TECHNICALDESCRIPTIONS>SaddleStitcherSection
TECHNICALDESCRIPTIONS>SaddleStitcherSection
3) Thepaperfoldingrollerrotatesinthearrowdirection,andthepaperpushplateshifts
inthearrowdirection.Thenfoldingofthepaperbundleisstarted.Afterthat,thepaper
pushplatereturnstotheoriginalpositionandstopsthere.
pushplatereturnstotheoriginalpositionandstopsthere.
Paper folding
roller
Paper
bundle
Paper push plate
F-2-49
F-2-49
2
2
2-27
2-27
TECHNICALDESCRIPTIONS>ControllerSection
TECHNICALDESCRIPTIONS>ControllerSection
ControllerSection
Outline
The controller section performs the overall control of the whole machine, and controls the
loadsection,thetransportsection,theprocesstraysection,andthesaddlestitchersection.
loadsection,thetransportsection,theprocesstraysection,andthesaddlestitchersection.
Finisher
Controller section
Load section
Transport section
Intermediate process
tray section
tray section
Finisher
controller PWB
controller PWB
Connected
unit
unit
Saddlefinisher
Controller section
Finisher
controller PWB
controller PWB
Saddle stitcher
controller PWB
controller PWB
Connected
unit
unit
Load section
Transport section
Process tray section
Saddle stitcher
section
•
•
F-2-50
F-2-50
FinishercontrollerPWB
ThefinishercontrollerPWBdrivestheloads(motors,solenoids,etc.)andnotifiesinformation
onthesensorandswitchstatustotheconnectedunit.Italsocontrolstheinnerpunchunit,
andthesaddlestitcherunit.
onthesensorandswitchstatustotheconnectedunit.Italsocontrolstheinnerpunchunit,
andthesaddlestitcherunit.
Finisher
Finisher controller PWB
CPU (IC1)
ASIC1 (IC2)
EEPROM
(IC6)
ASIC2 (IC3)
Inner Punch Unit
(Option)
(Option)
Connected
Unit
Unit
Motor
Solenoid
Clutch
Fan
Switch
Sensor
Saddlefinisher
Motor
Solenoid
Clutch
Fan
Finisher controller PWB
Switch
Sensor
CPU(IC1)
ASIC1(IC2)
EEPROM
(IC6)
ASIC2(IC3)
Saddle stitcher
controller PWB
controller PWB
puncher unit
(option)
(option)
Connected
unit
•
•
F-2-52
F-2-52
2
2
2-28
2-28
TECHNICALDESCRIPTIONS>ControllerSection
TECHNICALDESCRIPTIONS>ControllerSection
ThemajorrolesofthemajorIC'susedinthiscircuitaredescribedbelow.
Name
Role
CPU(IC1)
Controlscommunicationbetweenthiscircuitandtheconnected
unit.
ControlsASIC1/ASIC2.
Storesthefirmwarewhichoperatesthemachine.
unit.
ControlsASIC1/ASIC2.
Storesthefirmwarewhichoperatesthemachine.
ASIC1(IC2)
Controlscommunicationwithoptionunits.
Drivesandcontrolstheloads.
Drivesandcontrolstheloads.
ASIC2(IC3)
Drivesandcontrolstheloads.
EEPROM(IC6)
Storesthecountervaluesandtheadjustmentvalues.
T-2-9
T-2-9
SaddlestitchercontrollerPWB
Saddle stitcher
controller PWB
Sensor
CPU(IC1)
Finisher
controller PWB
Inner trimmer (Option)
Motor
Solenoid
ThemajorrolesofthemajorIC'susedinthiscircuitaredescribedbelow.
Name
Role
CPU(IC1)
Controlscommunicationbetweenthiscircuitandthefinisher.
Drivesandcontrolstheloads.
Storesthefirmwarewhichoperatesthemachine.
Drivesandcontrolstheloads.
Storesthefirmwarewhichoperatesthemachine.
F-2-54
F-2-54
T-2-10
T-2-10
2
2
2-29
2-29
TECHNICALDESCRIPTIONS>PowerSource
TECHNICALDESCRIPTIONS>PowerSource
PowerSource
Outline
TheDCpowerforthismachineissuppliedbythepowerunit.
Thefunctionandthepowerdistributionofthepowerunitareasshowninthetablebelow.
Thefunctionandthepowerdistributionofthepowerunitareasshowninthetablebelow.
Name
Function
Powerunit
GeneratestheDCpower(24Vseries).SuppliestheDCpowertothefinisher
controllerPWB.
controllerPWB.
FinisherSafetySwitch1(Frontcoverswitch)(FNSW101)
FinisherSafetySwitch3(Oscillationguideswitch(Front)(Rear))(FNSW102)
FinisherSafetySwitch2(Staplersafetyswitch)(FNSW103)
FinisherTrayProximitySwitch(Uppertray/Middletray)(FNSW110)
FinisherSafetySwitch3(Oscillationguideswitch(Front)(Rear))(FNSW102)
FinisherSafetySwitch2(Staplersafetyswitch)(FNSW103)
FinisherTrayProximitySwitch(Uppertray/Middletray)(FNSW110)
TurnsON/OFFtheDCpowerof24V.
Protectionfunction
Forovercurrentprotectionof24VDCtodrivethemotor,themotordriverisprovidedwhichincludesafuseoranovercurrentprotectionfunction.
Afuseisprovidedalsointhe24VDCinputsectionofeachcontrollerPWB,anditwillmeltdownwhenanovercurrentflows.
The power PWB is provided with the overvoltage/overcurrent protection function which interrupts the output voltage automatically to prevent the power circuit from being damaged when an
overcurrentoranovervoltageisgeneratedduetoashortcircuitoratroubleontheloadside.
Thecircuitisalsoprovidedwithafuse,whichismeltdowntointerruptpowerconductionwhenanovercurrentflowsintheACline.
Afuseisprovidedalsointhe24VDCinputsectionofeachcontrollerPWB,anditwillmeltdownwhenanovercurrentflows.
The power PWB is provided with the overvoltage/overcurrent protection function which interrupts the output voltage automatically to prevent the power circuit from being damaged when an
overcurrentoranovervoltageisgeneratedduetoashortcircuitoratroubleontheloadside.
Thecircuitisalsoprovidedwithafuse,whichismeltdowntointerruptpowerconductionwhenanovercurrentflowsintheACline.