Sharp MX-6240N / MX-7040N (serv.man143) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-1174
1. Model Name: MX6240N – MX7040N
2. Description: Upgrade of ICUM, ICU1, ICU2 and PCU-ROM
From mid-July 2013 production
ROM
Control No.
ICUM
ICU1
ICU2
PCU
SCU
DSPF
FAX
E-Manual
C00
0300S100 0300S100 0102S100 0202S100 0100S100 0100S100 0101G100 0130S100
* ICU above is the version described in the ROM management label. Check that the actual
version is: ICUM (MAIN): 03.00.S1.00/ICUM (SUB): 03.00.S1.00/LANGUAGE:
01.22.S1.00/UICONTENTS: 03.00.S1.00/PCL (PROFILE): 01.00.S1.00; by Sim22-5.
* ICU1 above is also the version described in the ROM management label. Check that the
actual version is: ICU1 (MAIN): 03.00.S1.00/ICU1 (BOOT): 01.01.S1.0b/ICU1(SUB):
01.00.S1.0c; by SIM22-5.
Item of change: See the attached sheet
version is: ICUM (MAIN): 03.00.S1.00/ICUM (SUB): 03.00.S1.00/LANGUAGE:
01.22.S1.00/UICONTENTS: 03.00.S1.00/PCL (PROFILE): 01.00.S1.00; by Sim22-5.
* ICU1 above is also the version described in the ROM management label. Check that the
actual version is: ICU1 (MAIN): 03.00.S1.00/ICU1 (BOOT): 01.01.S1.0b/ICU1(SUB):
01.00.S1.0c; by SIM22-5.
Item of change: See the attached sheet
ROM Version Combination History Table
No.
ROM
Control
No.
ICUM ICU1 ICU2 PCU
SCU DSPF FAX E-Manual Action T/R No
(4) B01 0200S1 0200S1 0101S1 0201S1 0100S1 0100S1 0101G1 0130S1
2013/4
Mid
CCE-1144
(3) B00 0200S1 0200S1 0101S1 0200S1 0100S1 0100S1 0101G1 0130S1
2012/12
Mid
CCE-1104
(2) A12 0102S1 0101S1 0100S1 0101S1 0100S1 0100S1 0101G1 0130S1 2012/8
CCE-1058
(1) A01 0101S1 0101S1 0100S1 0101S1 0100S1 0100S1 0101G1 0121S1
2012/7
Mid
ROM UPGRADE ..... (5). Ver 03.00.S1
TECHNICAL BULLETIN
Date:
30
th
September 2013
Model:
MX6240N – MX7040N
Ref.:
CCE-1174
Colour:
White
Page:
1 of 4
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-1174
[Description]
No.
Item
Details
1 Specification
Implementation of support for cloud portal
2 Specification
Modification has been made to be able to use Job Build except the switching of Colour/B&W
when using Vender Mode.
when using Vender Mode.
3 Image Send
While reconnecting to the server with support for passive mode after failing to the connection
in active mode, the communication was not allowed for a while depends on the server. In that
case, the data transmission to FTP site was not allowed until the recovery. A Soft SW has
been added as a countermeasure so that the connection in passive mode is allowed in the
first place.
FAX soft SW (in Sim66-1)
SW No. 96 Bit No. 4
0: Connection in active mode (default)
1: Connection in passive mode
in active mode, the communication was not allowed for a while depends on the server. In that
case, the data transmission to FTP site was not allowed until the recovery. A Soft SW has
been added as a countermeasure so that the connection in passive mode is allowed in the
first place.
FAX soft SW (in Sim66-1)
SW No. 96 Bit No. 4
0: Connection in active mode (default)
1: Connection in passive mode
4 Image Send
NULL was contained after EOI of JPEG file created with the scanning function on our MFP.
As the countermeasure, the modification is made to send the data with cutting the
unnecessary data which is added to the termination or after that when sending JPEG format.
As the countermeasure, the modification is made to send the data with cutting the
unnecessary data which is added to the termination or after that when sending JPEG format.
5 Image Send
Scanning speed when selecting Job Build at the time of Image Send has been improved.
6 Image Send
Modification of machine lockup which occurred after reboot in case the power delivery
discontinued while receiving data using more than one line
discontinued while receiving data using more than one line
7 Image Send
Modification of failure to output received Internet Fax data from particular models
8 Image Send
The Inbound Routing List with the different registration information was output. This problem
has been corrected.
has been corrected.
9 Image Send
Modification of failure to transmit the data in proper size. The data transmitted were slightly
smaller than actual size if Inch size paper was scanned.
smaller than actual size if Inch size paper was scanned.
10 Printer
Modification of a failure to print custom size data in duplex in case the data were output in
Document Filing.
Document Filing.
11 Printer
Modification of garbled characters while printing particular PDF file.
12 Printer
Modification of failure to print out the PS data in case [Network Settings] -> [Print Port
Settings] -> [Use Banner] on LPD tag on web page was enabled.
Settings] -> [Use Banner] on LPD tag on web page was enabled.
13 Printer
Modification of the problems with output of the PS data such as taking too long to print out
large volume data and disappearance of spooled data.
large volume data and disappearance of spooled data.
14 Printer
Modification of machine lockup while printing PS data with many pages
15 Printer
Modification of an error printing particular file from Mac OS
16 Printer
Modification of print in solid black around logo mark in case the data were printed from the
system called AddVantage.
system called AddVantage.
17 Printer
Modification of machine lockup. If particular Corel Draw 11 file was printed via PCL 6 driver,
the machine locked up and was unable to print.
the machine locked up and was unable to print.
18 Printer
Modification of output of improper number of copies in case "Separator page (sysprint.sep)" is
set.
set.
19 Printer
Modification of the failure to print out from SAP
20
Network
communication
communication
Modified to perform a security check input limit item type the following security key every.
When type = WPA security
- Can be registered as a string: 5 digits / 13 digits
- Can be registered only Hex: 10 digits / 26 digits
- No registration other than the above
When type = WPA security
- Can be registered as a string: 8-digit to 63-digit
- Can be registered only Hex: 64 digits
- No other registration
When type = WPA security
- Can be registered as a string: 5 digits / 13 digits
- Can be registered only Hex: 10 digits / 26 digits
- No registration other than the above
When type = WPA security
- Can be registered as a string: 8-digit to 63-digit
- Can be registered only Hex: 64 digits
- No other registration
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-1174
No.
Item
Details
21
Network
communication
communication
If the response to the enquiry from Mac is more than the certain size, in some cases,
EtherTalk communication stopped due to an imperfection of the internal data transferring
processing. This problem has been corrected.
EtherTalk communication stopped due to an imperfection of the internal data transferring
processing. This problem has been corrected.
22
Network
communication
communication
When printing with specifying "Select File from Network Folder to Print" from Document
Filling, in some cases, the data would not be printed out. This problem has been corrected.
Filling, in some cases, the data would not be printed out. This problem has been corrected.
23
Network
communication
communication
When collecting syslog, in some cases, the download of syslog did not complete, and then
the data could be collected. This problem is corrected.
the data could be collected. This problem is corrected.
24
Network
communication
communication
File on NAS could not occasionally be overwritten on SMB server (SMB) feature. This
problem has been corrected.
problem has been corrected.
25
Network
communication
communication
Network communication failed in the certain router (sonicwall tz170) environment. This
problem has been corrected.
problem has been corrected.
26 UI
Modification of failure to display Preview. The problem occurred after machine kept working
for 25 days without turning off (or 1W power-save mode).
for 25 days without turning off (or 1W power-save mode).
27 UI
Modification of failure to delete Document Filing data in a batch
28 UI
On the file list screen of Document Filing, the direction of ▼▲ marks showing the sorting
order was opposite to the direction which was generally used like PC etc. This has been
corrected.
order was opposite to the direction which was generally used like PC etc. This has been
corrected.
29 UI
When Document Filing print was prohibited, [Print Now] key in Document Filing was grayed
out. This problem has been corrected.
out. This problem has been corrected.
30 UI
When reprinting Document Filling data with Offset enabled, in some cases, Offset would be
turned OFF. This problem has been corrected.
turned OFF. This problem has been corrected.
31 UI
If IC card was used for login while external authentication for OSA is enabled, the home
screen indicated no authentication. This problem has been corrected.
screen indicated no authentication. This problem has been corrected.
32 UI
The warning message "Operation is disabled. Please see your administrator for your
assistance." or " This operation is disabled. " was occasionally displayed if IC card
authentication was enabled. This problem has been corrected.
assistance." or " This operation is disabled. " was occasionally displayed if IC card
authentication was enabled. This problem has been corrected.
33 UI
Modification of lock up with the message "Please wait" at the time of log-in to MFP. The
problem occurred when the MFP was set to Device account mode and Document Filing was
set as default screen.
problem occurred when the MFP was set to Device account mode and Document Filing was
set as default screen.
34 UI
It was not possible to force the switching of paper tray while MFP was connected to vending
machine using parallel cable. This problem has been corrected.
machine using parallel cable. This problem has been corrected.
35 Specification
Modification of machine lockup which occurred at the time of startup displaying "Please wait."
36 Specification
Modification of F6-00. The symptoms listed below appeared after switch on a machine or
while recovering from 1W power-save mode:
- Fax job is prohibited, even though other jobs are allowed.
- F6-00 error is displayed on any screen other than Home screen.
- Display of F6-00 error is cleared by pressing OK key, but it is displayed again at the timing of
auto-clear.
while recovering from 1W power-save mode:
- Fax job is prohibited, even though other jobs are allowed.
- F6-00 error is displayed on any screen other than Home screen.
- Display of F6-00 error is cleared by pressing OK key, but it is displayed again at the timing of
auto-clear.
37 Specification
Modification of U2-42 error. The error occurred due to the limitation of the number of file
allowed to open at the same time for Scan to SMB etc.
allowed to open at the same time for Scan to SMB etc.
38 Specification
Change of the time-out timer for read / write HDD from 10 seconds (with 3 retries) to 22
seconds (with 2 retries).
seconds (with 2 retries).
39 Specification
Implementation of modification for E7-03 which occurred if PIO command (standby command)
failed even once.
failed even once.
40 Option
Change of default URL in Web Browse from "http://www.sharp-world.com/" to "about:blank"
(blank page)
(blank page)
41 Process Control
There were some cases where the colour of the output result changed in the process of
continuous printing. This problem has been corrected.
continuous printing. This problem has been corrected.
42 Simulation
Off-set adjustment of SIM did not function when using SRA3 paper. This problem has been
corrected.
corrected.
43 Others
Modification of a failure to transfer Document Filing data to other location in case the data
were backup from old models.
were backup from old models.
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-1174
No.
Item
Details
44 Others
Modification of erasure of Address Book data. It occurred during the auto recovery
process of HDD (remounting procedures after "WatchDogError"). As a countermeasure,
the machine stops for E7-03(09) error instead of the remounting for auto recovery.
process of HDD (remounting procedures after "WatchDogError"). As a countermeasure,
the machine stops for E7-03(09) error instead of the remounting for auto recovery.
45 Others
When "Repeat Layout (Fixed Repeat)" in Copy Special Modes is selected and also
"Original size: A4/A4R, Paper size: A3, Repeat Number: 2" is set up, the auto calculated
magnification becomes 100% and then the image of A4 original can equally be placed
on A3 paper as a result.
* This feature is enabled/disabled in the Soft SW (in Sim55-3_No.30-7). For Taiwan, this
SW is set to 1 (ON) as default and for other destinations, it is set to 0 (OFF) as default.
"Original size: A4/A4R, Paper size: A3, Repeat Number: 2" is set up, the auto calculated
magnification becomes 100% and then the image of A4 original can equally be placed
on A3 paper as a result.
* This feature is enabled/disabled in the Soft SW (in Sim55-3_No.30-7). For Taiwan, this
SW is set to 1 (ON) as default and for other destinations, it is set to 0 (OFF) as default.
Display