Sharp MX-5500N / MX-6200N / MX-7000N (serv.man6) Handy Guide ▷ View online
31
22-04-2008
EFi System Software Installation
5. The connection type window should appear – this should be pre-selected to Ethernet.
Click Next.
6. Perform the required steps as displayed within the following Confirmation window:-
32
22-04-2008
EFi System Software Installation
Notes:
a. To set the Fiery Controller to “Service Mode”, set Dip Switches SW1 & SW2 to On, as
a. To set the Fiery Controller to “Service Mode”, set Dip Switches SW1 & SW2 to On, as
shown below:-
b. Ensure a Cross-Over Ethernet cable is connected between the Fiery Controller & PC.
7. Power on the Fiery Controller (FF should be displayed on the Fiery LED display once the
power on self test has been completed).
8. System Software installation will commence once the Fiery Controller has initialised.
Note: If the Windows Firewall has not been disabled, System Software installation may
not start.
9. When prompted, insert CD2. Click OK.
33
22-04-2008
EFi System Software Installation
10. After installation is complete, perform the required steps as displayed:-
Note: Ensure the Fiery Print Controller has been powered off, both SW1 & SW2 DIP
switches returned to “Normal” mode (OFF) and all cables (Ethernet and Video I/F)
have been re-connected.
have been re-connected.
11. Click Next & Finish.
System Software Installation is complete.
34
22-04-2008
Firmware & Print Driver Revision
Engine Firmware
MX5500N, MX7000N
ICU (Main)
ICU (Boot)
PCU
SCU
NIC
Desk
Print Driver
PCL5c
PCL6
PS
PPD
For the latest Firmware and Print Driver version(s),please refer to the
Support Website.