MX-FX12 FAX SOFT SWITCH 2 - 2
2. Soft switch list
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
1
1
Image quality
priority selection
priority selection
Used to select the image quality setting when pressing [Clear All]
key or during auto clear.
key or during auto clear.
Normal
0
Refer to User program
“RESO.PRIORITY”.
When a value outside the
set range is set, the initial
value is set.
“RESO.PRIORITY”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
1
2
2
Normal
0
0
0
Fine
0
1
Super fine
1
0
3
Inhibited to use
0
4
Auto/Manual
default setup
default setup
Used to select Auto/Manual reception mode when turning on the
power.
power.
Automatic
reception
0
Manual reception can be
set only when external
telephone is connected.
set only when external
telephone is connected.
1: Manual reception
0: Automatic reception
5
Send request
protection
protection
Used to set enable/disable of the confidential function (inhibit to
send to erroneous destinations) in send request communication
(remote send).
The confidential function is performed by collating the number
registered in this machine and the number registered in the remote
machine.
Sender number
send to erroneous destinations) in send request communication
(remote send).
The confidential function is performed by collating the number
registered in this machine and the number registered in the remote
machine.
Sender number
Send request allow number
Protected
0
Refer to User program
“SECURITY SELECTION”.
“SECURITY SELECTION”.
1: Not protected
0: Protected
6
Inhibited to use
0
7
0
8
0
S
W
2
1
Remote selection
number setup
number setup
Used to set the number in binary input for remote switch receive
from external telephone.
However, “
from external telephone.
However, “
” in the remote switch number (X) is fixed.
5
0 Refer to User program
“REMOTE RECEPTION #”.
When a value outside the
set range is set, the initial
value is set.
When a value outside the
set range is set, the initial
value is set.
2
0
3
0
4
0
5
Binary input
0
6
Bit No.
1
2
3
4
5
6
7
8
1
7
Set range
0 to 9
0
8
1
S
W
3
1
Density default
setup
setup
Used to set the density when pressing [Clear All] key or during auto
clear.
clear.
Medium
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
2
Bit No.
1
2
3
4
5
0
3
Light
1
0
0
0
0
1
4
Medium
0
0
1
0
0
0
5
Dark
0
0
0
0
1
0
6
Inhibited to use
0
7
0
8
0
S
W
4
1
Recall interval in
communication
error
communication
error
Used to set the interval for recall when communication is cut off by
an error during memory send. (Including no response from the
remote machine.)
an error during memory send. (Including no response from the
remote machine.)
1min
0
Refer to User program
“RECALL INTERVAL (LINE
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
“RECALL INTERVAL (LINE
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
Setting is made in binary input.
2
When set to 0, resend is mad immediately after completion of
communication.
communication.
0
However, the time interval set by SW21 “Interval between
completion of communication and the next call” is valid.
completion of communication and the next call” is valid.
3
For the New Zealand models, tough it is set to 0, recall is performed
in an interval of 1min.
in an interval of 1min.
0
Binary input
Bit No.
1
2
3
4
Set range
0 to 15min (Others)
4
4 to 15min (Taiwan)
1
1 to 15min (Singapore,
Indonesia, Thai, India,
Vietnam, Malaysia)
Indonesia, Thai, India,
Vietnam, Malaysia)
0: Recall immediately after
cutting the line
cutting the line
MX-FX12 FAX SOFT SWITCH 2 - 3
S
W
4
5
Recall interval in
busy
busy
Used to set the interval for the next call when busy tone is detected
in communication.
in communication.
3min
0
Refer to User program
“RECALL INTERVAL
(BUSY)”.
When a value outside the
set range is set, the initial
value is set.
“RECALL INTERVAL
(BUSY)”.
When a value outside the
set range is set, the initial
value is set.
6
Setting is made in binary input.
0
Binary input
7
Bit No.
5
6
7
8
1
Set range
1 to 15min
8
4 to 15min (Taiwan)
1
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data
accumulation wait
time
accumulation wait
time
Used to set wait time for accumulation of image data before
sending image data directly.
sending image data directly.
6sec.
0
Bit No.
3
4
6sec.
0
0
4
5sec.
0
1
0
4sec.
1
0
3sec.
1
1
5
Pause time setup
Used to set pause time when registering dials.
2sec.
0 When a value outside the
set range is set, the initial
value is set.
value is set.
6
Binary input
0
7
Bit No.
Set range
Set range
5
6
7
8
1 to 15sec.
1
8
0
S
W
6
1
ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode
function) is ON, this function is invalid in reception.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode
function) is ON, this function is invalid in reception.
Yes
1
1: Yes
0: No
2
CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
Dial tone ON/OFF
detection time
lower limit (Option)
detection time
lower limit (Option)
Used to set the minimum required time for detection of dial tone.
This is a setting to enhance SW7-1.
This is a setting to enhance SW7-1.
It follows SW7-1. 0
1: SW7-1 x 0.7
0: It follows SW7-1.
6
EOL detection
timer
timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
13sec.
0
1: 25sec.
0: 13sec.
7
Countermeasure
for echo in
reception (CED
tone send interval)
for echo in
reception (CED
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
500ms
1
1: 500ms
0: 75ms
8
Countermeasure
for echo in
transmission (After
reception of DIS,
hold time up to
signal send is set.)
for echo in
transmission (After
reception of DIS,
hold time up to
signal send is set.)
Used to set the interval from DIS receive to DSC signal send.
500ms
0
1: 800ms
0: 500ms
S
W
7
1
Dial tone ON/OFF
detection time
lower limit
(Intermittent
detection)
detection time
lower limit
(Intermittent
detection)
Used to set the minimum required time for detection of dial tone
when the dial tone detection is set to “YES” and the kind of the dial
tone detection is set to “Continuous.”
when the dial tone detection is set to “YES” and the kind of the dial
tone detection is set to “Continuous.”
100ms
0
1: 300ms
0: 100ms
2
Dial tone detection Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec.).
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec.).
Yes
1
1: Yes
0: No
3
Busy tone
detection
detection
Used to set YES/NO of busy tone detection when calling out.
Yes
1
1: Yes
0: No
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 4
S
W
7
4
Dial tone
monitoring time
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF
detection time
upper limit
(Intermittent
detection)
detection time
upper limit
(Intermittent
detection)
Used to set the upper limit time for detection of dial tone when the
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of
reception
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination
display time when
one-touch key is
pressed
display time when
one-touch key is
pressed
Used to set the time from displaying the destination to the next
operation in one-touch dial or reduction dial.
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory
transmission/
direct transmission
default setup
transmission/
direct transmission
default setup
Used to set whether memory send is ON or direct send is made
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
Memory
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF
detection time
upper limit
(Option)
detection time
upper limit
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online
send.
When set to 1, send in memory mode ON is made in quick online
send.
Yes
1
1: Yes
0: No
5
Remote select
function
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program
“REMOTE RECEPTION
SELECT”.
“REMOTE RECEPTION
SELECT”.
1: Yes
0: No
6
Number of
checking CNG
checking CNG
Used to set the number of times of CNG detection for judgment of
detection.
detection.
3 times
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 5
S
W
12
1
Call time setup in
automatic
transmission
(T0 timer setup)
automatic
transmission
(T0 timer setup)
Used to set call time in automatic send.
45sec.
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Setting is made by binary input of N into “(5sec. x N) + 30sec.” in
the increment of 5sec.
the increment of 5sec.
2
Binary input
0
Bit No.
1
2
3
4
3
Set range
30 to 45sec. (China, Hong Kong)
1
30 to 60sec. (Singapore,
Indonesia, Thailand, India)
Indonesia, Thailand, India)
4
30 to 75sec. (Excluding the avobe)
1
5
Inhibited to use
0
6
CI detection
Used to set the detection frequency of CI signal (call signal).
4 sine wave
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
6
7
7
4 sine wave
0
0
0
3 sine wave
1
0
2 sine wave
0
1
8
Inhibited to use
0
S
W
13
1
Inhibited to use
0
2
0
3
Ringing volume
Used to set the ringing volume when call-in.
Medium
1
Refer to User program
“RINGER VOLUME”.
“RINGER VOLUME”.
Bit No.
3
4
Silent
0
0
4
Small
0
1
0
Medium
1
0
Large
1
1
5
Speaker volume in
DTMF send
DTMF send
Used to set the volume of transmission and DTMF sound from the
speaker when SPEAKER key is pressed.
speaker when SPEAKER key is pressed.
Medium
1
Bit No.
5
6
Not used
0
0
6
Small
0
1
0
Medium
1
0
Large
1
1
7
Inhibited to use
0
8
0
S
W
14
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
15
1
Busy tone
detection time
(Lower limit)
detection time
(Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
250ms
0
1: 350ms
0: 250ms
2
Busy tone
detection time
(Upper limit)
detection time
(Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
1000ms
0
1: 650ms
0: 1000ms
3
Busy tone
detection time
(Lower limit 2)
detection time
(Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
Follows SW15-1. 0
1: 150ms
0: Follows SW15-1.
4
Signal send level
Used to set signal send level from MODEM.
–12dBm
0 When a value outside the
set range is set, the initial
value is set.
value is set.
5
Setting is made in binary input in the increment of 1dBm.
1
6
Binary input
1
7
Bit No.
4
5
6
7
8
0
8
Set range
0 (0dBm) to 26 (–26dBm)
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark