TECHNICAL BULLETIN
NOTIFICATION OF REVISED DESCRIPTIONS IN THE
INSTALLATION MANUAL FOR MX-FR11U (DSK)
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-731
1. Model Name:
MX4100N – MX4101N – MX5000N – MX5001N
2. General:
This is to notify about revisions in the installation manual [16] MX-FR11/FR11U.
(Primary reasons)
Correction of errors in descriptions.
Addition of work processes along with the addition of the certified model MX-FR11.
Addition of work processes along with the addition of the certified model MX-FR11.
(Major revisions)
Name of parts provided in the same package, 4) Before change: Installation procedures
After change: Notes (MX-FR11 only)
Name of parts provided in the same package, 6) Certificate label (MX-FR11 only) added.
G. Addition of work process "Specifying settings of data security function."
H. Addition of "Affixing the provided certificate label onto the front of main unit" (MX-FR11
G. Addition of work process "Specifying settings of data security function."
H. Addition of "Affixing the provided certificate label onto the front of main unit" (MX-FR11
only).
Addition of accompanying items and correcting errors on MX-FR10.
3. Description:
Refer to attached document for details of revisions.
〔16〕 MX-FR11/FR11U
1. Unpacking
A. Check the packed items
1) Check that all the items are included in the package
1
2
3
4
5
6
No.
Packed part names
Quantity
1
MFP_PRG1 ROM
1
2
MFP_PRG2 ROM
1
3
Operation manual
1
4
Caution sheet (MX-FR11only)
1
5
USB memory
1
6
Certificate label
(MX-FR11only)
1
2. Installation
<Note before installation>
* To enable the data security function, the product key
* To enable the data security function, the product key
must be acquired (For the method of acquiring the
product key, contact the dealer.)
product key, contact the dealer.)
* Before installing the data security kit, be sure to
perform backup of data stored in the memory
(including HDD) of the main unit. When the data
security kit is installed, all the job data stored in the
memory (including HDD) of the main unit will be lost.
(including HDD) of the main unit. When the data
security kit is installed, all the job data stored in the
memory (including HDD) of the main unit will be lost.
* If the LINE indicator or the DATA indicator for the
printer and image transmission on the operation panel
is lit or blinking, data that has not been processed
remains in the memory of the main unit (including
HDD). Output or transmit all the data to clear the data
remaining in the main unit and then start installation.
(Check to insure that neither the LINE indicator nor the
DATA indicator on the operation panel does light up or
blink.)
is lit or blinking, data that has not been processed
remains in the memory of the main unit (including
HDD). Output or transmit all the data to clear the data
remaining in the main unit and then start installation.
(Check to insure that neither the LINE indicator nor the
DATA indicator on the operation panel does light up or
blink.)
A. Turn off the power switch of the main unit.
1) Turn the power switch located on the operation
panel to the
“OFF” position.
2) After checking that the operation panel has gone
out, open the front cabinet and turn the main power
switch to the
switch to the
“OFF” position.
3) Remove the power plug of the main unit from the
outlet.
B. Pull out the control PWB.
・ If cables are connected to the control PWB unit,
remove all cables.
1) Push the location indicator in the illustration to
unlock, and remove the ozone filter cover from the
right rear cabinet.
right rear cabinet.
2) Remove the screw from the right rear cabinet.
3) Remove the right rear cabinet.
4) Remove the two screws from the control PWB unit.
3) Remove the right rear cabinet.
4) Remove the two screws from the control PWB unit.
・If the fax box unit is installed, carry out steps 5),6)
and 7) additionally.
and 7) additionally.
5) Pull out the control PWB unit and remove the snap
band.
6) Remove the interface cable from the frame.
7) Remove the connector.
8) Pull out and remove the control PWB unit.
7) Remove the connector.
8) Pull out and remove the control PWB unit.
1/4
Common Criteria
Validated
MFP Data Security Kit
Validated
MFP Data Security Kit
C. Mount the data security kit ROMs to the control
PWB unit.
PWB unit.
Remove the ROMs PROG1/PROG2)from the control
PWB and replace them with data security kit ROMs
(MFP_PRG1 /MFP_PRG2)
When mounting the data security kit ROMs, insert
them to the same positions in the same orientations
as those before replacement until they click and
ensure that the inserted ROMs are locked with the
sockets.
as those before replacement until they click and
ensure that the inserted ROMs are locked with the
sockets.
D. Reattach the control PWB and the right rear
cabinet.
cabinet.
・ If the fax box unit is installed, carry out steps 1),2)
and 3) additionally.
1) Connect the interface cable to the control PWB unit.
2) Push the interface cable into the recessed portion of
2) Push the interface cable into the recessed portion of
the sheet metal on the control PWB unit.
3) Attach the snap band to the sheet metal of the
control PWB unit.
4) Push the control PWB unit into the main unit.
5) Secure the unit with the two screws.
5) Secure the unit with the two screws.
・If the fax box unit is installed, carry out step 6)
additionally.
additionally.
6) Fit the interface cable into the right rear cabinet
cover.
7) Attach the right rear cabinet cover to the main unit.
At this time, check that the four hooks are properly
fitted to the main unit.
fitted to the main unit.
8) Secure the right rear cabinet with the screw
9) Attach the ozone filter cover to the main unit.
・ Reconnect the cables that have been removed in
step B to the original positions of the control PWB
unit.
unit.
E. Turn on the main power switch of the main unit.
1) Insert the power plug of the main unit to the outlet.
2/4
2) Turn on the main power switch
3) Turn on the power switch located on the operation
panel.
F. Installation of the DSK firmware
(1) MFP booting operations after replacement
1) Turn ON the power, and the main program error is
displayed
Main Program Error!!
2) After 10 seconds from displaying the above error, the
following display is made.
Emergency Prog Init
Please wait
Please wait
3) The main program version is displayed, and the
machine enters the boot mode.
Version Check
conf: xxxxxxxx
conf: xxxxxxxx
(2) Boot Mode operation
Install the DSK firmware as follows.
a. Operations and functions of the keys in the boot mode
Normal key name
Boot mode key
name
Function
Start key
(monochrome)
(monochrome)
[OK] key
Executes the selected
function or item
function or item
Home key
[MENU] key
Selects a menu
Job Status key
[UP] key
Selects an item
System setting key
[DOWN] key
Selects an item
b. Function selection in the Boot Mode
The functions of the boot mode can be selected by
pressing MENU key as shown in the figure below.
pressing MENU key as shown in the figure below.
Version Check
conf: xxxxxxxx
conf: xxxxxxxx
MENU key
MENU key
Firm Update
From USB Memory
From USB Memory
(3) DSK Firmware installing procedures in the boot mode
1) Boot the machine in the boot mode. With
“Version
Check
” displayed. Press [MENU] key. and the machine
enters the firmware update mode. (
“Firm Update” is
displayed)
Firm Update
From USB Memory
From USB Memory
2) Insert the USB memory with the installation or update
firmware file (SFU file) in it into the USB port of the
machine, and press [OK] key
machine, and press [OK] key
Firm Update
> xxxxxxxx.sfu
> xxxxxxxx.sfu
3) Select the target firmware file SFU file)by using
[UP] key and [DOWN] key
・When [OK] key is pressed with the directory name
displayed, the control can enter the lower level
directory (However, one level lower only)
・When [OK] key is pressed with the directory name
displayed, the control can enter the lower level
directory (However, one level lower only)
4) Press [OK] key.
The selected firmware file SFU file) is read. (It takes
about one minutes)
about one minutes)
Firm Update
Reading Data
Reading Data
3/4
Display