Sharp MX-B201D (serv.man6) Service Manual ▷ View online
MX-FX12 FAX SOFT SWITCH 2 - 11
S
W
37
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
38
1
Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
after completion of communication.
Not output
0
Bit No.
1
2
2
Not output
0
0
0
Not output
0
1
Output
1
0
Output only in an error
1
1
3
Protocol monitor
save
save
Used to set whether the protocol monitor of the last communication
is saved or not. When set to “Saved,” the previous protocol monitor
can be printed with SIM66-21.
is saved or not. When set to “Saved,” the previous protocol monitor
can be printed with SIM66-21.
Yes
1
1: Yes
0: No
4
Inhibited to use
0
5
Flash send time
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
Used to set the Flash send time.
90ms
0
Bit No.
5
6
90ms
0
0
6
180ms
0
1
0
270ms
1
0
360ms
1
1
7
Transfer function
Used to set whether transfer function is enabled or not.
Allow
1
1: Allow
0: Inhibit
8
Inhibited to use
0
S
W
39
1
Threshold of
electric current in
fax starting
electric current in
fax starting
Setting of amount of current of line that machine detects at auto
dialing. When it is fewer than this value, the machine is not sent.
dialing. When it is fewer than this value, the machine is not sent.
>= 12mA
(LVCS:1)
(LVCS:1)
0
2
Bit No.
1
2
3
0
Current is disregarded.
0
0
0
>= 12mA (LVCS:1)
0
0
1
3
>= 15mA (LVCS:2)
0
1
0
1
>= 18mA (LVCS:3)
0
1
1
>= 21mA (LVCS:4)
1
0
0
4
DTMF signal send
time
time
Used to set DTMF signal send time.
110ms
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Setting is made in binary input by the increment of 10ms.
5
Binary input
1
Bit No.
Set range
Set range
4
5
6
7
8
60 to 310ms
(North America)
70 to 310ms
(Except North America)
10ms unit
6
0
7
1
8
1
S
W
40
1
Number of times
of recall in error
of recall in error
Used to set the number of times of recall when a communication
error occurs.
error occurs.
1 times
0 Refer to User program
“RECALL TIMES (LINE
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 1 times
(U.S.A., Australia, New Zealand)
0 to 5 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(Hong Kong, China)
6
0
7
0
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 12
S
W
41
1
Number of times
of recall in busy
of recall in busy
Used to set the number of times of recall when busy tone is
detected during transmission.
detected during transmission.
2 times
0 Refer to User program
“RECALL TIMES (BUSY)”.
When a value outside the
set range is set, the initial
value is set.
When a value outside the
set range is set, the initial
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 14times
(U.S.A.)
0 to 10 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(China, Hong Kong)
6
0
7
1
8
0
S
W
42
1
Direct send recall
(U.S.A., Canada)
(U.S.A., Canada)
Used to set whether direct send recall wait is allowed or not.
Allow
0
1: Inhibit
0: Allow
2
FAX receive auto
select by CNG
detection
select by CNG
detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
CNG signal is detected with external telephone used.
Allow
1
Refer to User program
“FAX SIGNAL AUTO
RECEIVE”.
“FAX SIGNAL AUTO
RECEIVE”.
1: Allow
0: Inhibit
3
Auto receive
select in
answering
telephone
connection mode
select in
answering
telephone
connection mode
Used to set whether auto receive select function in answering
telephone connection mode is enabled or not.
telephone connection mode is enabled or not.
OFF
0
Refer to Main menu “AM
MODE”.
MODE”.
1: ON
0: OFF
4
Inhibited to use
0
5
0
6
0
7
0
8
0
S
W
43
1
V.34 mode
function
function
Used to set whether V.34 mode is enabled or not as a capacity of
own machine in send/receive.
own machine in send/receive.
ON
1
1: ON
0: OFF
2
Inhibited to use
0
3
0
4
V.34 receive
symbol speed
mask
symbol speed
mask
Used to set symbol speed mask in V.34 receive.
3429
1
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
4
5
6
5
2400
0
0
0
0
2743
0
0
1
2800
0
1
0
6
3000
0
1
1
1
3200
1
0
0
3429
1
0
1
7
Inhibited to use
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 13
S
W
44
1
Sending speed
Used to set the speed of fax sending.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B1-4 is less than 6 (not V.34)
---> operate it at speed set in SW44, B1-4.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B1-4 is over than 7 (V.34)
---> operate it at speed set in SW44, B1-4=5.
V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B1-4 is less than 6 (not V.34)
---> operate it at speed set in SW44, B1-4=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B1-4 is over than 7 (V.34)
---> operate it at speed set in SW44, B1-4
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B1-4 is less than 6 (not V.34)
---> operate it at speed set in SW44, B1-4.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B1-4 is over than 7 (V.34)
---> operate it at speed set in SW44, B1-4=5.
V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B1-4 is less than 6 (not V.34)
---> operate it at speed set in SW44, B1-4=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B1-4 is over than 7 (V.34)
---> operate it at speed set in SW44, B1-4
33.6 K bps ->
V.34
1
2
1
3
1
4
0
Bit No.
1
2
3
4
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12 K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
5
Reception speed
Used to set the speed of fax receiving.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B5-8 is less than 6 (not V.34)
---> operate it at speed set in SW44, B5-8.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B5-8 is over than 7 (V.34)
---> operate it at speed set in SW44, B5-8=5.
V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
and if SW44,B5-8 is less than 6 (not V.34)
---> operate it at speed set in SW44, B5-8=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B5-8 is over than 7 (V.34)
---> operate it at speed set in SW44, B5-8
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B5-8 is less than 6 (not V.34)
---> operate it at speed set in SW44, B5-8.
* If SW43, B1 is off (V.34 mode is off)
and if SW44, B5-8 is over than 7 (V.34)
---> operate it at speed set in SW44, B5-8=5.
V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
and if SW44,B5-8 is less than 6 (not V.34)
---> operate it at speed set in SW44, B5-8=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
and if SW44, B5-8 is over than 7 (V.34)
---> operate it at speed set in SW44, B5-8
33.6 K bps ->
V.34
1
6
1
7
1
8
0
Bit No.
5
6
7
8
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12 K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 14
S
W
45
1
Inhibited to use
0
2
0
3
1
4
0
5
0
6
0
7
0
8
0
S
W
46
1
Inhibited to use
0
2
Specification of
rotating direction
duplex back
surface print
rotating direction
duplex back
surface print
Used to set whether the back surface is rotated 180 degrees in
duplex print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
duplex print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
180 degrees
rotation
1
1: 180 degrees rotation
0: No 180 degrees rotation
3
Priority in the day
of week
of week
Used to set which is indicated first, day or day of week, when date
format is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is
indicated.
When set to 0, day is indicated first, and then day of week is
indicated.
format is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is
indicated.
When set to 0, day is indicated first, and then day of week is
indicated.
No
0
1: Yes
0: No
4
Inhibited to use
0
5
Summer time
Used to set whether summer time function is enabled or not.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
Inhibit
0
Refer to Entry Mode “DAY
LIGHT SAVING”.
LIGHT SAVING”.
1: Allow
0: Inhibit
6
PBX setting
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, Australia,
New Zealand:
Inhibited to use)
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, Australia,
New Zealand:
Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external
line connection method when connected to PBX.
line connection method when connected to PBX.
Setting OFF
0
Refer to User program
“PBX SETTING MODE”.
When a value outside the
set range is set, the initial
value is set.
“PBX SETTING MODE”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
6
7
8
7
Setting OFF
0
0
0
0
Flash send
1
0
1
8
ID send
1
1
0
0
S
W
47
1
Inhibited to use
0
2
External
telephone
connection
telephone
connection
Used to set whether external telephone is used or not.
This switch must be set to YES in order to use external telephone.
This switch must be set to YES in order to use external telephone.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
0
6
0
7
0
8
0
S
W
48
1
Tone/Pulse default
setup
setup
Used to set the dial type.
TONE
1
Refer to User program
“DIAL MODE”.
When a value outside the
set range is set, the initial
value is set.
“DIAL MODE”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
1
2
2
10PPS
0
0
0
TONE
1
0
3
Telephone line
menu
menu
Used to set whether tone/pulse setting is displayed on the menu or
not.
not.
Allow
0
1: Inhibit
0: Allow
4
Inhibited to use
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark