Sharp MX-B201D (serv.man8) Service Manual ▷ View online
MX-FX12 FAX SOFT SWITCH 2 - 4
S
W
7
4
Dial tone
monitoring time
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF
detection time
upper limit
(Intermittent
detection)
detection time
upper limit
(Intermittent
detection)
Used to set the upper limit time for detection of dial tone when the
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of
reception
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination
display time when
one-touch key is
pressed
display time when
one-touch key is
pressed
Used to set the time from displaying the destination to the next
operation in one-touch dial or reduction dial.
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory
transmission/
direct transmission
default setup
transmission/
direct transmission
default setup
Used to set whether memory send is ON or direct send is made
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
Memory
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF
detection time
upper limit
(Option)
detection time
upper limit
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online
send.
When set to 1, send in memory mode ON is made in quick online
send.
Yes
1
1: Yes
0: No
5
Remote select
function
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program
“REMOTE RECEPTION
SELECT”.
“REMOTE RECEPTION
SELECT”.
1: Yes
0: No
6
Number of
checking CNG
checking CNG
Used to set the number of times of CNG detection for judgment of
detection.
detection.
3 times
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 5
S
W
12
1
Call time setup in
automatic
transmission
(T0 timer setup)
automatic
transmission
(T0 timer setup)
Used to set call time in automatic send.
45sec.
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Setting is made by binary input of N into “(5sec. x N) + 30sec.” in
the increment of 5sec.
the increment of 5sec.
2
Binary input
0
Bit No.
1
2
3
4
3
Set range
30 to 45sec. (China, Hong Kong)
1
30 to 60sec. (Singapore,
Indonesia, Thailand, India)
Indonesia, Thailand, India)
4
30 to 75sec. (Excluding the avobe)
1
5
Inhibited to use
0
6
CI detection
Used to set the detection frequency of CI signal (call signal).
4 sine wave
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
6
7
7
4 sine wave
0
0
0
3 sine wave
1
0
2 sine wave
0
1
8
Inhibited to use
0
S
W
13
1
Inhibited to use
0
2
0
3
Ringing volume
Used to set the ringing volume when call-in.
Medium
1
Refer to User program
“RINGER VOLUME”.
“RINGER VOLUME”.
Bit No.
3
4
Silent
0
0
4
Small
0
1
0
Medium
1
0
Large
1
1
5
Speaker volume in
DTMF send
DTMF send
Used to set the volume of transmission and DTMF sound from the
speaker when SPEAKER key is pressed.
speaker when SPEAKER key is pressed.
Medium
1
Bit No.
5
6
Not used
0
0
6
Small
0
1
0
Medium
1
0
Large
1
1
7
Inhibited to use
0
8
0
S
W
14
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
15
1
Busy tone
detection time
(Lower limit)
detection time
(Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
250ms
0
1: 350ms
0: 250ms
2
Busy tone
detection time
(Upper limit)
detection time
(Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
1000ms
0
1: 650ms
0: 1000ms
3
Busy tone
detection time
(Lower limit 2)
detection time
(Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
Follows SW15-1. 0
1: 150ms
0: Follows SW15-1.
4
Signal send level
Used to set signal send level from MODEM.
–12dBm
0 When a value outside the
set range is set, the initial
value is set.
value is set.
5
Setting is made in binary input in the increment of 1dBm.
1
6
Binary input
1
7
Bit No.
4
5
6
7
8
0
8
Set range
0 (0dBm) to 26 (–26dBm)
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 6
S
W
16
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
17
1
Inhibited to use
0
2
MH fixed (Except
for SG3)
for SG3)
Used to set whether coding capacity is fixed to MH or not in
communication other than SG3.
communication other than SG3.
No
0
1: Yes
0: No (depending on the other
party’s machine)
party’s machine)
3
ECM MMR mode
(Except for SG3)
(Except for SG3)
Used to set whether MMR coding capacity is allowed or not in
communication other than SG3.
communication other than SG3.
Yes
1
1: Yes
0: No
4
ECM JBIG mode
(Except for SG3)
(Except for SG3)
Used to set whether JBIG coding capacity is allowed or not in
communication other than SG3.
communication other than SG3.
Yes
1
1: Yes
0: No
5
Inhibited to use
0
6
MH fixed (in SG3) Used to set whether coding capacity is fixed to MH or not in SG3
communication.
No
0
1: Yes
0: No (depending on the other
party’s machine)
party’s machine)
7
ECM MMR mode
(in SG3)
(in SG3)
Used to set whether MMR coding capacity is allowed or not in SG3
communication.
communication.
Yes
1
1: Yes
0: No
8
ECM JBIG mode
(in SG3)
(in SG3)
Used to set whether JBIG coding capacity is allowed or not in SG3
communication.
communication.
Yes
1
1: Yes
0: No
S
W
18
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
19
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
Recording table
automatic print
automatic print
Used to set whether communication report is automatically
outputted or not when the number of send/receive items which have
not outputted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items
reaches 50.
outputted or not when the number of send/receive items which have
not outputted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items
reaches 50.
No
0
Refer to User program
“AUTO LISTING”.
“AUTO LISTING”.
1: Yes
0: No
7
Inhibited to use
0
8
0
S
W
20
1
Line sound
monitor range
monitor range
Used to set line sound monitor range when line sound monitor
function is used.
function is used.
OFF
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
1
2
2
OFF
0
0
0
Up to NSF signal send/
receive
receive
0
1
All
1
0
3
Inhibited to use
0
4
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 7
S
W
20
5
Receivable
memory capacity
memory capacity
Used to set the remained memory capacity for allowing call-in.
128Kbyte
0
The machine doesn’t arrive when it decreases more than this
capacity.
capacity.
1: 64Kbyte
0: 128Kbyte
6
Inhibited to use
0
7
0
8
0
S
W
21
1
Interval between
completion of
communication
and the next call
completion of
communication
and the next call
Used to set the interval between completion of communication and
the next call.
the next call.
1sec.
0
2
0
3
Setting is made in binary input.
0
4
Binary input
0
5
Bit No.
1
2
3
4
5
6
7
8
0
6
Set range
0 to 255sec.
0
7
0
8
1
S
W
22
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
23
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
24
1
Inhibited to use
0
2
0
3
Specified number
reception (ANTI
JUNK FAX)
reception (ANTI
JUNK FAX)
Used to set whether the FAX receive rejection function is made
valid or not for registered FAX numbers.
valid or not for registered FAX numbers.
Not set.
0
Refer to Main menu “ANTI
JUNK FAX”.
When a value outside the
set range is set, the initial
value is set.
JUNK FAX”.
When a value outside the
set range is set, the initial
value is set.
4
Bit No.
3
4
0
Not set.
0
0
Receive inhibit
0
1
5
Inhibited to use
0
6
Document output
setup in reception
setup in reception
Used to set the document output procedure; whether all the
received documents are collectively outputted after completion of
reception or every page is outputted when it is received.
received documents are collectively outputted after completion of
reception or every page is outputted when it is received.
Output after
reception of
reception of
every page
0
1: Collective output after
completion of reception
completion of reception
0: Output after reception of
every page
every page
7
Inhibited to use
0
8
Automatic
reduction print
reduction print
Used to set whether automatic reduction print is performed or not
so that a document longer than the fixed size and smaller than the
automatic reduction line number setting is printed on fixed size
paper.
so that a document longer than the fixed size and smaller than the
automatic reduction line number setting is printed on fixed size
paper.
Allow
1
Refer to User program
“AUTO RCV REDUCE”.
“AUTO RCV REDUCE”.
1: Allow
0: Inhibit
S
W
25
1
Minimum non-
divide reduce rate
divide reduce rate
The non-divide minimum reduce rate [%] = 100 - (3 x N)
N: 0 - 15 (Default: 10)
N: 0 - 15 (Default: 10)
70% (N=10)
1
2
0
3
1
4
0
5
Inhibited to use
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark