Sharp MX-B201D (serv.man6) Service Manual ▷ View online

MX-FX12  FAX SOFT SWITCH  2 - 10
S
W
33
1
Page number print 
setup
Used to set whether the page number is added to the sender 
information print or not.
Yes
1
1: Yes
0: No
2
Inhibited to use
0
3
0
4
0
5
0
6
0
7
0
8
Reception data 
duplex print
Used to set whether duplex print of received data is made or not.
No
0
Refer to User program 
“DUPLEX RCV”.
1: Yes
0: No
S
W
34
1
Flash send wait 
time (U.S.A., 
Canada, U.K., 
Netherlands, 
Luxembourg, 
Belgium, France, 
Australia, New 
Zealand: Inhibited 
to use)
Used to set the time from off-hook to Flash send.
1sec.
0
Bit No.
1
2
0sec.
0
0
0.5sec.
0
1
2
1sec.
1
0
0
2sec.
1
1
3
Inhibited to use
0
4
0
5
Signal send level 
Max.
Used to set the max. signal send level.
Binary input
–8dBm
1
6
0
7
Bit  No.
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0
8
0
S
W
35
1
Cover function 
default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine 
returns to this setting.
No
0
1: Yes
0: No
2
Answering 
machine 
connection
Setting to make them connect telephone that has answering 
machine function as external telephone, and unite answering 
machine function to fax receiver function. 
When an absent function of an external telephone is used, it sets it 
to “ON”. 
The setting simultaneously with the dial-in function is improper.
ON
1
1: ON
0: Off
3
CI delete max. 
OFF time
Used to set the max. wait time between detection of CI signal
pulse (number of times) and detection of the next CI signal
pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
5sec.
0
4
Bit  No.
3
4
0
5sec.
0
0
10sec.
0
1
15sec.
1
0
20sec.
1
1
5
Answering 
machine call 
number setting
Used to set the number of calls to switch to auto receive when 
answering telephone is not called in when the receive mode is set 
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
5 times
0
6
1
7
0
Bit No.
Set range
5
6
7
8
0 to 15 times
8
1
S
W
36
1
CNG detection 
completion time
Used to set the time for completion of CNG signal/mute detection in 
the answering telephone connection mode.
Count is made from the last call signal.
45sec.
0 When a value outside the 
set range is set, the initial 
value is set.
2
0
3
1
4
Setting is made in binary input.
0
5
Binary input
1
6
Bit  No.
Set range
1
2
3
4
5
6
7
8
1 to 255sec.
1
7
0
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 11
S
W
37
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
38
1
Protocol monitor
Used to set whether communication protocol result is printed or not 
after completion of communication.
Not output
0
Bit No.
1
2
2
Not output
0
0
0
Not output
0
1
Output
1
0
Output only in an error
1
1
3
Protocol monitor 
save
Used to set whether the protocol monitor of the last communication 
is saved or not. When set to “Saved,” the previous protocol monitor 
can be printed with SIM66-21.
Yes
1
1: Yes
0: No
4
Inhibited to use
0
5
Flash send time 
(U.S.A., Canada, 
U.K., Netherlands, 
Luxembourg, 
Belgium, France, 
Australia, New 
Zealand: Inhibited 
to use)
Used to set the Flash send time.
90ms
0
Bit No.
5
6
90ms
0
0
6
180ms
0
1
0
270ms
1
0
360ms
1
1
7
Transfer function
Used to set whether transfer function is enabled or not.
Allow
1
1: Allow
0: Inhibit
8
Inhibited to use
0
S
W
39
1
Threshold of 
electric current in 
fax starting
Setting of amount of current of line that machine detects at auto 
dialing. When it is fewer than this value, the machine is not sent.
>= 12mA 
(LVCS:1)
0
2
Bit  No.
1
2
3
0
Current is disregarded.
0
0
0
>= 12mA (LVCS:1)
0
0
1
3
>= 15mA (LVCS:2)
0
1
0
1
>= 18mA (LVCS:3)
0
1
1
>= 21mA (LVCS:4)
1
0
0
4
DTMF signal send 
time
Used to set DTMF signal send time.
110ms
0
When a value outside the 
set range is set, the initial 
value is set.
Setting is made in binary input by the increment of 10ms.
5
Binary input
1
Bit No.
Set range
4
5
6
7
8
60 to 310ms 
(North America)
70 to 310ms
(Except North America)
10ms unit
6
0
7
1
8
1
S
W
40
1
Number of times 
of recall in error
Used to set the number of times of recall when a communication 
error occurs.
1 times
0 Refer to User program 
“RECALL TIMES (LINE 
ERROR)”.
When a value outside the 
set range is set, the initial 
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 1 times
(U.S.A., Australia, New Zealand)
0 to 5 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(Hong Kong, China)
6
0
7
0
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 12
S
W
41
1
Number of times 
of recall in busy
Used to set the number of times of recall when busy tone is 
detected during transmission.
2 times
0 Refer to User program 
“RECALL TIMES (BUSY)”.
When a value outside the 
set range is set, the initial 
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 14times
(U.S.A.)
0 to 10 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(China, Hong Kong)
6
0
7
1
8
0
S
W
42
1
Direct send recall
(U.S.A., Canada)
Used to set whether direct send recall wait is allowed or not.
Allow
0
1: Inhibit
0: Allow
2
FAX receive auto 
select by CNG 
detection
Used to set whether FAX receive auto select is enabled or not when 
CNG signal is detected with external telephone used.
Allow
1
Refer to User program 
“FAX SIGNAL AUTO 
RECEIVE”.
1: Allow
0: Inhibit
3
Auto receive 
select in 
answering 
telephone 
connection mode
Used to set whether auto receive select function in answering 
telephone connection mode is enabled or not.
OFF
0
Refer to Main menu “AM 
MODE”.
1: ON
0: OFF
4
Inhibited to use
0
5
0
6
0
7
0
8
0
S
W
43
1
V.34 mode 
function
Used to set whether V.34 mode is enabled or not as a capacity of 
own machine in send/receive.
ON
1
1: ON
0: OFF
2
Inhibited to use
0
3
0
4
V.34  receive 
symbol speed 
mask
Used to set symbol speed mask in V.34 receive.
3429
1
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
4
5
6
5
2400
0
0
0
0
2743
0
0
1
2800
0
1
0
6
3000
0
1
1
1
3200
1
0
0
3429
1
0
1
7
Inhibited to use
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 13
S
W
44
1
Sending speed
Used to set the speed of fax sending. 
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4
33.6 K bps -> 
V.34
1
2
1
3
1
4
0
Bit No.
1
2
3
4
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
5
Reception speed
Used to set the speed of fax receiving.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44,B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8
33.6 K bps -> 
V.34
1
6
1
7
1
8
0
Bit No.
5
6
7
8
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56