Sharp MX-B201D (serv.man6) Service Manual ▷ View online

MX-FX12  TROUBLE CODES  3 - 1
[3] TROUBLE CODES
1. Communication error codes
A. Error code identification
Communication error xx (xxxx)
(In print out, the communication error display is made. In FAX status
check, “NGxxxxxx” is displayed.
When transmission or reception is not executed normally due to dis-
tur-bance in protocol signals and image signals by the trouble in the
line, the code of 6 digits is displayed on the transmission result
check menu (reception result check menu).
Upper 2 digits of a communication error code: 00 – 58 (error code) is
displayed. (Communication result code)
Lower 4 digits of a communication error code: Error code1, Error
code 2
1) Refer to the communication result code.
2) Refer to error code 1.
3) Refer to error code 2.
(Error code 1 other than V.34 mode is “00”.)
<Communication result code>
When the communication doesn't succeed normally by the cause of
a set mistake of the own machine and the other fax machine, the
cause of the communication error is shown in the result column of
Transaction Report/Activity Report by the following character.
<Communication result codes>
(Note) For error codes 16 – 31, V.34 mode communication.
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
0 – 31
For details of 0 – 
31, refer to the 
communication 
result code.
Depends on the 
communication 
disconnection position.
For 16 or later, V.34 mode 
communication.
Result column of  
Report
Content of communication error
BUSY
The calling side cannot establish connection 
with the remote party.
CANCEL
A communication interruption command is 
made during sending/receiving. The 
interruption key is pressed for interruption of 
input. <Send/Receive/Polling RX/Polling TX>
P.FAIL
Power is failed during sending/receiving. 
<Send/Receive/Polling TX/Polling RX>
MEM. FULL
Memory over during reception. <Receive/
Polling RX>
LENGTH OVER
The receive data length of one page exceeds 
the limit. <Receive/Polling RX>
NO RESPONSE
The FAX signal from the remote party is not 
detected within T1 time. <Send/Polling RX>
OK
Success of communication
RX NO POLL
The called side does not have polling function 
in polling reception. <Polling RX>
The called side has no data to send. <Polling 
RX>
RX POLL FAIL
In polling RX, DCN is received for DTC. 
<Polling RX>
In polling TX, there is no send data. <Polling 
TX>
PASSCODE#E
In poling TX, the allow number is not matched. 
<Polling TX>
In polling TX, the system number is not 
matched. <Polling TX>
MEM.FULL
Memory over in quick online sending <Send>
Error 
code
Final reception signal 
(Transmitting side)
Final reception signal 
(Receiving side)
0
Abnormal signal
Abnormal signal
1
NSF, DIS
NSS, DCS
2
CFR
NSC, DTC
3
FTT
EOP
4
MCF
EOM
5
PIP, PIN
MPS
6
RTN,  RTP
PRI-Q
7
No signal
DCN
8
PPR
PPS-EOP
9
PPS-EOM
10
PPS-MPS, PPS-NULL
11
RNR
RR
12
CTR
CTC
13
ERR
EOR-Q
14
PPS-PRI-Q
15
16
Abnormal signal
Abnormal signal
17
NSF, DIS
NSS, DCS
18
CFR
NSC, DTC
19
FTT
PPS-EOP
20
MCF
PPS-EOM
21
PIP, PIN
PPS-MPS, PPS-NULL
22
RTN, RTP
PRI-Q
23
No signal
DCN
24
PPR
25
RNR
RR
26
CTR
CTC
27
ERR
EOR-Q
28
PPS-PRI-Q
29
V.8 Phase-1
V.8 Phase-1
30
V.8 Phase-2
V.8 Phase-2
31
V.8 Phase-3
V.8 Phase-3
MX-FX12  TROUBLE CODES  3 - 2
<Error codes 1>
Error codes 1 are fixed to “00”.
<Error codes 2>
Error 
codes 2
Content of communication interruption
Transmission/
Reception
01
Transmission length over
Transmission
02
EOL time over
Reception
03
Carrier detection time up
Reception
04
Polarity reversion detection (in phase C) Transmission/
Reception
05
8 min over (in phase C)
Transmission
06
Memory image decoding error
Reception
07
Memory image decoding error
Transmission
08
Time up between frames in phase C
Transmission/
Reception
10
Communication request NG
Reception
11
Polarity reversion detection
Reception
12
Invalid command reception
Reception
13
Time over (1min timer/6sec timer)
Reception
14
PUT error
Reception
15
Time out occurrence during shift from 
Primary to Control in V.34 mode
Reception
20
Polarity reversion detection
Transmission
21
Invalid command reception
Transmission
22
Fall back retry number over
Transmission
23
Resend over of retry number
Transmission
24
Time over (T5 timer)
Transmission
25
Time over (T5 timer) in V.34 mode
Transmission
26
Time out occurrence during shift from 
Primary to Control in V.34 mode
Transmission
30
Communication error due to 
communication abnormality between 
FAX_SUB and FAX_MAIN
Transmission/
Reception
MX-FX12  CIRCUIT DIAGRAM  4 - 1
[4] CIRCUIT DIAGRAM
1. FAX OPERATION
A
A
B
B
C
C
D
D
E
E
4
4
3
3
2
2
1
1
F-KEYI
N6
F-KEYI
N1
F-KEYSC
3
LED_V
3
F-KEYI
N4
F-KEYI
N7
F-KEYI
N2
F-KEYI
N3
DA
T
A
1
LED_V
2
F-KEYSC
2
F-KEYSC
1
F-KEYI
N5
LED_V
1
CONTK
LS
L
MEML
S
FTL
SFTK
OT3K
MEMK
OT6K
OT8K
OT9K
RE
SOK
OT5K
BC
K
S/
SK
OT1K
OT7K
OT4K
CS
KR
/P
K
RMODK
OT2K
REPK
SPKK
2S
IDEK
KEY406
SKQNA
B
D010
KEY406
SKQNA
B
D010
KEY421
SKQNA
B
D010
KEY421
SKQNA
B
D010
KEY416
SKQNA
B
D010
KEY416
SKQNA
B
D010
KEY420
SKQNA
B
D010
KEY420
SKQNA
B
D010
D402
1SS133
D402
1SS133
KEY407
SKQNA
BD010
KEY407
SKQNA
BD010
KEY413
SKQNA
BD010
KEY413
SKQNA
BD010
LT
L-1LHG-002A
LED402
LT
L-1LHG-002A
LED402
D403
1SS133
D403
1SS133
KEY408
SKQNA
B
D010
KEY408
SKQNA
B
D010
CN401
BM15B-GHS-T
B
T
CN401
BM15B-GHS-T
B
T
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
LT
L-1LHG-002A
LED403
LT
L-1LHG-002A
LED403
KEY40
9
SKQNA
BD010
KEY40
9
SKQNA
BD010
LT
L-1LHG-002A
LED401
LT
L-1LHG-002A
LED401
KEY403
SKQNA
BD010
KEY403
SKQNA
BD010
KEY418
SKQNA
B
D010
KEY418
SKQNA
B
D010
KEY415
SKQNA
B
D010
KEY415
SKQNA
B
D010
KEY401
SKQNA
B
D010
KEY401
SKQNA
B
D010
KEY41
9
SKQNA
B
D010
KEY41
9
SKQNA
B
D010
KEY410
SKQNA
BD010
KEY410
SKQNA
BD010
TP
1
TP
1
KEY417
SKQNA
BD010
KEY417
SKQNA
BD010
KEY402
SKQNA
B
D010
KEY402
SKQNA
B
D010
KEY404
SKQNA
B
D010
KEY404
SKQNA
B
D010
KEY412
SKQNA
B
D010
KEY412
SKQNA
B
D010
D401
1SS133
D401
1SS133
KEY405
SKQNA
B
D010
KEY405
SKQNA
B
D010
KEY414
SKQNA
B
D010
KEY414
SKQNA
B
D010
KEY411
SKQNA
B
D010
KEY411
SKQNA
B
D010
FAX
OPERATION
PWB
1/1
 
No part of this publication may be reproduced,
stored in a retrieval system, or transmitted in
any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without
prior written permission of the publisher.
COPYRIGHT
©
XXXX BYSHARP CORPORATION
ALL RIGHTS RESERVED.
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder.
LEAD-FREE SOLDER
The alphabet following the LF mark shows the kind of lead-free solder.
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread.
Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting-point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the
exclusive-use soldering iron is recommended.
(2) NOTE FOR SOLDERING WORK
Since the melting-point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering
capacity is inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land
separation or may exceed the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when
completion of soldering is confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron
tip after completion of soldering work.
If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.
Example:
5mm
Lead-Free
Solder composition
code (Refer to the
table at the right.)
<Solder composition code of lead-free solder>
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
Page of 56
Display