MX-FNX1/MX-PNX1  SELF DIAGNOSTICS AND TROUBLE CODES  9 – 1
âºíuÇ´
Service Manual
 
[9] SELF DIAGNOSTICS AND 
TROUBLE CODES
1. Trouble code and troubleshooting
A. MX-FNX1
Phenomenon
Though the main switch of the main unit is turned ON, the 
inner finisher does not operate. Trouble code: F1-00
Case 1
Cause
Connection failure with the main unit. 
Check & 
Remedy
Check to confirm the connection state of the 
connectors. 
Case 2
Cause
Connection failure of the connector contact pin 
(interface harness) with the main unit. 
Check & 
Remedy
Check to confirm the conduction state of the 
connectors. If there is no conduction, replace 
the connection wire. 
Case 3
Cause
Front cover switch (FDSW) trouble
Check & 
Remedy
Check to confirm the conduction state of the 
connectors. If there is no conduction, replace 
the connection wire.
Case 4
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 3, if DC24V and 
DV5V are not supplied from the main unit and 
if 24V is not supplied to TP14 and 5V is not 
supplied to TP17, replace the control PWB. 
Phenomenon
The transport motor (FRM) does not operate. 
The bundle exit motor (FAM) does not operate. 
Case 1
Cause
Motor connector pin contact failure
Check & 
Remedy
Check the connection state of the connector. 
(CN14)
Case 2
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the motor.
Case 3
Cause
Control PWB trouble
Check & 
Remedy
If the motor does not operate in the motor 
single operation mode, replace the control 
PWB. 
Phenomenon
Roller up/down motor (FSWM) does not operate. Trouble 
code: F1-03
Case 1
Cause
Roller up/down sensor (FRLD) trouble
Check & 
Remedy
Measure the voltage of TP12 on the control 
PWB to confirm that it is 5V
±5% when the 
paper exit roller descends, and 1V or less 
when the paper exit roller rises. If the voltage 
does not satisfy the said condition, replace the 
sensor. 
Case 2
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the motor.
Case 3
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 and 2, if the 
phenomenon is not removed though the 
sensor level is changed and if the motor does 
not operate in the motor single operation 
mode, replace the control PWB.
Phenomenon
The alignment motor F (FFJM) does not operate. 
Trouble code: F1-19
The alignment motor R (FRJM) does not operate. 
Trouble code: F1-20
Case 1
Cause
Alignment plate HP sensor F (FFJHPD) 
trouble
Check & 
Remedy
Measure the voltage of TP9 on the control 
PWB to confirm that it is 5V
±5% when the 
alignment plate is pushing against the center 
portion, and is 1V or less when the alignment 
plate is pushing against the front side (home 
position). If the voltage does not satisfy the 
above condition, replace the sensor. 
Case 2
Cause
Alignment plate HP sensor R (FRJHPD) 
trouble
Check & 
Remedy
Measure the voltage of TP10 on the control 
PWB to confirm that it is 5V
±5% when the 
alignment plate is pushing against the center 
portion, and is 1V or less when the alignment 
plate is pushing against the rear side (home 
position). If the voltage does not satisfy the 
above condition, replace the sensor.
Case 3
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the coil. 
Case 4
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 3, if the 
phenomenon is not removed though the 
sensor level is changed and if the motor does 
not operated in the motor single operation 
mode, replace the control PWB. 
Phenomenon
A paper jam error is displayed on the system display. 
Case 1
Cause
Paper jam
Check & 
Remedy
Visually check and remove the paper jam
Case 2
Cause
Inlet port sensor (FED) trouble
Check & 
Remedy
Measure the voltage of TP11 on the control 
PWB to confirm that it is 1V or less when 
paper is empty, and is 5V
±5% when paper is 
provided. If the voltage does not satisfy the 
above condition, replace the sensor.
Case 3
Cause
Empty sensor (FSTPD) trouble
Check & 
Remedy
Measure the voltage of TP8 on the control 
PWB to confirm that it is 1V or less when 
paper is empty, and is 5V
±5% when paper is 
provided. If the voltage does not satisfy the 
above condition, replace the sensor.
Case 4
Cause
Control PWB trouble
Check & 
Remedy
If the phenomenon is not removed though the 
sensor level is changed by turning ON/OFF 
each sensor, replace the control PWB.
Phenomenon
Case 1
Cause
Tray paper empty sensor (FBED) trouble
Check & 
Remedy
Measure the voltage of TP4 on the control 
PWB to confirm that it is 5V
±5% when paper is 
empty, and is 1V or less when paper is 
provided. If the voltage does not satisfy the 
above condition, replace the sensor.
Case 2
Cause
Control PWB trouble
Check & 
Remedy
If the phenomenon is not removed though the 
sensor level is changed by turning ON/OFF 
each sensor, replace the control PWB.
MX-FNX1/MX-PNX1  SELF DIAGNOSTICS AND TROUBLE CODES  9 – 2
Phenomenon
A document is discharged to the reverse path in the 
operation other than reverse operation. 
Case 1
Cause
Flapper solenoid (FINRPS) connector pin 
trouble
Check & 
Remedy
Check the connection state of the connector. 
(CN15)
Case 2
Cause
Solenoid coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the coil. 
Case 3
Cause
Control PWB trouble
Check & 
Remedy
If the flapper solenoid (FINRPS) does not 
operate in the solenoid single operation mode, 
replace the control PWB. 
Phenomenon
The belt separation solenoid (FBRS) does not operate. 
The paper surface detection solenoid (FSLS) does not 
operate
The paddle one-rotation solenoid (FPDS) does not 
operate.
Case 1
Cause
Solenoid connector pin trouble
Check & 
Remedy
Check the connection state of the connector. 
(CN15, 20)
Case 2
Cause
Solenoid coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the coil. 
Case 3
Cause
Control PWB trouble
Check & 
Remedy
If the solenoid does not operate in the single 
operation mode of the belt separation solenoid 
(FBRS), the paper surface detection solenoid 
(FSLS), or the paddle one-rotation solenoid 
(FPDS), replace the control PWB. 
Phenomenon
The take-up belt does not operate normally. 
Case 1
Cause
Take-up belt sensor (FBRD) trouble
Check & 
Remedy
Measure the voltage of TP13 on the control 
PWB to confirm that it is 5V
±5% when the belt 
descends, and is 1V or less when the belt 
separates. If the voltage does not satisfy the 
above condition, replace the sensor.
Case 2
Cause
Control PWB trouble
Check & 
Remedy
If the phenomenon is not removed though the 
sensor level is changed by turning ON/OFF 
each sensor, replace the control PWB.
Phenomenon
The staple shift motor does not operate. 
Trouble code: F1-08 
Case 1
Cause
Stapler HP sensor (FSTHPD) trouble
Check & 
Remedy
Measure the voltage of TP7 on the control 
PWB to confirm that it is 5V
±5% when the 
stapler unit is pushing against the front side 
(home position), and is 1V or less when the 
stapler unit is pushing against the rear side. If 
the voltage does not satisfy the above 
condition, replace the sensor.
Case 2
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the coil. 
Case 3
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 2, if the 
phenomenon is not removed though the 
sensor level is changed and if the motor does 
not operate in the motor single operation 
mode, replace the control PWB. 
Phenomenon
The stapler does not operate. Trouble code: F1-10 
Case 1
Cause
Alignment plate position sensor (FJPD) trouble
Check & 
Remedy
Measure the voltage of TP50 on the control 
PWB to confirm that it is 1V or less when the 
stapler is at the paper rear edge stopper 
section, and is 5V
±5% when the stapler is not 
at that position. If the voltage does not satisfy 
the above condition, replace the sensor.
Case 2
Cause
Stapler home sensor (FSHPD) trouble
Check & 
Remedy
Measure the voltage of TP51 on the control 
PWB to confirm that it is 5V
±5% at the stapling 
mechanism home position, and is 1V or less 
when stapling. If the voltage does not satisfy 
the above condition, replace the stapler.
Case 3
Cause
Self priming sensor (FSTD) trouble
Check & 
Remedy
Measure the voltage of TP52 on the control 
PWB to confirm that it is 5V
±5% when a 
cartridge is provided (READY state), and is 1V 
or less when a cartridge is not provided. If the 
voltage does not satisfy the above condition, 
replace the stapler.
Case 4
Cause
Staple empty sensor (FSD) trouble
Check & 
Remedy
Measure the voltage of TP53 on the control 
PWB to confirm that it is 5V
±5% when a 
cartridge is provided (with staples), and is 1V 
or less when a cartridge is not provided. If the 
voltage does not satisfy the above condition, 
replace the stapler.
Case 5
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the stapler.
Case 6
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 5, if the 
phenomenon is not removed though the 
sensor level is changed and if the motor does 
not operate in the motor single operation 
mode, replace the control PWB. 
Phenomenon
The tray does not operate. Trouble code: F1-15
Case 1
Cause
The paper surface sensor 1 (FSLD1), paper 
surface sensor 2 (FSLD2) trouble
Check & 
Remedy
Measure the voltage of TP5 and 6 on the 
control PWB to confirm that it is changed in the 
range of 1V or less to 5V
±5% when the paper 
holding lever is moved. If the voltage does not 
satisfy the above condition, replace the sensor.
Case 2
Cause
Tray upper limit sensor (FULD) trouble
Check & 
Remedy
Measure the voltage of TP1 on the control 
PWB to confirm that it is 1V or less when the 
tray is at the upper limit position, and is 5V
±5% 
when the tray is not at the upper limit position. 
If the voltage does not satisfy the above 
condition, replace the sensor.
Case 3
Cause
Tray intermediate lower limit sensor (FMLLD) 
trouble
Check & 
Remedy
Measure the voltage of TP2 on the control 
PWB to confirm that it is 1V or less when the 
tray is at the intermediate position, and is 
5V
±5% when the tray is not at the intermediate 
position. If the voltage does not satisfy the 
above condition, replace the sensor.
Case 4
Cause
Tray lower limit sensor (FLLD) trouble
Check & 
Remedy
Measure the voltage of TP3 on the control 
PWB to confirm that it is 1V or less when the 
tray is at the lower limit position, and is 5V
±5% 
when the tray is not at the lower limit position. 
If the voltage does not satisfy the above 
condition, replace the sensor.
Case 5
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there 
is no conduction, replace the stapler.
MX-FNX1/MX-PNX1  SELF DIAGNOSTICS AND TROUBLE CODES  9 – 3
B. MX-PNX1A/B/C/D
Case 6
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 5, if the 
phenomenon is not removed though the 
sensor level is changed and if the motor does 
not operate in the motor single operation 
mode, replace the control PWB. 
Phenomenon
The fan (FFAN) does not operate. Trouble code: F1-
21
Case 1
Cause
Pinching of a foreign material
Check & 
Remedy
Visually check to remove a foreign material from the 
inlet port.
Case 2
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there is no 
conduction, replace the motor.
Case 3
Cause
Lock detection trouble
Check & 
Remedy
Measure the voltage of TP88 on the control PWB to 
confirm that it is 1V or less when lock is released, 
and is 5V
±5% when lock is set. If the voltage does 
not satisfy the above condition, replace it.
Case 4
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 3, if the fan (FFAN) 
does not operate in the motor single operation mode, 
replace the control PWB. 
Phenomenon
Though the main switch of the main unit is turned 
ON, the inner punch does not operate at all.
Case 1
Cause
Connection failure with the inner finisher
Check & 
Remedy
Check to confirm that each connector is connected 
properly.
Case 2
Cause
Connection failure of the drawer connector with the 
inner finisher
Check & 
Remedy
Check the conduction state of the connector pins as 
well as the inner finisher. If there is no conduction, 
replace the drawer connector. 
Case 3
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 and 2, if DC24V and 
DC5V are not supplied from the main unit or if 24V is 
not output to TP19 and 5V is not output to TP22 on 
the control PWB, replace the control PWB. 
Pheno
menon
The punch motor (FPNM) does not operate.
Trouble code: F1-34
Case 1
Cause
Punch position sensor (FPHPD) trouble
Check & 
Remedy
Measure the voltage of TP47 on the inner finisher 
control PWB to confirm that it is 5V
±5% at the home 
position, and is 1V or less when punching. If the 
voltage does not satisfy the above condition, replace 
the sensor.
Case 2
Cause
Rear position sensor (FPRPD) trouble
Check & 
Remedy
Measure the voltage of TP48 on the inner finisher 
control PWB to confirm that it is 5V
±5% at the lower 
limit position, and is 1V or less at the upper limit 
position. If the voltage does not satisfy the above 
condition, replace the sensor.
Case 3
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there is no 
conduction, replace the coil.
Case 4
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 to 3, if the phenomenon 
is not removed though the sensor level is changed 
and if the motor does not operate in the motor single 
operation mode, replace the control PWB.
Phenomenon
Punch horizontal resist motor (FPSM) does not 
operate. Trouble code: F1-33 
Case 1
Cause
Horizontal shift HP sensor (FPSHPD) trouble
Check & 
Remedy
Measure the voltage of TP49 on the inner finisher 
control PWB to confirm that it is 5V
±5% at the home 
position, and is 1V or less at the upper limit position. 
If the voltage does not satisfy the above condition, 
replace the sensor.
Case 2
Cause
Motor coil disconnection
Check & 
Remedy
Perform the conduction test of the coil. If there is no 
conduction, replace the coil.
Case 3
Cause
Control PWB trouble
Check & 
Remedy
After checking the above 1 and 2, if the 
phenomenon is not removed though the sensor level 
is changed and if the motor does not operate in the 
motor single operation mode, replace the control 
PWB.
Phenomenon
The punch dust container full is not detected.
Case 1
Cause
Full sensor (FPDD) trouble
Check & 
Remedy
If there is no punch dust in the punch dust container, 
measure the voltage of TP2 on the control PWB to 
confirm that it is 5V
±5% when the punch dust 
Case 2
Cause
Control PWB trouble
Check & 
Remedy
If the phenomenon is not removed though the 
sensor level is changed by turning ON/OFF the 
sensor, replace the control PWB. 
Phenomenon
Case 1
Cause
Paper jam
Check & 
Remedy
Visually check and remove the paper jam.
Case 2
Cause
Paper rear edge sensor (FPPEND) trouble
Check & 
Remedy
Measure the voltage of TP54 on the inner finisher 
control PWB to confirm that it is 1.05V or less when 
paper is supplied, and is 2.88V or more when paper 
is empty. If the voltage does not satisfy the above 
condition, replace the sensor PWB (LED, PTR).
Case 3
Cause
Paper horizontal resist sensor (FPPD1 to 6) trouble
Check & 
Remedy
Measure the voltage of TP55 on the inner finisher 
control PWB to confirm that it is 1.05V or less when 
paper is supplied, and is 2.88V or more when paper 
is empty. If the voltage does not satisfy the above 
condition, replace the sensor PWB (LED, PTR).
Case 4
Cause
Control PWB trouble
Check & 
Remedy
If the phenomenon is not removed though the 
sensor level is changed by turning ON/OFF the 
sensor, replace the control PWB. 
Display

Sharp MX-FNX1 (serv.man11) Service Manual ▷ Download

  • DOWNLOAD Sharp MX-FNX1 (serv.man11) Service Manual ↓ Size: 117.13 KB | Pages: 3 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp MX-FNX1 (serv.man11) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-FNX1 (serv.man11) Copying Equipment. Information contained in Sharp MX-FNX1 (serv.man11) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.