DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man47) Service Manual ↓ Size: 322.94 KB | Pages: 33 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man47)
Pages
33
Size
322.94 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Self diagnostics Trouble Codes
File
mx-5500n-mx-6200n-mx-7000n-sm47.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man47) Service Manual ▷ View online

MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 10
 
CE-05
FTP server directory input error
 
CE-06
POP3 server access error
 
CE-07
POP3 server authentication check 
error
 
CE-08
POP3 server timeout error
 
E6-10
Back-face shading trouble (Black 
correction) (DSPF)
 
E6-11
Shading trouble (White correction) 
(DSPF)
 
E6-14
Back-face SCAN-ASIC trouble (DSPF)
 
E7-00
System memory access error
Trouble content
The entered FTP server directory is invalid.
The entered SMB server folder is invalid.
Section
MFP
Case 1
Cause
Network cable connection trouble
Check and 
remedy
Check to insure that the network cable is securely 
connected.
Case 2
Cause
The FTP server account name registered as the 
destination or the password for the account is 
incorrect.
Check and 
remedy
Check to insure that there exits the FTP server 
directory registered as the destination.
Case 3
Cause
The SMB server account name registered as the 
destination or the password for it is incorrect.
Check and 
remedy
Check to insure that there exists the SMB server 
folder registered as the destination.
Trouble content
The specified mail server (POP3) is not found. 
(POP3 server access error)
Section
MFP
Case 1
Cause
Network cable connection trouble
Check and 
remedy
Check to insure that the network cable is securely 
connected.
Case 2
Cause
Network setup error
Check and 
remedy
1)
Check that the connected network supports 
TCP/IP protocol.
2)
Check the Web page to insure that the POP3 
server address is correctly set.
3)
If the above address is described in 
Hostname, check to insure that the DNS 
server is correctly set.
Case 3
Cause
POP3 server trouble
Check and 
remedy
Check the POP3 server for any trouble.
Trouble content
The entered POP3 server account name or the 
authentication password is invalid. (POP3 server 
authentication check error)
Section
MFP
Case 1
Cause
Network cable connection trouble
Check and 
remedy
Check to insure that the network cable is securely 
connected.
Case 2
Cause
The POP3 server account name or the password 
registered for the account is incorrect.
Check and 
remedy
Check to insure that the POP3 server account 
name or the password for the account is correct.
Trouble content
The specified mail server (POP3) does not 
respond. (POP3 server timeout error)
Section
MFP
Case 1
Cause
Network cable connection trouble
Check and 
remedy
Check to insure that the network cable is securely 
connected.
Case 2
Cause
POP3 server trouble
Check and 
remedy
Check the POP3 server for any trouble.
Trouble content
CCD black scan level abnormality when the copy 
lamp is turned off.
Section
SCU
Case 1
Cause
Installation error of the CCD unit flat cable
Check and 
remedy
Check the installing state of the flat cable to the 
CCD unit.
Case 2
Cause
CCD unit abnormality
Check and 
remedy
Check the CCD unit.
Case 3
Cause
DSPF PWB abnormality
Check and 
remedy
Check the DSPF PWB.
Trouble content
CCD white scan level abnormality when the copy 
lamp is on.
Section
SCU
Case 1
Cause
Installation error of the CCD unit flat cable
Check and 
remedy
Check the installing state of the flat cable to the 
CCD unit.
Case 2
Cause
Dirt on the mirror, the lens, or the reference white 
plate.
Check and 
remedy
Clean the mirror, the lens, or the reference white 
plate.
Case 3
Cause
Copy lamp lighting trouble
Check and 
remedy
Check the installing state of the flat cable to the 
copy lamp unit.
Case 4
Cause
CCD unit abnormality
Check and 
remedy
Check the CCD unit.
Case 5
Cause
DSPF PWB abnormality
Check and 
remedy
Check the DSPF PWB.
Trouble content
Written register value cannot be read correctly
Section
SCU
Case 1
Cause
DSPF PWB abnormality
Check and 
remedy
Check the DSPF PWB.
Trouble content
System memory trouble (Tandem memory cannot 
be guaranteed.)
Access to system memory cannot be made.
Section
MFP
Case 1
Cause
Expansion memory installation error
Check and 
remedy
Check installation of the system expansion 
memory.
Case 2
Cause
Garbled data
Check and 
remedy
1)
Use SIM60-01 to check memory read/write
2)
Replace the expansion memory (if installed.)
3)
Replace the MFPcnt PWB.
Case 3
Cause
Dirt on the memory pin
Check and 
remedy
Clean the memory pin with alcohol.
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 11
* When E7-00 is in the following combination where system mem-
ory Slot 2 (inside) and Slot 1 (outside) operate normally but a
hard error occurs.
(Combination of system memory (Slot 1, Slot 2)
 
E7-01
System data trouble
 
E7-03
HDD trouble
 
E7-04
HDD-ASIC trouble (DSK model only)
 
E7-05
Local memory access error
* Combination where local memory Slot operate normally (Refer to
E7-09) but a hard error occurs.
 
E7-06
Decode error trouble: Compression 
decode error (A compression file 
cannot decompressed.)
 
E7-09
Local memory combination error
* When the following combination (E7-09) where operation is not
performed properly is used.
No.
System memory
Operation guarantee
When turning 
on the power
Slot 2 
(Inside)
Slot 1 
(Outside)
Hard
Soft
1
Since the 
machine is not 
booted, the 
trouble display is 
not made.
2
256MB
{
{
Normal operation
3
512MB
{
{
Normal operation
4
256MB
256MB
{
{
Normal operation
5
512MB
256MB
{
{
Normal operation
6
256MB
512MB
{
{
Normal operation
7
512MB
512MB
{
{
Normal operation
8
256MB
{
{
Normal operation
9
512MB
{
{
Normal operation
Trouble content
MFP data trouble occurs.
Section
MFP
Case 1
Cause
MFP image transfer trouble
Check and 
remedy
1)
Check the connection state of the MFPcnt 
PWB connector.
2)
Replace the MFPcnt PWB.
Trouble content
HDD connection trouble
File control area data trouble (when FAT is broken)
Section
MFP
Case 1
Cause
The HDD is not properly installed to the MFPcnt 
PWB
Check and 
remedy
1)
Check installation of the HDD of the MFPcnt 
PWB.
2)
Check connection of the harness of the 
MFPcnt PWB.
3)
Use SIM62-2 and -3 to check read/write from/
to the HDD.
Case 2
Cause
The HDD does not work properly. 
Check and 
remedy
Replace the HDD.
Case 3
Cause
MFPcnt PWB trouble
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
An error occurs in the HDD-ASIC self test when 
booting.
Section
MFP
Case 1
Cause
HDD-ASIC abnormality
Check and 
remedy
Check installation of the HDD-ASIC on the MFPcnt 
PWB.
Replace the MFPcnt PWB.
Trouble content
Local memory cannot be accessed.
Section
MFP
Case 1
Cause
Local memory installation abnormality
Check and 
remedy
Check the installing state of the local memory.
Case 2
Cause
Dirt on local memory pin
Check and 
remedy
Clean the local memory pin with alcohol.
Case 3
Cause
Garbled data
Check and 
remedy
1)
Use SIM60-01 to check memory read/write.
2)
Replace the local memory.
3)
Replace the MFPcnt PWB.
Trouble content
A decode error occurs when forming an image.
Section
MFP
Case 1
Cause
Compression data abnormality
Check and 
remedy
1)
Check the installing state of the PWB. (PCI 
bus)
2)
When an error occurs during a FAX job, 
check the installation of the FAX PWB. In the 
other cases, check the installation of the 
MFPcnt PWB and HDD.
3)
Replace the MFPcnt PWB.
Case 2
Cause
HDD connection abnormality
Check and 
remedy
Check the HDD connection.
Case 3
Cause
Data are garbled in image compression/send.
Check and 
remedy
1)
Check the installation of the PWB. (PCI bus)
2)
When an error occurs during a FAX job, 
check the installation of the FAX PWB. In the 
other cases, check the installation of the 
MFPcnt PWB and HDD.
3)
Replace the MFPcnt PWB.
Case 4
Cause
MFPcnt PWB abnormality
Check and 
remedy
Replace the MFPcnt PWB.
Case 5
Cause
Local memory access error
Check and 
remedy
Check and execute remedy similarly to E7-05.
Trouble content
Combination error of installation of local slot 
memory
Section
MFP
Case 1
Cause
DIMM of other than 1GB is installed to the slot.
Check and 
remedy
Check the combination of installed DIMM.
No.
Local memory
Operation guarantee
When turning on 
the power
Slot 4
Hard
Soft
1
E7-09
2
256MB
{
E7-09
3
512MB
{
E7-09
4
1GB
{
{
Normal operation
5
1GB or more
E7-09
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 12
 
E7-10
Shading trouble (Black correction)
 
E7-11
Shading trouble (White correction)
 
E7-14
SCAN-ASIC trouble
 
E7-20
LSU BD detection trouble
 
E7-21
LSU LD deterioration trouble
 
E7-28
LSU control ASIC connection 
abnormality
 
E7-29
LSU-ASIC frequency abnormality
 
E7-50
Engine connection trouble
Trouble content
CCD black scan level abnormality when the copy 
lamp is turned off.
Section
SCU
Case 1
Cause
Installation error of the CCD unit flat cable
Check and 
remedy
Check the installing state of the flat cable to the 
CCD unit.
Case 2
Cause
CCD unit abnormality
Check and 
remedy
Check the CCD unit.
Case 3
Cause
SCU PWB abnormality
Check and 
remedy
Check the SCU PWB.
Trouble content
CCD white reference plate scan level abnormality 
when the copy lamp is on.
Section
SCU
Case 1
Cause
Installation error of the CCD unit flat cable
Check and 
remedy
Check the installing state of the flat cable to the 
CCD unit.
Case 2
Cause
Dirt on the mirror, the lens, or the reference white 
plate.
Check and 
remedy
Clean the mirror, the lens, or the reference white 
plate.
Case 3
Cause
Copy lamp lighting trouble
Check and 
remedy
Check the installing state of the flat cable to the 
copy lamp unit.
Case 4
Cause
CCD unit abnormality
Check and 
remedy
Check the CCD unit.
Case 5
Cause
SCU PWB abnormality
Check and 
remedy
Check the SCU PWB.
Trouble content
Written register value cannot be read correctly
Section
SCU
Case 1
Cause
SCU PWB abnormality
Check and 
remedy
Check the SCU PWB.
Trouble content
LSU BD signal is not detected.
Section
PCU
Case 1
Cause
Disconnection or improper connection of harness 
and connector between LD/BD PWB and LSUcnt 
PWB
Check and 
remedy
Check connection of the harness of each PWB 
inside the LSU.
Case 2
Cause
1)
Optical axis shift
2)
BK laser deterioration, power reduction
3)
BD PWB trouble
Check and 
remedy
1)
Use SIM61-1 to check the LSU operation.
2)
Replace the LSUcnt/BD PWB.
3)
If the trouble cannot be removed by the 
above 1) to 2), replace the LSU.
Trouble content
The color laser does not light up normally.
Section
PCU
Case 1
Cause
Disconnection or improper connection of harness 
and connector between LD PWB and LSUcnt PWB
Check and 
remedy
Check connection of the harness of each PWB 
inside the LSU.
Case 2
Cause
Y/M/C laser deterioration
Check and 
remedy
1)
Use SIM61-1 to check the LSU operation. 
2)
Replace the LSUcnt PWB.
3)
If the trouble cannot be removed by the 
above 1) to 2), replace the LSU.
Trouble content
Access error between the CPU of the PCU PWB 
and the LSU control ASIC
Section
PCU
Case 1
Cause
Communication connector connection trouble 
between the PCU PWB and the LSUcnt PWB 
(interface PWB), or harness trouble
Check and 
remedy
Check the connector connection between the PCU 
PWB and the LSUcnt PWB (interface PWB), or 
check the harness.
Case 2
Cause
PCU PWB or LSUcnt PWB (interface PWB) 
trouble
Check and 
remedy
Replace the PCU PWB or the LSUcnt PWB 
(interface PWB).
Trouble content
Oscillation trouble of the external oscillator used in 
LSU-ASIC and the internal oscillation circuit
Section
PCU
Case 1
Cause
Trouble of the oscillator on the LSU-ASIC PWB, 
the resistor and capacitor for the oscillation circuit, 
and the LSU-ASIC itself.
Check and 
remedy
Replace the LSUcnt PWB.
Trouble content
Unknown PWB identification information is 
detected in the PCU PWB.
Section
PCU
Case 1
Cause
A PWB which is incompatible with the machine 
specifications is connected.
Check and 
remedy
1)
Replace the PCU PWB.
2)
Replace the LSU PWB.
Case 2
Cause
A firmware which is incompatible with the machine 
specifications is used.
Check and 
remedy
Check the kind and the version of the firmware.
Case 3
Cause
LSU PWB connection trouble
Check and 
remedy
Check the LSU PWB connection.
Case 4
Cause
LSU PWB trouble
Check and 
remedy
Replace the LSU PWB.
MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 13
 
E7-60
Controller connection trouble (Engine
detection)
 
E7-61
Controller connection trouble 
(Engine)
 
E7-62
Controller connection trouble 
(Scanner)
 
E7-65
PWB information sum error 
(Controller detection)
 
E7-70
Scanner connection trouble
 
E7-75
PWB information sum error (Scanner
detection)
 
E7-80
Communication trouble between the
MFP and the scanner (MFP detection)
 
E7-90
Communication trouble between the
MFP and the PCU (MFP detection)
 
EE-EC
Auto developer adjustment trouble
(The sample level for every rotation is
other than 128 
± 10.)
Trouble content
Unknown PWB kind information is detected in the 
MFPcnt PWB.
Section
MFP
Case 1
Cause
A PWB which is not compatible with the machine 
specifications is connected.
Check and 
remedy
Replace the controller PWB.
Case 2
Cause
A firmware which is not compatible with the 
machine specifications is applied.
Check and 
remedy
Check the kind and the version of the firmware.
Trouble content
Controller connection trouble
Compatibility trouble between the controller and 
the engine
Section
MFP
Case 1
Cause
Combination trouble of the controller PWB and the 
engine
Check and 
remedy
Check the controller PWB.
Check the combination between the controller 
PWB and the engine.
Trouble content
Controller connection trouble
Compatibility trouble between the controller and 
the scanners
Section
MFP
Case 1
Cause
Combination trouble between the controller PWB 
and the scanner
Check and 
remedy
Replace the controller PWB.
Check the combination between the controller 
PWB and the scanner.
Trouble content
EEPROM PWB information sum error
Section
MFP
Case 1
Cause
1)
EEPROM device trouble
2)
EEPROM device contact failure
3)
Device access error due to electrical noises
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
Unknown PWB identification information is 
detected in the SCU PWB.
Section
SCU
Case 1
Cause
SCU PWB trouble
Check and 
remedy
Replace the SCU PWB.
Case 2
Cause
A firmware which is incompatible with the machine 
specifications is connected.
Check and 
remedy
Check the kind and the version of the firmware.
Trouble content
EEPROM PWB information sum error
Section
SCU
Case 1
Cause
1)
EEPROM device trouble
2)
EEPROM device contact failure
3)
Device access error due to electrical noises
Check and 
remedy
Replace the scanner control PWB.
Trouble content
Communication establishment error/Framing/
Parity/Protocol error
Section
MFP
Case 1
Cause
SCU PWB connector connection trouble
Check and 
remedy
Check the connector connection between the SCU 
PWB and the MFPcnt PWB.
Case 2
Cause
Harness trouble between the SCU PWB and the 
MFPcnt PWB
Check and 
remedy
Check the harness between the SCU PWB and the 
MFPcnt PWB.
Case 3
Cause
Broken connector pin of the SCU PWB mother 
board
Check and 
remedy
Check grounding of the machine.
Trouble content
Communication establishment error/Framing/
Parity/Protocol error
Section
MFP
Case 1
Cause
PCU PWB connector connection trouble
Check and 
remedy
Check the connector connection between the PCU 
PWB and the MFPcnt PWB.
Case 2
Cause
Harness trouble between the PCU PWB and the 
MFPcnt PWB
Check and 
remedy
Check the harness between the PCU PWB and the 
MFPcnt PWB.
Case 3
Cause
Broken connector pin of the PCU PWB mother 
board
Check and 
remedy
Check grounding of the machine.
Trouble content
When the automatic development adjustment is 
executed, the sample level for each rotation is not 
128 
± 10. 
<Detection only with SIM25-2, no trouble memory, 
only display>
Section
PCU
Case 1
Cause
Toner density sensor trouble, charging voltage/
developing voltage trouble, toner density trouble, 
developing unit trouble, PCU PWB trouble
Check and 
remedy
Use SIM25-2 to execute the auto developer 
adjustment.
Page of 33
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man47) service manuals if exist.