid
(FSOL1)
2nd tray transport 
solenoid
Transport solenoid for 2nd 
tray
ON
CN36
4
MCU
Solenoid
(PSOL2)
3rd tray paper feed 
solenoid
Paper feed solenoid for 
3rd tray
ON
CN36
5
MCU
Solenoid
(FSOL2)
3rd tray transport 
solenoid
Transport solenoid for 3rd 
tray
ON
CN36
6
MCU
Solenoid
(PSOL3)
4th tray paper feed 
solenoid
Paper feed solenoid for 
4th tray
ON
CN36
7
MCU
Solenoid
(FSOL3)
4th tray transport 
solenoid
Transport solenoid for 4th 
tray
ON
CN36
8
MCU
Power 
supply
3.3VIN
3.3V logic power
Power
CN3
14
MCU
Category
Signal name
Name(Type)
Function/Operation
Connector level
Connector 
No.
Pin 
No.
PWB 
name
Note
"L"
"H"
MX-M200D
SIGNAL NAME LIST
– 85 –
Power 
supply
5VEN
5V energy-saving power
Power
CN3
15
MCU
Power 
supply
5VIN
5V power
Power (OFF when shutoff)
CN3
17
MCU
Power 
supply
24VIN
24V power
Power (OFF when shutoff)
CN3
19
MCU
Power 
supply
24V1(DSWS)
Interlock circuit power
Power via interlock SW
CN28
3
MCU
Power 
supply 
control
(/POFF)
Power off signal
Controls to power shutoff 
mode
shutoff
CN3
18
MCU
Power 
supply 
control
FW
AC zero cross signal
AC zero cross detection 
signal
CN3
21
MCU
100/
120Hz
Power 
supply 
control
/PR
Power relay control
Controls ON/OFF of the 
power relay of power UN
ON
CN3
23
MCU
Power 
supply 
control
HLOUT
Heater control
Controls ON/OFF of fusing 
heater
OFF
ON
CN3
24
MCU
Fan
PSFMOUT
Power/Ozone fan
Drives power fan and 
ozone fan
Stop
Driving
CN3
12
MCU
Fan
/PSFMCNT
Power fan speed
Controls power fan speed
CN3
13
MCU
Two-
speed 
control
Fan
VFMOUT
Paper exit fan
Drives paper exit fan
Stop
Driving
CN26
6
MCU
Fan
/VFMCNT
Paper exit fan speed
Controls paper exit fan 
speed
CN26
5
MCU
Two-
speed 
control
Fan
(OZNFN_LO
CK)
Ozone fan lock
Detects lock of ozone fan
Lock 
detection
CN115
2
MCU
Motor
/PMD
Polygon motor 
(Brushless motor)
Controls polygon motor 
(LSU) driving
Driving
Stop
CN703
10
MCU
Motor
/PMRDY
Polygon motor ready
Detects standby of 
polygon motor
Standby
Stop
CN703
11
MCU
Motor
/PMCLK
Polygon motor clock 
(CL)
Polygon motor driving 
clock
CN703
12
MCU
Motor
(SPMT0)
(SPMT1)
(SPMT2)
(SPMT3)
SPF motor dirving signal 
(Four-phase stepping 
motor)
Drives SPF motor driver 
(SPF PWB)
CN9
MCU
Constant 
voltage
Motor
OUT_A+ 
OUT_B+ 
OUT_A- 
OUT_B-
Mirror motor 
(Bipolar stepping motor)
Drives mirror motor
CN12
MCU
Constant 
current 
motor
Motor
/DMT_0 
/DMT_1 
/DMT_2 
/DMT_3
Duplex motor 
(Four-phase stepping 
motor)
Dirves duplex motor
CN13
MCU
Constant 
voltage
Motor
/MMD
Main motor 
(Brushless motor)
Main motor drive control
Drive
Stop
CN24
4
MCU
Motor
/MMRDY
Main motor ready
Detects main motor 
standby
Standby
Stop
CN24
3
MCU
Motor
TMA_O 
TMB_O
Toner motor 
(Synchronous motor)
Drives toner motor
CN30
MCU
Motor
(JOBS_MT0) 
(JOBS_MT1) 
(JOBS_MT2) 
(JOBS_MT3)
Job separator motor 
driving signal (Four-
phase stepping motor)
Drives job separator motor 
dirver (TRAY PWB)
CN26
MCU
Constant 
voltage
Motor
(SJMT0) 
(SJMT1) 
(SJMT2) 
(SJMT3)
Shifter motor driving 
signal (Four-phase 
stepping motor)
Drives shifter motor driver 
(TRAY PWB)
CN26
MCU
Category
Signal name
Name(Type)
Function/Operation
Connector level
Connector 
No.
Pin 
No.
PWB 
name
Note
"L"
"H"
 
No part of this publication may be reproduced,
stored in a retrieval system, or transmitted in
any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without
prior written permission of the publisher.
COPYRIGHT 
© 
XXXX BY
 SHARP CORPORATION
ALL RIGHTS RESERVED.
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder.
The alphabet following the LF mark shows the kind of lead-free solder.
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread.
Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since  the  melting  point  of  lead-free  solder  thread  is  about  40°C  higher  than  that  of  conventional lead  solder  thread,  the  use  of  the 
exclusive-use  soldering  iron  is  recommendable.
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering 
capacity is inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land 
separation or may exceed the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when 
completion of soldering is confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If  different-kind  solder  remains  on  the  soldering  iron  tip,  it  is  melted  together  with  lead-free  solder. To  avoid  this,  clean  the  soldering  iron 
tip  after  completion  of  soldering  work.
If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.
Example:
5mm
Lead-Free
Solder composition
code (Refer to the
table at the right.)
<Solder composition code of lead-free solder> 
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
LEAD-FREE SOLDER
 
(Danish)
ADVARSEL !
Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandoren.
(English)
Caution !
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according to manufacturer’s instructions.
(Finnish)
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
(French)
ATTENTION
Il y a danger d’explosion s’ il y a remplacement incorrect
de la batterie. Remplacer uniquement avec une batterie du
même type ou d’un type équivalent recommandé par
le constructeur.
Mettre au rebut les batteries usagées conformément aux
instructions du fabricant.
(Swedish)
VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens
instruktion.
(German)
Achtung
Explosionsgefahr bei Verwendung inkorrekter Batterien.
Als Ersatzbatterien dürfen nur Batterien vom gleichen Typ oder
vom Hersteller empfohlene Batterien verwendet werden.
Entsorgung der gebrauchten Batterien nur nach den vom
Hersteller angegebenen Anweisungen.
(For USA, CANADA)
“BATTERY DISPOSAL”
THIS PRODUCT CONTAINS A LITHIUM PRIMARY
(MANGANESS DIOXIDE) MEMORY BACK-UP BATTERY
THAT MUST BE DISPOSED OF PROPERLY. REMOVE THE
BATTERY FROM THE PRODUCT AND CONTACT YOUR
LOCAL ENVIRONMENTAL AGENCIES FOR INFORMATION
ON RECYCLING AND DISPOSAL OPTIONS.
“TRAITEMENT DES PILES USAGÉES”
CE PRODUIT CONTIENT UNE PILE DE SAUVEGARDE DE
MÉMOIRE LITHIUM PRIMAIRE (DIOXYDE DE MANGANÈSE)
QUI DOIT ÊTRE TRAITÉE CORRECTEMENT. ENLEVEZ LA
PILE DU PRODUIT ET PRENEZ CONTACT AVEC VOTRE
AGENCE ENVIRONNEMENTALE LOCALE POUR DES
INFORMATIONS SUR LES MÉTHODES DE RECYCLAGE ET
DE TRAITEMENT.
CAUTION FOR BATTERY REPLACEMENT
CAUTION FOR BATTERY DISPOSAL
Page of 89
Display

Click on the first or last page to see other MX-M160 / MX-M160D / MX-M160DK (serv.man3) service manuals if exist.