MX-FX12 FAX SOFT SWITCH 2 - 15
S
W
49
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
50
1
Line monitor
volume
volume
Used to set on-hook monitor volume and line volume in FAX
communication.
communication.
Medium
1
When SPEAKER key is
pressed, user setting can
be made.
pressed, user setting can
be made.
Bit No.
1
2
2
Silent
0
0
0
Small
0
1
Medium
1
0
Large
1
1
3
Inhibited to use
0
4
0
5
0
6
0
7
0
8
0
S
W
51
1
DTMF send level
(High group) setup
(High group) setup
Used to set high-group send level in DTMF signal send.
–6dBm
0 When a value outside the
set range is set, the initial
value is set.
value is set.
2
Setting is made in binary input in the increment of 1.0dBm.
0
3
Binary input
1
4
Bit No.
Set range
Set range
1
2
3
4
5
0 (0.0dBm) to
21 (–21.0dBm)
1
5
0
6
CED detection
time
time
Used to set detection time of CED/ANSam signal for judgment of
detection.
detection.
1000ms
0
1: 500ms
0: 1000ms
7
Busy tone
detection cycle
detection cycle
Used to set detection cycle of pulses of busy tone for detection of
busy tone.
busy tone.
2puls
0
Bit No.
7
8
8
2puls
0
0
0
4puls
0
1
6puls
1
0
10puls
1
1
S
W
52
1
Busy tone
detection level
detection level
Used to set the mini. Detection level in busy tone detection.
–43dB
0
Bit No.
1
2
–43dB
0
0
2
–35dB
0
1
0
–33dB
1
0
–30dB
1
1
3
Inhibited to use
0
4
Super G3 disabled
in the last call-out
of recall in case of
an error
in the last call-out
of recall in case of
an error
Used to set whether Super G3 is disabled or not in the last call-out
of recall in case of a send error.
When, however, the number of recall in case of a send error is 0,
this function does not operate.
of recall in case of a send error.
When, however, the number of recall in case of a send error is 0,
this function does not operate.
Super G3
disabled
0
1: Super G3 enabled
0: Super G3 disabled
5
Error process in
RTN reception
RTN reception
Used to set whether RTN reception is judged as an error or not.
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Error
0
1: Not error
0: Error
6
DT detection level Used to set the detection level for Dial tone.
–43dB
0
–43dB
0
0
7
–35dB
0
1
0
–33dB
1
0
–30dB
1
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 16
S
W
52
8
V.34 control
channel
communication
speed
channel
communication
speed
Used to set control channel communication speed in V.34 mode.
If the remote machine does not make 2400bps enable, the speed is
always 1200bps.
If the remote machine does not make 2400bps enable, the speed is
always 1200bps.
1200bps
0
1: 2400bps
0: 1200bps
S
W
53
1
Maximum DTMF
send level
send level
Used to set the max. send level of DTMF signal.
0dBm
0
2
Setting is made in binary input in the increment of 1.0dBm.
0
3
Binary input
0
Bit No.
Set range
Set range
1
2
3
4
0 (0.0dBm) to
15 (–15.0dBm)
4
0
5
DTMF send level
(difference
between high and
low level)
(difference
between high and
low level)
Used to set DTMF signal send level in low group by the difference
from that in high group.
from that in high group.
+2.0dBm
1
6
Setting is made in binary input in the increment of 0.5dBm.
0
Binary input
7
Bit No.
Set range
Set range
5
6
7
8
0 (–2.0dBm) to
15 (+5.5dBm)
0.5dBm unit
When set to 0: Low group = High
group – (–2.0) dBm
When set to 0: Low group = High
group – (–2.0) dBm
0
8
0
S
W
54
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
55
1
CI signal OFF
detection enable
time
detection enable
time
Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI
(call-in signal).
(call-in signal).
1200ms
1
2
1
3
If OFF time continues more than the set value, it is judged as 1
pulse.
pulse.
1
4
1
5
Setting is made in binary input in the increment of 10ms.
0
6
Binary input
0
7
Bit No.
Set range
Set range
1
2
3
4
5
6
7
0 to 1270ms
0
8
Inhibited to use
0
S
W
56
1
CI signal ON
detection enable
time
detection enable
time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI
(call-in signal).
(call-in signal).
155ms
0
2
If ON time continues more than the set value, it is judged as 1
pulse.
pulse.
0
Setting is made in binary input in the increment of 10ms.
3
Binary input
0
Bit No.
Set range
Set range
1
2
3
0 (155ms) to 7 (225ms)
4
Inhibited to use
0
5
DT/BT detection
frequency range
frequency range
Used to set DT/BT detection frequency range.
245Hz–650Hz
1
Bit No.
5
6
Modem fixed (400Hz)
0
0
6
420Hz–680Hz
0
1
1
360Hz–440Hz
1
0
245Hz–650Hz
1
1
7
Inhibited to use
0
8
0
S
W
57
1
Inhibited to use
0
2
0
3
0
4
0
5
1
6
1
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 17
S
W
58
1
Dual wait inhibit
time after CFR
send
time after CFR
send
Used to set dual wait inhibit time after CFR send.
1600ms
1
2
Setting is made in binary input in the increment of 200ms.
0
3
Binary input
0
Bit No.
Set range
Set range
1
2
3
4
0 to 3000ms
4
0
5
FSK signal
settlement time in
double wait
settlement time in
double wait
Used to set FSK signal settlement time in double (dual) wait.
550ms
0
6
Setting is made in binary input in the increment of 50ms.
1
7
Binary input
1
Bit No.
Set range
Set range
5
6
7
8
Settlement time =
50 (ms) x N + 200 (ms)
50 (ms) x N + 200 (ms)
8
1
S
W
59
1
Inhibited to use
0
2
0
3
Reception SED
ON level
ON level
Used to set reception SED ON level.
–48dB
1
Bit No.
3
4
–43dB
0
0
4
–38dB
0
1
1
–33dB
1
0
–48dB
1
1
5
Compromise
Equalizer
Equalizer
Used to set transmission cable amplitude equalizer.
0dB
0
Bit No.
5
6
0dB
0
0
6
4dB
0
1
0
8dB
1
0
12dB
1
1
7
Reception cable
amplitude
equalizer
amplitude
equalizer
Used to set reception cable amplitude equalizer.
0dB
0
Bit No.
7
8
0dB
0
0
8
4dB
0
1
0
8dB
1
0
12dB
1
1
S
W
60
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
61
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
62
1
Inhibited to use
0
2
0
3
0
4
V.8 mode ANSam
signal send time
signal send time
Used to set ANSam/CED signal send time.
4sec.
0
Bit No.
4
5
3sec.
0
0
5
4sec.
0
1
1
5sec.
1
0
6sec.
1
1
6
Inhibited to use
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 18
S
W
63
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
64
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
65
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
66
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
67
1
Make time
(10PPS) setup
(10PPS) setup
Used to set make time in dialing in 10PPS.
40ms
1
2
Setting is made in binary input in the increment of 1ms.
1
3
Binary input
1
Bit No.
Set range
Set range
1
2
3
4
26 to 41ms
4
0
5
Make time
(20PPS) setup
(China & Thailand
only)
(20PPS) setup
(China & Thailand
only)
Used to set make time in dialing in 20PPS.
0
6
Setting is made in binary input in the increment of 1ms.
0
7
Binary input
0
Bit No.
Set range
Set range
5
6
7
8
9 to 24ms
8
0
S
W
68
1
Inhibited to use
0
2
0
3
0
4
0
5
T1 timer setup
Used to set time for connection of the line when the remote
machine does not respond in FAX communication.
machine does not respond in FAX communication.
40sec.
0
6
0
7
The time of ITU-T standard is 35 ± 5sec.
1
Setting is made in binary input in the increment of 5sec.
8
Binary input
0
Bit No.
Set range
Set range
5
6
7
8
30 to 105sec.
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other MX-B201D (serv.man6) service manuals if exist.