MX-7000N  LSU SECTION  i – 7
4)
Remove the screw (D), and remove the LSU thermistor 1 (E).
Disconnect the connector (F).
B. Others
(1) LSU shutter solenoid CL
1)
Remove the left cabinet. (Refer to the “[A] EXTERNAL OUT-
FIT”.)
2)
Remove the LSU. (Refer to the "(1) LSU".)
3)
Disconnect the connector (A), and remove the screw (B), and
remove the LSU shutter solenoid CL unit (C).
* When installing, insert the U-cut part (D) of solenoid arm to
the shaft (E).
4)
Disconnect the connector (F). Remove the screws (G), and
remove the LSU  shutter solenoid CL (H).
* When installing, hook the solenoid pin (I) to the solenoid arm
(J).
(2) LSU shutter solenoid BK
1)
Remove the rear cabinet and rear cabinet lower. (Refer to the
"[A] EXTERNAL OUTFIT".)
Parts
Mainte
nance
Page
a
LSU shutter solenoid CL
i - 7
b
LSU shutter solenoid BK
i - 7
c
Cleaning base
 ▲
i - 9
Parts
a
LSU shutter solenoid CL
D
E
F
1-f
b
a
c
a
Parts
b
LSU shutter solenoid BK
A
B
C
D
E
F
G
G
H
I
J
a
b
MX-7000N  LSU SECTION  i – 8
2)
Remove the screws (A), and open the control box (B).
3)
Remove the screws (C), and remove the flywheel (D).
* Check to confirm that has not come in contact with the har-
ness etc.
4)
Disconnect the connector (E). Remove the screws (F). Disen-
gage the pawl (G), and remove the duct (H).
5)
Disconnect the connector (I). Remove the screws (J), and
remove the LSU shutter solenoid BK uint (K).
* When installing, engage the shutter drive shaft (L) to the
solenoid arm (M).
6)
Disconnect the connector (N), and remove the snap band (O).
Remove the screws (P), and remove the mounting plate (Q).
* When installing, engage the spring (R) to the groove (S) of
the mounting plate and the groove (T) of the solenoid arm.
7)
Disengage the pawl (U), and remove the LSU shutter solenoid
BK (V).
B
B
A
A
C
D
C
G
F
H
E
J
K
L
M
I
N
P
P
Q
R
S
T
O
V
U
b
MX-7000N  LSU SECTION  i – 9
(3) Cleaning base
1)
Open the front cabinet (A).
2)
Remove the cleaning rod (B).
3)
Remove the dirty cleaning base (C).
4)
Open the cover (D), and pull out the cleaning base (E) for
replacement.
5)
Attach the new cleaning base (F) to the mounting hole with fit-
ting to the pawl.
Parts
Mainte
nance
c
Cleaning base
 ▲
c
A
B
C
c
D
E
F
MX-7000N  LSU SECTION  i – 10
4. Maintenance
 : Check  { : Clean  ▲ : Replace  U : Adjust  ✩ : Lubricate  †  : Shift the position
(Clean, replace, or adjust according to necessity.)
No.
Part name
Monochrome 
supply, 
Mechanical 
parts
When 
calling
300
K
600
K
900
K
1200
K
1500
K
1800
K
2100
K
2400
K
2700
K
3000
K
Remark/Refer to 
the Parts Guide. 
Block/Item No. 
(Only the 
replacement 
parts are 
described.)
1
Dust-proof glass
Mechanical 
parts
{
{
{
{
{
{
{
{
{
{
{
2
Cleaning base
(P/G No. : [2]-50)
(P/G No. : [49]-40)
1
2
1
1
1
Page of 10