MX-FX13  FAX SOFT SWITCH  4 - 35
104
1-8
Scanning 
magnification ratio 
adjustment OC 
(Main scanning)
105
1-8
Scanning 
magnification ratio 
adjustment OC (Sub 
scanning)
Binary input
Setting range -12.7% to +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
Bit No.
Setting 
value
1 2 3 4 5 6 7 8
1 0 0 0 0 0 0 0 0.0%
1 0 0 0 0 0 0 1 -0.1%
1 0 0 0 0 0 1 0 -0.2%
1 0 0 0 0 0 1 1 -0.3%
1 0 0 0 0 1 0 0 -0.4%
1 0 0 0 0 1 0 1 -0.5%
1 0 0 0 0 1 1 0 -0.6%
1 0 0 0 0 1 1 1 -0.7%
1 0 0 0 1 0 0 0 -0.8%
1 0 0 0 1 0 0 1 -0.9%
1 0 0 0 1 0 1 0 -1.0%
1 0 0 0 1 0 1 1 -1.1%
1 0 0 0 1 1 0 0 -1.2%
1 0 0 0 1 1 0 1 -1.3%
1 0 0 0 1 1 1 0 -1.4%
1 0 0 0 1 1 1 1 -1.5%
1 0 0 1 0 0 0 0 -1.6%
1 0 0 1 0 0 0 1 -1.7%
1 0 0 1 0 0 1 0 -1.8%
1 0 0 1 0 0 1 1 -1.9%
1 0 0 1 0 1 0 0 -2.0%
1 0 0 1 0 1 0 1 -2.1%
1 0 0 1 0 1 1 0 -2.2%
1 0 0 1 0 1 1 1 -2.3%
1 0 0 1 1 0 0 0 -2.4%
1 0 0 1 1 0 0 1 -2.5%
1 0 0 1 1 0 1 0 -2.6%
1 0 0 1 1 0 1 1 -2.7%
1 0 0 1 1 1 0 0 -2.8%
1 0 0 1 1 1 0 1 -2.9%
1 0 0 1 1 1 1 0 -3.0%
1 0 0 1 1 1 1 1 -3.1%
1 0 1 0 0 0 0 0 -3.2%
1 0 1 0 0 0 0 1 -3.3%
1 0 1 0 0 0 1 0 -3.4%
1 0 1 0 0 0 1 1 -3.5%
1 0 1 0 0 1 0 0 -3.6%
1 0 1 0 0 1 0 1 -3.7%
1 0 1 0 0 1 1 0 -3.8%
1 0 1 0 0 1 1 1 -3.9%
1 0 1 0 1 0 0 0 -4.0%
1 0 1 0 1 0 0 1 -4.1%
1 0 1 0 1 0 1 0 -4.2%
1 0 1 0 1 0 1 1 -4.3%
1 0 1 0 1 1 0 0 -4.4%
1 0 1 0 1 1 0 1 -4.5%
1 0 1 0 1 1 1 0 -4.6%
1 0 1 0 1 1 1 1 -4.7%
1 0 1 1 0 0 0 0 -4.8%
1 0 1 1 0 0 0 1 -4.9%
1 0 1 1 0 0 1 0 -5.0%
1 0 1 1 0 0 1 1 -5.1%
1 0 1 1 0 1 0 0 -5.2%
1 0 1 1 0 1 0 1 -5.3%
1 0 1 1 0 1 1 0 -5.4%
1 0 1 1 0 1 1 1 -5.5%
1 0 1 1 1 0 0 0 -5.6%
1 0 1 1 1 0 0 1 -5.7%
1 0 1 1 1 0 1 0 -5.8%
1 0 1 1 1 0 1 1 -5.9%
1 0 1 1 1 1 0 0 -6.0%
1 0 1 1 1 1 0 1 -6.1%
1 0 1 1 1 1 1 0 -6.2%
1 0 1 1 1 1 1 1 -6.3%
1 1 0 0 0 0 0 0 -6.4%
1 1 0 0 0 0 0 1 -6.5%
1 1 0 0 0 0 1 0 -6.6%
1 1 0 0 0 0 1 1 -6.7%
1 1 0 0 0 1 0 0 -6.8%
1 1 0 0 0 1 0 1 -6.9%
1 1 0 0 0 1 1 0 -7.0%
1 1 0 0 0 1 1 1 -7.1%
1 1 0 0 1 0 0 0 -7.2%
1 1 0 0 1 0 0 1 -7.3%
1 1 0 0 1 0 1 0 -7.4%
1 1 0 0 1 0 1 1 -7.5%
1 1 0 0 1 1 0 0 -7.6%
1 1 0 0 1 1 0 1 -7.7%
1 1 0 0 1 1 1 0 -7.8%
1 1 0 0 1 1 1 1 -7.9%
1 1 0 1 0 0 0 0 -8.0%
1 1 0 1 0 0 0 1 -8.1%
1 1 0 1 0 0 1 0 -8.2%
1 1 0 1 0 0 1 1 -8.3%
1 1 0 1 0 1 0 0 -8.4%
1 1 0 1 0 1 0 1 -8.5%
Bit No.
Setting 
value
1 2 3 4 5 6 7 8
1 1 0 1 0 1 1 0 -8.6%
1 1 0 1 0 1 1 1 -8.7%
1 1 0 1 1 0 0 0 -8.8%
1 1 0 1 1 0 0 1 -8.9%
1 1 0 1 1 0 1 0 -9.0%
1 1 0 1 1 0 1 1 -9.1%
1 1 0 1 1 1 0 0 -9.2%
1 1 0 1 1 1 0 1 -9.3%
1 1 0 1 1 1 1 0 -9.4%
1 1 0 1 1 1 1 1 -9.5%
1 1 1 0 0 0 0 0 -9.6%
1 1 1 0 0 0 0 1 -9.7%
1 1 1 0 0 0 1 0 -9.8%
1 1 1 0 0 0 1 1 -9.9%
1 1 1 0 0 1 0 0 -10.0%
1 1 1 0 0 1 0 1 -10.1%
1 1 1 0 0 1 1 0 -10.2%
1 1 1 0 0 1 1 1 -10.3%
1 1 1 0 1 0 0 0 -10.4%
1 1 1 0 1 0 0 1 -10.5%
1 1 1 0 1 0 1 0 -10.6%
1 1 1 0 1 0 1 1 -10.7%
1 1 1 0 1 1 0 0 -10.8%
1 1 1 0 1 1 0 1 -10.9%
1 1 1 0 1 1 1 0 -11.0%
1 1 1 0 1 1 1 1 -11.1%
1 1 1 1 0 0 0 0 -11.2%
1 1 1 1 0 0 0 1 -11.3%
1 1 1 1 0 0 1 0 -11.4%
1 1 1 1 0 0 1 1 -11.5%
1 1 1 1 0 1 0 0 -11.6%
1 1 1 1 0 1 0 1 -11.7%
1 1 1 1 0 1 1 0 -11.8%
1 1 1 1 0 1 1 1 -11.9%
1 1 1 1 1 0 0 0 -12.0%
1 1 1 1 1 0 0 1 -12.1%
1 1 1 1 1 0 1 0 -12.2%
1 1 1 1 1 0 1 1 -12.3%
1 1 1 1 1 1 0 0 -12.4%
1 1 1 1 1 1 0 1 -12.5%
1 1 1 1 1 1 1 0 -12.6%
1 1 1 1 1 1 1 1 -12.7%
Bit No.
Setting 
value
1 2 3 4 5 6 7 8
MX-FX13  FAX SOFT SWITCH  4 - 36
106
1-4
Scan effective image 
area (SPF), Sub 
scanning, Lead edge 
image loss
Binary input
Setting range: -56 to +56 lines  1step = 8 lines
For Bit No., refer to the table of SW102 (1 - 4).
0 line
0
0
0
0
5-8
Scan effective image 
area (SPF), Sub 
scanning, Rear edge 
image loss
Binary input
Setting range: -14 to +14 lines  1step = 2 lines
For Bit No., refer to the table of SW102 (5 - 8).
0 line
0
0
0
0
107
1-4
Scan effective image 
area (SPF), Main 
scanning, Left edge 
image loss
Binary input
Setting range: -56 to +56 dots  1step = 8 dots
For Bit No., refer to the table of SW103 (1 - 4).
(However, the unit of a set value is dots.)
0 dot
0
0
0
0
5-8
Scan effective image 
area (SPF), Main 
scanning, Right edge 
image loss
Binary input
Setting range: -56 to +56 dots  1step = 8 dots
For Bit No., refer to the table of SW103 (1 - 4).
(However, the unit of a set value is dots.)
0 dot
0
0
0
0
108
1-8
Scanning 
magnification ratio 
adjustment SPF 
(Main scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
109
1-8
Scanning 
magnification ratio 
adjustment SPF (Sub 
scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
110
1-4
Scan effective image 
area (SPF) back 
surface, Sub 
scanning, Lead edge 
image loss
Binary input
Setting range: -56 to +56 lines  1step = 8 lines
For Bit No., refer to the table of SW102 (1 - 4).
0 line
0
0
0
0
5-8
Scan effective image 
area (SPF) back 
surface, Sub 
scanning, Rear edge 
image loss
Binary input
Setting range: -14 to +14 lines  1step = 2 lines
For Bit No., refer to the table of SW102 (5 - 8).
0 line
0
0
0
0
111
1-4
Scan effective image 
area (SPF) back 
surface, Main 
scanning, Left image 
loss
Binary input
Setting range: -56 to +56 dots  1step = 8 dots
For Bit No., refer to the table of SW103 (1 - 4).
(However, the unit of a set value is dots.)
0 dot
0
0
0
0
5-8
Scan effective image 
area (SPF) back 
surface, Main 
scanning, Right edge 
image loss
Binary input
Setting range: -56 to +56 dots  1step = 8 dots
For Bit No., refer to the table of SW103 (1 - 4).
(However, the unit of a set value is dots.)
0 dot
0
0
0
0
112
1-8
Scanning 
magnification ratio 
adjustment SPF, back 
surface (Main 
scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
MX-FX13  FAX SOFT SWITCH  4 - 37
113
1-8
Scanning 
magnification ratio 
adjustment SPF, back 
surface (Sub 
scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
114
1-8
Not used
0
0
0
0
0
0
0
0
115
1-8
Not used
0
0
0
0
0
0
0
0
116
1-8
Not used
0
0
0
0
0
0
0
0
117
1-8
Print magnification 
ratio adjustment 
(Main scanning)
Binary input
Setting range -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
118
1-8
Print magnification 
ratio adjustment (Sub 
scanning)
Binary input
Setting range: -12.7 to +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
119
1-8
Print magnification 
ratio adjustment, back 
surface (Main 
scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
MX-FX13  FAX SOFT SWITCH  4 - 38
120
1-8
Print magnification 
ratio adjustment, back 
surface (Sub 
scanning)
Binary input
Setting range: -12.7% to +12.7%  1step = 0.1%
For Bit No., refer to the table of SW104.
0%
0
0
0
0
0
0
0
0
121
1-8
Not used
0
0
0
0
1
1
0
1
122
1-8
Not used
0
1
0
1
0
1
1
0
123
1
CI extinction 
judgment
Goes extinction 
when one cycle 
is out of 
judgment.
0
2, 3
Filter time when 
detecting CI signal
10ms
0
0
4-8
Not used
0
0
0
1
0
124
1-4
Scanner scanning 
completion speaker 
sound volume (Small)
Binary input
Setting range:  0 to 15  (15: Large  1: Small  0: Mute)
4
0
1
0
0
5-8
Scanner scanning 
completion speaker 
sound volume 
(Medium)
Binary input
Setting range:  0 to 15  (15: Large  1: Small  0: Mute)
8
1
0
0
0
125
1-4
Scanner scanning 
completion speaker 
sound volume (Large)
Binary input
Setting range:  0 to 15  (15: Large  1: Small  0: Mute)
13
1
1
0
1
5-8
Speaker sound 
volume in DTMF send 
(Small)
Binary input
Setting range:  0 to 15  (15: Large  1: Small  0: Mute)
4
0
1
0
0
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
1 Goes extinction only when 
the max. cycle is exceeded.
0 Goes extinction when one 
cycle is out of judgment.
Bit No.
Setting value
2
3
0
0
10ms
0
1
5ms
1
0
15ms
1
1
20ms
Page of 80
Display

Click on the first or last page to see other MX-FX13 service manuals if exist.