View Sharp MX-FN19 / MX-FN20 / MX-PN12 (serv.man13) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
1/2
Date:
28
th
April 2014
Model:
See below
Ref.:
CCE1304
Colour:
White
Page:
1 of 2
TECHNICAL BULLETIN
ENHANCEMENT TO PREVENT "F1-00" ERROR
CAUSED BY THE CONTACT FAILURE OF A
PAPER SURFACE DETECTION SENSOR
CAUSED BY THE CONTACT FAILURE OF A
PAPER SURFACE DETECTION SENSOR
1. Model Name:
MX-FNX3/FNX4 (Option for MX-5500N/6200N/6201N/7000N/7001N)
MX-FN11
(Option
for
MX-4110N/4111N/4112N/5110N/5111N/5112N,
MX-4100N/4101N/5000N/5001N,
MX-M283N/M363N/M453N/M503N/M363U/M453U/M503U)
MX-FN18 (Option for MX-4110N/4111N/4112/N5110N/5111N/5112)
MX-FN19/FN20 (Option for MX-6540N/7040N)
2. Symptom:
"F1-00" trouble may occur depends on the level of variation in assembly in case a tray is
attached to a Finisher. This trouble may occur even if the tray is placed on home position
because
the
Paper
surface
detection sensor does not function due to the contact failure.
3. Description:
The shape of Cover Tray Upper has been modified as an enhancement to prevent
contact failure between a tray and a paper surface detection sensor.
-
Cover
Tray
Upper
These areas are thickened by
0.5 mm in depth and 5 mm in width.
Sharp Electronics (UK) Ltd., Document Systems Support
2/2
4. Action:
From mid-May 2013 production
5. Parts Action:
Ref.
No.
Model
name
Version P/G No.
Current parts
New parts
Price
rank
Q'ty Parts
name
Effective
time
Inter-
change-
ability
Parts code
Parts code
1
MX-FNX3
MX-FNX4
MX-FNX4
ALL
9-3
10-3
0CW4146L002// 0CW4146L00203
BN
2
COVER TRAY UP
PS
PS
2013/5
Mid
3
9-40
10-38
0CW4146P251B2 0CW4146P251B3
BM
COVER TRAY
UPPER
UPPER
MX-FN11
MX-FN18
MX-FN18
6-3
7-3
7-3
0CW4146L002// 0CW4146L00203
BN
2
COVER TRAY UP
PS
PS
6-40
7-38
7-38
0CW4146P33002
0CW4146P33003
BM
COVER TRAY
UPPER
UPPER
MX-FN19
MX-FN20
MX-FN20
6-3
7-3
7-3
0CW4F502510// 0CW4F50251004
BK
2
TRAY UPPER
LABEL UNIT
LABEL UNIT
6-40
7-38
7-38
0CW4B51052003
0CW4B51052004
BE
GUIDE,TRAY
UPPER,P
UPPER,P
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.