MX-B200  SIMULATION, TROUBLE CODES  10 - 18
50
01
Lead edge image position
[Function]
Used to adjust the copy image position and the lead edge void amount on copy paper. The
adjustment is made by adjusting the image scan start position at 100% and the print start posi-
tion (resist roller ON timing). When this simulation is executed, the current set value is dis-
played in 2 digits. (Center value: 50)
When [Exposure mode selector] key is pressed, the setting mode and the display are changed.
Enter the adjustment value and press [START] key to save the set value and make a copy.
When the adjustment is made by the main cassette paper feed, the adjustment values of all the
paper feed ports become the same. (When the set value is increased by 1, shift is made by
0.1mm.)
* When printing with the manual paper feed tray, use paper of the letter size.
[Adjustment procedure]
1) Set the print start position (AE lamp ON) (A), the lead edge void amount (TEXT lamp ON)
(B), and the scan start position (PHOTO lamp ON) (C) to 0, and make a copy of a scale at
100%.
2) Measure the image loss (Rmm) of the scale.
Set C = 10 x R (mm). (Example: Set to 40.)
When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50)
3) Measure the distance (Hmm) from the paper lead edge to the image print start position.
Set A = 10 x H (mm). (Example: Set to 50.)
When the value of A is increased by 10, the image lead edge is moved to the paper lead
edge by 1mm. (Default: 50).
4) Set the lead edge void amount to 
B = 50 (2.5mm). (Default: 50)
When the value of B is increased by
10, the void is extended by about
0.1mm. (For 25 or less, however, the
void amount is regarded as 0.)
∗ The SPF adjustment is made by 
adjusting the SPF image scan start 
position after OC adjustment.
[Operation]
The operation is similar to simulation 46-
01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display lamp
Default
Print start position 
(Main cassette paper feed)
AE mode lamp
Main cassette lamp
50
Print start position 
(2nd cassette paper feed)
AE mode lamp
2nd cassette lamp
50
Print start position 
(Manual paper feed)
AE mode lamp
Manual feed lamp
50
Image lead edge void 
amount
TEXT mode lamp
Main cassette lamp
50
Image scan start position
PHOTO mode lamp
Main cassette lamp
50
Image rear edge void 
amount 
(Cassette paper feed)
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
Main cassette lamp
50
Image rear edge void 
t
AE mode lamp
TEXT
d l
50
5mm
10mm
Distance from the paper lead edge 
to the image lead edge, H = 5mm
Image loss, R = 4mm
(Example)
MX-B200  SIMULATION, TROUBLE CODES  10 - 19
50
06
Copy lead edge position 
adjustment (SPF) (Option)
[Function]
Used to adjust the SPF copy lead edge.
When the adjustment value of the document scan position adjustment is increased by 1, the
scan start timing is advanced by 0.1mm.
The print result is shifted to the opposite direction of the scan start position.
The adjustment mode can be changed by pressing [Exposure mode selector] key. 
(Adjustment range: 1 – 99, Default: 50)
∗ When there is no document in the SPF, copy is inhibited.
[Operation]
The operation is similar to simulation 46-01.
10
Center offset adjustment
[Function]
Used to adjust the center offset position of copy images on copy paper and that in scanning
document.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value and press [START] key to save the setting and make a copy. (When
the set value is changed by 1, the center is shifted by 0.1mm.)
When the adjustment value is increased, the center is shifted to right. When decreased, the
center is shifted to left.
The modes can be selected by pressing [Exposure mode selector] key.
When the set value is changed largely, the area outside the shading area may be scanned to
cause black streaks on the edges.
* When printing with the manual paper feed tray, use paper of the letter size.
* In the 2nd print center offset adjustment, print is made forcibly as 1to2/Short Edge from OC
regardless of duplex setting.
[Operation]
The operation is similar to simulation 46-01.
12
Document off-center 
adjustment
[Function]
Used to adjust document scan off-center adjustment.
The adjustment modes can be selected by pressing [Exposure mode selector] key. 
(Adjustment range: 1 – 99, Default: 50)
When the adjustment value is increased, the print result is shifted to left.
[Operation]
The operation is similar to simulation 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display lamp
Default
Front surface document 
scan position adjustment
AE mode lamp
50
Rear edge void adjustment 
(SPF)
PHOTO mode lamp
50
Mode
Display lamp
Default
Print center offset 
(Main cassette paper feed)
AE mode lamp
Main cassette lamp
50
Print center offset 
(2nd cassette paper feed)
AE mode lamp
2nd cassette lamp
50
Print center offset 
(Manual paper feed)
AE mode lamp
Manual paper feed lamp
50
Mode
Display lamp
Default
Platen document scan 
AE mode lamp
50
SPF document front scan
TEXT mode lamp
50
MX-B200  SIMULATION, TROUBLE CODES  10 - 20
51
02
Resist quantity adjustment
[Function]
Used to adjust the contact pressure of the main unit resist roller and the SPF resist roller onto
paper. When this simulation is executed, the current set value is displayed.
The adjustment modes can be selected by pressing [Exposure mode selector] key.
Enter the adjustment value with [ ] [ ] key and press [START] key to save the set value and
make a copy.
[Operation]
The operation is similar to simulation 46-01.
53
08
SPF scan position automatic 
adjustment (Option)
[Function]
Place a A4 paper (white chart) so that it covers the SPF scan glass and the OC glass together,
and close the SPF.
When this simulation is executed, the current adjustment value is displayed as the initial display.
* Default is 50. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm
In case of AUTO, press [START] key, and the mirror unit scans from the home position to the
SPF scan position with the adjustment value displayed. The SPF glass cover edge position is
calculated from the difference between the SPF glass cover edge and the OC side document
glass CCD output level. If the adjustment is normal, the adjusted value is displayed. If abnor-
mal, the JAM LED lights up with the current set value displayed.
During the JAM LED is lighted, when [START] key is pressed again, execution is performed
again.
[Operation]
The operation is similar to simulation 46-01. (In MANUAL)
61
03
Polygon motor check 
(HSYNC output check)
[Function]
When [START] key is pressed, HSYNC is performed and the polygon motor is rotated for 30sec.
At that time, the ZOOM lamp is lighted for 100msec every time when HSYNC is detected.
The sub code display is lighted. (After completion of execution, it blinks.)
63
01
Shading check
[Function]
Used to display the detection level of white plate for shading.
When [START] key is pressed, the mirror base unit moves to the white plate for shading and the
copy lamp is lighted.
When the light quantity is stabilized, revision is made for every second, and the level of one
pixel at the center of CCD which is not corrected is detected and the value is displayed in deci-
mal values on the LED.
Main 
code
Sub 
code
Contents
Details of function/operation
 Mode
Display lamp
Default
Main cassette paper feed
AE mode lamp
Main cassette lamp
50
2nd cassette paper feed
AE mode lamp
2nd cassette lamp
50
Manual paper feed
AE mode lamp
Manual paper feed lamp
50
Mode
Display lamp
Default
SPF scan position auto 
adjustment
AE mode lamp
50
SPF scan position manual 
adjustment
TEXT mode lamp
50
MX-B200  SIMULATION, TROUBLE CODES  10 - 21
63
02
Black level automatic 
correction
[Function]
Used to acquire the black level target value used for the black level adjustment of white balance.
When this simulation is executed, the current correction value is displayed in 3 digits of 12bit
hexadecimal number.
Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the
density 10 (black side) comes on the left side and that the chart is upside down at the center of
the plate left center.
When [START] key is pressed, the mirror base unit scans the chart and calculates the correc-
tion value.
After completion of correction, the corrected value is displayed on the LED/display.
∗ Default: 0
∗ If the value is set to the default, operation is made with 0x60.
∗ Incase of an error, the JAM lamp lights up.
∗ If C key is pressed during canceling, the machine goes into the sub code entry standby mode 
after canceling.
12
Light quantity stabilization 
wait time setting
[Function]
Used to set the wait time before entering the light quantity level stable evaluation process in the
light quantity stable process of white balance. (Note: The light quantity stable level in the previ-
ous light quantity stable state is used as the target. When the light quantity level reaches the
target during the wait time, the set time of this simulation is ignored and the operation enters the
stable evaluation process.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [ ] [ ] key
 
and press [START] key. The entered value is stored 
and the machine goes into the sub code entry standby mode.
Setting range: 0 – 99 (Complying with the light quantity stable wait time of 0 – 99sec.)
Default: 15 (15sec)
[Operation]
The operation is similar to simulation 9-04.
13
Light quantity stabilization 
band setting
[Function]
When the difference between the maximum and the minimum values of the light quantity level
sampled for 3.2sec in the cycle of 100msec in the white balance light quantity stable process is
within the range set with this simulation, it is judged as the light quantity is stable. (Note: The
magnification ratio of the AFE gain setting is automatically reflected on the stable width.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [ ] [ ] key and press [START] key. The entered value is stored
and the machine goes into the sub code entry standby mode.
Setting range: 1 – 99 (Light quantity stable width: Complying with 1 – 99 in 4095 gradations.)
Default: 16
[Operation]
The operation is similar to simulation 9-04.
Main 
code
Sub 
code
Contents
Details of function/operation
Chart back surface
 
10
Page of 123
Display