MX-FX12  FAX SOFT SWITCH  2 - 2
2. Soft switch list
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
1
1
Image quality 
priority selection
Used to select the image quality setting when pressing [Clear All] 
key or during auto clear.
Normal
0
Refer to User program 
“RESO.PRIORITY”.
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
1
2
2
Normal
0
0
0
Fine
0
1
Super fine
1
0
3
Inhibited to use
0
4
Auto/Manual 
default setup
Used to select Auto/Manual reception mode when turning on the 
power.
Automatic 
reception
0
Manual reception can be 
set only when external 
telephone is connected.
1: Manual reception
0: Automatic reception
5
Send request 
protection
Used to set enable/disable of the confidential function (inhibit to 
send to erroneous destinations) in send request communication 
(remote send).
The confidential function is performed by collating the number 
registered in this machine and the number registered in the remote 
machine.
Sender number 
 Send request allow number
Protected
0
Refer to User program 
“SECURITY SELECTION”.
1: Not protected
0: Protected
6
Inhibited to use
0
7
0
8
0
S
W
2
1
Remote selection 
number setup
Used to set the number in binary input for remote switch receive 
from external telephone.
However, “
” in the remote switch number (X) is fixed.
5
0 Refer to User program 
“REMOTE RECEPTION #”.
When a value outside the 
set range is set, the initial 
value is set.
2
0
3
0
4
0
5
Binary input
0
6
Bit  No.
1
2
3
4
5
6
7
8
1
7
Set range
0 to 9
0
8
1
S
W
3
1
Density default 
setup
Used to set the density when pressing [Clear All] key or during auto 
clear.
Medium
0
When a value outside the 
set range is set, the initial 
value is set.
2
Bit  No.
1
2
3
4
5
0
3
Light
1
0
0
0
0
1
4
Medium
0
0
1
0
0
0
5
Dark
0
0
0
0
1
0
6
Inhibited to use
0
7
0
8
0
S
W
4
1
Recall interval in 
communication 
error
Used to set the interval for recall when communication is cut off by 
an error during memory send. (Including no response from the 
remote machine.)
1min
0
Refer to User program 
“RECALL INTERVAL (LINE 
ERROR)”.
When a value outside the 
set range is set, the initial 
value is set.
Setting is made in binary input.
2
When set to 0, resend is mad immediately after completion of 
communication.
0
However, the time interval set by SW21 “Interval between 
completion of communication and the next call” is valid.
3
For the New Zealand models, tough it is set to 0, recall is performed 
in an interval of 1min.
0
Binary input
Bit No.
1
2
3
4
Set range
0 to 15min (Others)
4
4 to 15min (Taiwan)
1
1 to 15min (Singapore, 
Indonesia, Thai, India, 
Vietnam, Malaysia)
0: Recall immediately after 
cutting the line
MX-FX12  FAX SOFT SWITCH  2 - 3
S
W
4
5
Recall interval in 
busy
Used to set the interval for the next call when busy tone is detected 
in communication.
3min
0
Refer to User program 
“RECALL INTERVAL 
(BUSY)”.
When a value outside the 
set range is set, the initial 
value is set.
6
Setting is made in binary input.
0
Binary input
7
Bit  No.
5
6
7
8
1
Set range
1 to 15min
8
4 to 15min (Taiwan)
1
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data 
accumulation wait 
time
Used to set wait time for accumulation of image data before 
sending image data directly.
6sec.
0
Bit No.
3
4
6sec.
0
0
4
5sec.
0
1
0
4sec.
1
0
3sec.
1
1
5
Pause time setup
Used to set pause time when registering dials.
2sec.
0 When a value outside the 
set range is set, the initial 
value is set.
6
Binary input
0
7
Bit  No.
Set range
5
6
7
8
1 to 15sec.
1
8
0
S
W
6
1
ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when 
SW34-1 (V.34 mode function) is ON and send is made other than 
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote 
machine may perform checking, when SW43-1 (V.34 mode 
function) is ON, this function is invalid in reception.
Yes
1
1: Yes
0: No
2
CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
Dial tone ON/OFF 
detection time 
lower limit (Option)
Used to set the minimum required time for detection of dial tone.
This is a setting to enhance SW7-1.
It follows SW7-1. 0
1: SW7-1 x 0.7
0: It follows SW7-1.
6
EOL detection 
timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
13sec.
0
1: 25sec.
0: 13sec.
7
Countermeasure 
for echo in 
reception (CED 
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
500ms
1
1: 500ms
0: 75ms
8
Countermeasure 
for echo in 
transmission (After 
reception of DIS, 
hold time up to 
signal send is set.)
Used to set the interval from DIS receive to DSC signal send.
500ms
0
1: 800ms
0: 500ms
S
W
7
1
Dial tone ON/OFF 
detection time 
lower limit 
(Intermittent 
detection)
Used to set the minimum required time for detection of dial tone 
when the dial tone detection is set to “YES” and the kind of the dial 
tone detection is set to “Continuous.”
100ms
0
1: 300ms
0: 100ms
2
Dial tone detection Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a 
certain time (3.5sec.).
Yes
1
1: Yes
0: No
3
Busy tone 
detection
Used to set YES/NO of busy tone detection when calling out.
Yes
1
1: Yes
0: No
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 4
S
W
7
4
Dial tone 
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF 
detection time 
upper limit 
(Intermittent 
detection)
Used to set the upper limit time for detection of dial tone when the 
dial tone detection is set to “YES” and the kind of the dial tone 
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not 
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of 
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination 
display time when 
one-touch key is 
pressed
Used to set the time from displaying the destination to the next 
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory 
transmission/
direct transmission 
default setup
Used to set whether memory send is ON or direct send is made 
(OFF) in the memory mode when pressing [Clear All] key or auto 
clear.
Memory 
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF 
detection time 
upper limit 
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms 
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online 
send.
Yes
1
1: Yes
0: No
5
Remote select 
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program 
“REMOTE RECEPTION 
SELECT”.
1: Yes
0: No
6
Number of 
checking CNG
Used to set the number of times of CNG detection for judgment of 
detection.
3 times
0
When a value outside the 
set range is set, the initial 
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 5
S
W
12
1
Call time setup in 
automatic 
transmission
(T0 timer setup)
Used to set call time in automatic send.
45sec.
0
When a value outside the 
set range is set, the initial 
value is set.
Setting is made by binary input of N into “(5sec. x N) + 30sec.” in 
the increment of 5sec.
2
Binary input
0
Bit No.
1
2
3
4
3
Set range
30 to 45sec. (China, Hong Kong)
1
30 to 60sec. (Singapore, 
Indonesia, Thailand, India)
4
30 to 75sec. (Excluding the avobe)
1
5
Inhibited to use
0
6
CI detection
Used to set the detection frequency of CI signal (call signal).
4 sine wave
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
6
7
7
4  sine  wave
0
0
0
3 sine wave
1
0
2 sine wave
0
1
8
Inhibited to use
0
S
W
13
1
Inhibited to use
0
2
0
3
Ringing volume
Used to set the ringing volume when call-in.
Medium
1
Refer to User program 
“RINGER VOLUME”.
Bit No.
3
4
Silent
0
0
4
Small
0
1
0
Medium
1
0
Large
1
1
5
Speaker volume in 
DTMF send
Used to set the volume of transmission and DTMF sound from the 
speaker when SPEAKER key is pressed.
Medium
1
Bit No.
5
6
Not used
0
0
6
Small
0
1
0
Medium
1
0
Large
1
1
7
Inhibited to use
0
8
0
S
W
14
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
15
1
Busy tone 
detection time 
(Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
250ms
0
1: 350ms
0: 250ms
2
Busy tone 
detection time 
(Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
1000ms
0
1: 650ms
0: 1000ms
3
Busy tone 
detection time 
(Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
Follows SW15-1. 0
1: 150ms
0: Follows SW15-1.
4
Signal send level
Used to set signal send level from MODEM.
–12dBm
0 When a value outside the 
set range is set, the initial 
value is set.
5
Setting is made in binary input in the increment of 1dBm.
1
6
Binary input
1
7
Bit  No.
4
5
6
7
8
0
8
Set range
0 (0dBm) to 26 (–26dBm)
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56
Display

Click on the first or last page to see other MX-B201D (serv.man8) service manuals if exist.