Sharp MX-5500N / MX-6200N / MX-7000N (serv.man59) Service Manual ▷ View online

MX-7000N  DUPLEX SECTION  H – 9
g. ADU transport pass detection 2
1)
Release the lock (A), and open the right door unit (B).
2)
Remove the screws (C), and remove the paper guide (D).
3)
Remove the screws (E), and remove the pressure plate (F).
Remove the springs (G).
4)
Remove the screw (G), and remove the ADU transport path
detection unit (H). Disconnect the connector (I), and remove
the ADU transport path detection 2 (J).
h. ADU transport open/close detection
1)
Release the lock (A), and open the right door unit (B).
Unit
Parts
1
Right door unit
h
ADU transport pass detection 2
1-h
A
B
C
C
D
E
E
E
E
F
G
G
Unit
Parts
1
Right door unit
i
ADU transport open/close detection
G
J
H
I
1-h
1-i
A
B
MX-7000N  DUPLEX SECTION  H – 10
2)
Remove the screws (C). Remove the screw (D), and remove
the inner cover (E).
3)
Remove the screw (F), and remove the ADU transport open/
close detection unit (G). Disconnect the connector (H), and
remove the ADU transport open/close detection (I).
i. ADU gate solenoid
1)
Release the lock (A), and open the right door unit (B).
2)
Remove the screw (C), and remove the slide rail (D).
3)
Remove the screws (E). Remove the screw (F), and remove
the inner cover (G).
4)
Remove the screws (H), and remove the stay (I).
Unit
Parts
1
Right door unit
j
ADU gate solenoid
C
C
D
E
F
I
G
H
1-i
1-j
A
B
C
D
E
E
F
G
H
H
H
H
I
MX-7000N  DUPLEX SECTION  H – 11
5)
Disconnect the connector (J), and remove the screws (K), and
remove the ADU motor upper unit (L).
6)
Disconnect the connector (M) and remove the screws (N), and
the ADU gate solenid unit (O).
7)
Remove the screws (P), and remove the ADU gate solenoid
(Q).
j. Paper exit roller 2 (Drive)
1)
Remove the ADU gate solenoid. (Refer to the "i. ADU gate
solenoid".)
2)
Remove the screws (A), and remove the rear cover (B).
3)
Disconnect the connector (C). Remove the screws (D) and the
screws (E). Remove the right paper exit unit (F).
J
K
K
K
L
M
N
N
O
P
P
Q
1-j
Unit
Parts
Mainte
nance
1
Right door unit
k
Paper exit roller 2 (Drive)
 {
1-k
A
A
A
B
C
F
D
D
E
E
MX-7000N  DUPLEX SECTION  H – 12
4)
Remove the screws (G), and remove the front cover (H).
5)
Remove the screw (I), and remove the bearing plate (J).
Remove the E-ring (K), the gear (L), the parallel pin (M), the E-
ring (N), and the bearing (O).
6)
Remove the screw (P), and remove the earth plate (Q).
Remove the E-ring (R) and the bearing (S), and remove the
paper exit roller 2 (Drive) (T).
k. Transport roller 17 (Drive)
1)
Release the lock (A), and open the right door unit (B).
2)
Remove the screws (C). Remove the screw (D), and remove
the inner cover (E).
G
G
H
I
J
K
L
M
N
O
P
T
Q
R
S
1-k
Unit
Parts
Mainte
nance
1
Right door unit
l
Transport roller 17 (Drive)
 {
1-l
A
B
C
C
D
E
Page of 17