MATERIAL  SAFETY  DATA  SHEET                                
Page:1/5 
Date Revised : Jul . 22. 2013 
Date Issued   : Mar.21, 2013 
MSDS No. F-02311 
 
1.  PRODUCT AND COMPANY IDENTIFICATION  
Product Name 
: 
MX-C30NT-B/MX-C30GT-B/MX-C30FT-B 
                                     MX-C30AT-B/MX-C30CT-B (Black Toner) 
 
Supplier Identification  : Sharp Corporation 
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan 
Local suppliers are listed below.  Please contact the nearest supplier for additional information. 
 
Area 
(Country) 
(Local suppliers) 
North 
America 
U.S.A. 
Sharp Electronics Corporation 
Sharp Plaza, Mahwah, New Jersey 07495-1163 
Telephone number 
  : 800-237-4277 
Emergency telephone number : 800-255-3924 
Canada 
Sharp Electronics of Canada Ltd. 
335 Britannia Road East, Mississauga, Ontario L4Z 1W9 
Telephone number 
  : 905-890-2100 
Emergency telephone number : 1-800-255-3924 
Oceania 
Australia 
Sharp Corporation of Australia PTY. Ltd. 
No1 Huntingwood Drive Huntingwood Blacktown N.S.W. 
Telephone number 
  : 1300-13-50-22 
Europe 
Germany 
Sharp Electronics (Europe) GMBH 
Sonninstrasse 3, 20097 Hamburg 
Telephone number 
  : 040-2376-2185 
United 
Kingdom 
Sharp Electronics (U. K.) Ltd. 
4 Furzeground Way, Stockley Park, Uxbridge Middlesex,  
UB11 1EZ 
Telephone number 
  : 08705-274-277 
France 
Sharp Electronics France S.A. 
 22, Avenue des Nations, Paris Nord 2, BP 52094 / 95948 
 Roissy-Charles de Gaulle, Cedex 
Telephone number 
  : 01-49-90-34-00 
Austria 
Sharp Electronics (Europe) GmbH 
   Handelskai 342 1020 Wien 
Telephone number 
  : 01-727-19-0 
Italy 
Sharp Electronics (Italy) S.P.A. 
   Via Lampedusa, 13 20141 Milano 
Telephone number 
  : 02895951 
Spain 
Sharp Electronics (Espana) S.A. 
  Calle Sena, 2-10 Poligono Industrial Can Sant Joan. Parcela 8, 
 08174 Sant Cugat Del Valles 
Telephone number 
  : 93-581-97-00 
Netherlands 
Sharp Electronics Benelux B.V. 
   P.B. 900 Meidoornkade 10, 3992 AE Houten 
Telephone number 
  : 30-6359500 
Sweden 
Sharp Electronics Nordic AB 
   Box 14098, Gustavslundsvagen 12, SE-167 14, Bromma 
Telephone number 
  : 08-634-36-00 
Switzerland 
Sharp Electronics(Schweiz)AG 
   Moosstrasse 2, Postfach 321 8803 Ruschlikon 
Telephone number 
  : 01-846-6111 
Middle 
East 
U.A.E. 
Sharp Middle East FZE 
P.O.Box 17115 Jebel Ali, Dubai 
Telephone number 
  : 04-8815311 
 
 
 
MATERIAL  SAFETY  DATA  SHEET                                
Page:2/5 
Date Revised : Jul . 22. 2013 
Date Issued   : Mar.21, 2013 
MSDS No. F-02311 
 
2.  COMPOSITION/INFORMATION ON INGREDIENTS 
 
Substance[  ]             Preparation[X] 
 
Ingredient 
CAS No. 
Proportion 
OSHA PEL 
ACGIH TLV 
MAK-TWA 
NOHSC- TWA 
Polyester resin 
Confidential    80-90% 
Not listed 
Not listed 
Not listed 
Not listed 
Carbon black 
1333-86-4 
5-10% 
3.5mg/m
3
 
3.5mg/m
3
 
Not listed 
3mg/m
3
 
Styrene-Acrylate 
copolymer 
Confidential 
1-5% 
Not listed 
Not listed 
Not listed 
Not listed 
Wax 
Confidential 
1-5% 
Not listed 
Not listed 
Not listed 
Not listed 
Iron Oxide 
1309-38-2 
1-5% 
Not listed 
Not listed 
Not listed 
Not listed 
Amorphous silica 
7631-68-9 
1-5% 
80(mg/m
3)
/%SiO
2
 
3mg/m
3
 
Not listed 
Not listed 
 
3.  HAZARDS IDENTIFICATION 
Most Important Hazards and Effects of the Products 
Human Health Effects    : There are no anticipated carcinogenic effects from exposure based on animal tests 
performed using toner.  When used as intended according to instructions, studies do not 
indicate any symptoms of fibrosis will occur. 
Environmental Effects   : Not toxic to aquatic organisms  
Specific hazards 
: Dust explosion (like most finely divided organic powders) 
Directive 1999/45/EC(Europe) 
: Not classified as dangerous 
Australian Information 
: Not classified as hazardous according to criteria of NOHSC. 
 
4.  FIRST-AID MEASURES 
Route(s) of Entry  :  Inhalation? 
 
Skin?   
 
Ingestion? 
 
Yes 
No 
Possible but very unusual. 
  
Inhalation 
: Remove to fresh air.  If symptoms occur, consult medical personnel. 
Skin Contact  : Wash with soap  and water for 15 minutes or until particle is removed.  
If irritation does occur, consult medical personnel.
 
Eye Contact  : flush eyes immediately with water for 15 minutes. If irritation does occur, consult medical personnel. 
Ingestion 
:  Rinse  with  water and  drink several glasses of  water .  If irritation or discomfort does  occur,  consult 
medical personnel. 
 
5.  FIRE-FIGHTING MEASURES
 
Extinguishing Media 
Water,CO
2,
 foam and dry chemicals 
Special Fire fighting Procedures : None 
Fire and Explosion Hazards 
: Toner material, like most finely divided organic powders, may form an explosive 
mixture. 
 
6.  ACCIDENTAL RELEASE MEASURES
 
Personal Precautions 
: None 
Environmental Precautions 
: None 
Methods for Cleaning Up 
: Wipe off with paper or cloth.  Do not use vacuum cleaner when a large amount is 
released.  It, like most finely divided organic powders, is capable of creating a  dust 
explosion. 
 
 
 
MATERIAL  SAFETY  DATA  SHEET                                
Page:3/5 
Date Revised : Jul . 22. 2013 
Date Issued   : Mar.21, 2013 
MSDS No. F-02311 
 
7.  HANDLING AND STORAGE 
Handling 
Technical Measures 
: None 
Precautions 
: None 
Safe Handling Advice  : Use of a dust mask is recommended when handling a large quantity of toner or during long 
term exposure, as with any non-toxic dust. Try not to disperse the particles.   
Storage 
Technical Measures 
: None 
Storage Conditions 
: Keep container closed and Store in a cool and dry place. 
Keep out of the reach of children.  
Incompatible Products     : None 
 
8.  EXPOSURE CONTROLS/PERSONAL PROTECTION 
Engineering Measures   Ventilation : Not required under intended use. 
Exposure limit values  
OSHA-PEL(USA) 
: 15mg/m
3
 (Total Dust) 
, 5mg/m
3
 (Respirable Dust) 
ACGIH-TLV(USA) 
: 10mg/m
3
 (Total Dust) 
, 3mg/m
3
 (Respirable Dust)        
Personal Protective Equipment  
Respiratory Protection 
:  None required when used as intended in Sharp equipment. 
Hand Protection 
:  None required when used as intended in Sharp equipment. 
Eye Protection 
:  None required when used as intended in Sharp equipment. 
Skin Protection 
:  None required when used as intended in Sharp equipment. 
Other Protective Equipment     :  Use of a dust mask and goggles are recommended when handling a large quantity of 
toner or during long term exposure, as with any non-toxic dust. 
 
9.  PHYSICAL AND CHEMICAL PROPERTIES 
Appearance     Physical State : Solid  
Form: Powder                Color: Black 
Odor: odorless 
Ph 
: Not applicable 
Boiling/Melting Point 
: Not applicable 
Softening Point(°C ) 
: 100 - 130 
Flash Point(°C ) 
Not applicable 
Ignition Point(°C ) 
: No data 
Explosion Properties 
: No data  
Density(g/cm³) 
: Approx. 1.1  (bulk density : Approx. 0.4) 
Solubility in water 
  : Negligible 
 
10.  STABILITY AND REACTIVITY 
Stability 
: Stable  
Hazardous Reactions 
: Dust explosion, like most finely divided organic powders. 
Conditions to Avoid 
: Electric discharge, throwing into fire. 
Materials to Avoid 
: Oxidizing Materials 
Hazardous Decomposition Products : CO, CO
2
 and NO
X
 
Further Information 
          : None 
 
 
 
 
 
 
MATERIAL  SAFETY  DATA  SHEET                                
Page:4/5 
Date Revised : Jul . 22. 2013 
Date Issued   : Mar.21, 2013 
MSDS No. F-02311 
 
11.  TOXICOLOGICAL INFORMATION 
Acute Toxicity  
 
Ingestion(oral) 
: LD
50
>2000mg/kg(Rats)   
 
Inhalation 
: LC
50
>5.00mg/l (Rat,4hr)   
 
Eye irritation 
: Not an irritant(Rabbits)   
 
Skin irritation 
: Not an irritant(Rabbits)   
 
Skin sensitizer 
: Not sensitized   
Mutagenicity 
: Negative(Ames Test)  
Carcinogenicity 
:  In  1996  the  IARC  reevaluated  carbon  black  as  a  Group  2B  carcinogen  (possible  human 
carcinogen).    This  classification  is  given  to  chemicals  for  which  there  is  inadequate  human 
evidence, but sufficient animal evidence  on  which to base an opinion of carcinogenicity.  The 
classification is based upon the development of lung tumors in rats receiving chronic inhalation 
exposures  to  free  carbon  black  at  levels  that  induce  particle  overload  of  the  lung.    Studies 
performed in animal models other than rats did not show any association between carbon black 
and  lung  tumors.    Moreover,  a  two-year  cancer  bioassay  using  a  typical  toner  preparation  , 
where  carbon  black  is  bound  in  a  resin  matrix,  demonstrated  no  association  between  toner 
exposure and tumor development in rats. 
Chronic Effect 
:  In a  study  in  rats  of  chronic  inhalation  exposure  to  a  typical  toner,  a  mild  to moderate 
degree  of  lung  fibrosis  was  observed  in  92%  of  the  rats  in  the  high  concentration 
(16mg/m
3
) exposure group, and a minimal to mild degree of fibrosis was noted in22% of 
the  animals  in  the  middle  (4mg/m
3
)  exposure  group,  but  no  pulmonary  change  was 
reported in the lowest (1mg/m
3
) exposure group, the most relevant level to potential human 
exposures. 
  
12.  ECOLOGICAL INFORMATION
 
Ecotoxicity 
On available data, toner is not harmful to aquatic organisms 
  
  
13.  DISPOSAL CONSIDERATIONS 
Waste from residues 
: Waste material may be dumped or incinerated under conditions  which meet all federal, 
state and local environmental regulations. 
Contaminated Packaging : Waste may be disposed or incinerated under conditions which meet all federal, state 
and local environmental regulations. 
  
14.  TRANSPORT INFORMATION 
UN Classification 
: None 
Not classified as hazardous for transport. 
 
 
 
 
 
 
 
 
 
 
Page of 5
Display

Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man83) Regulatory Data ▷ Download

  • DOWNLOAD Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man83) Service Manual ↓ Size: 42.76 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Regulatory Data for the Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man83) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man83) Copying Equipment. Information contained in Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man83) Regulatory Data (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.