DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual ↓ Size: 3.61 MB | Pages: 127 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man46)
Pages
127
Size
3.61 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Simulation
File
mx-5500n-mx-6200n-mx-7000n-sm46.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual ▷ View online

MX-7000N  SIMULATION  7 – 7
48
1
Used to perform the copy magnification ratio (main scanning, sub scanning 
direction) adjustment. 
Adjustment
5
Used to perform the copy magnification ratio adjustment (sub scanning 
direction). When the sub scanning direction image magnification ratio is 
adjusted with SIM 48-1 and a satisfactory copy image is not obtained when 
copying by specifying a different copy magnification ratio, perform this 
adjustment.
Adjustment
Scanner section
6
Used to perform the rotation speed adjustment of each motor. 
Adjustment
49
1
Used to perform the firmware update. 
3
Used to update the operation manual in the HDD. 
Adjustment
50
1
Used to adjust the copy image position on print paper and the void area 
(image loss) in the copy mode. (The similar adjustment can be performed 
also with SIM 50-5 and SIM 50-2 (simple method). (Document table mode))
2
Used to adjust the copy image position on print paper and the void area 
(image loss) in the copy mode. (The similar adjustment can be performed 
also with SIM 50-1. This simulation. However, is simpler.)
Adjustment
5
Printer print lead edge adjustment
Adjustment
6
Used to adjust the DSPF document lead edge, and to adjust the copy image 
position and the void area (image loss) on the print paper in the copy mode. 
(The similar adjustment can be performed with SIM 50-7 (simple method).) 
(DSPF mode)
Adjustment
DSPF
7
Used to adjust the DSPF document lead edge, and to adjust the copy image 
position and the void area (image loss) on the print paper in the copy mode. 
(The similar adjustment can be performed with SIM 50-7 (simple method).) 
(DSPF mode)
Adjustment
DSPF
10
Used to adjust the print image off-center position. (Adjustment is made 
separately for each paper feed section.)
Adjustment
12
Used to perform the scan image off-center position adjustment. (The 
adjustment is made separately for each scan mode.)
Adjustment
20
Used to perform the main scanning direction manual registration adjustment.
Adjustment
21
Used to perform the sub scanning direction manual registration adjustment. 
Adjustment
22
Used to perform the main/sub scanning auto registration adjustment. 
Adjustment
24
Used to display the auto registration adjustment result (SIM 50-22).
(Do not use in the market.)
27
Used to perform the image loss adjustment of the scanned  image in the 
FAX or scanner mode 
Adjustment
28
Used to perform the OC adjustment, the BK main scanning direction 
magnification ration correction, the DSPF adjustment, and the print position 
adjustment.
Adjustment
51
1
Used to perform the transfer voltage and the separation bias voltage ON/OF 
timing adjustment. 
Adjustment/Setting
2
Used to perform the paper contact pressure adjustment for each section 
resist roller (main unit, each paper feed, duplex paper fed, DSPF paper 
feed). (When there is a considerable fluctuation in the print image position 
on print paper or a paper jam occurs, this adjustment is required.)
Adjustment/Setting
53
6
Used to perform the DSPF size width detection level adjustment. 
Adjustment
7
Used to perform the DSPF size width adjustment value setting.
Adjustment/Setting
8
Used to perform the DSPF document scanning start position adjustment. 
Adjustment
55
1
Used to perform the engine control operation specification setting. 
(Do not use this function unless 
specially required.)
2
Used to perform the scanner control operation specification setting. 
(Do not use this function unless 
specially required.)
3
Used to perform the controller operation specification setting. 
(Do not use this function unless 
specially required.)
56
1
Data transfer (Used in repairing the PWB.)
Backup
2
Used to backup the data (user authentication data, address book, etc.) in the 
EEPROM, the SRAM, and the HDD of the main unit into the USB memory 
and to transfer the data.
Backup
60
1
Used to check the operations (read/write) of the MFP control (SDRAM). 
Operation test/Check
2
Used to set the onboard SDRAM. 
(Do not use in the market.)
61
1
Used to check the polygon motor rotation and the BD signal detection. 
Operation test/Check
LSU
2
Used to set the laser power. (for printer FIERY)
Adjustment/Setting
3
Used to set the laser power. 
Adjustment/Setting
4
Used to perform self printing of the LSU position adjustment pattern. 
Adjustment
62
1
Used to format the hard disk. (Excluding the operation manual area.)
2
Used to check read/write of the hard disk (partial).
Operation test/Check
3
Used to check read/write of the hard disk (all areas).
Operation test/Check
6
Used to perform the self diagnostics of the hard disk. 
Operation test/Check
7
Used to print the hard disk self diagnostics error log. 
Operation test/Check
8
Used to format the hard disk. (Excluding the system area and the operation 
manual area)
10
Used to delete the job log data. 
Data clear
11
Used to delete the document filing data. 
Data clear
12
Used to set Enable/Disable of auto format in a hard disk trouble. 
Setting
13
Used to format the hard disk. (only the operation manual area)
Main
Sub
Function (Purpose)
Purpose
Section
MX-7000N  SIMULATION  7 – 8
63
1
Used to check the shading correction result. 
Adjustment/Setting/Operation data 
check
Scanner
2
Used to perform shading. 
Adjustment
3
Used to perform scanner color balance and color coefficient auto 
adjustment.
Adjustment/Setting
Scanner
5
Used to perform the scanner color balance and the color coefficient auto 
adjustment. 
Adjustment/Setting
6
Used to perform the engine color balance auto adjustment pattern setting. 
Adjustment/Setting
7
Used to perform the auto density setting of the engine auto adjustment 
scanner target value. (Servicing)
Adjustment/Setting
8
Used to perform the initial value reset of the engine auto adjustment scanner 
target value. (Servicing)
Adjustment/Setting
11
Used to set the reference scanner target value for the engine auto density 
adjustment. 
Adjustment/Setting
64
1
Used to perform the self print. (Color mode)
Operation test/Check
2
Used to print the density adjustment pattern. 
Operation test/Check
3
Used to perform self print (monochrome mode).
Operation test/Check
4
Used to perform the printer self print.
* When FIERY is supported, SIM is not displayed.
Operation test/Check
5
Used to perform the printer self print (PCL).
* When FIERY is supported, SIM is not displayed.
Operation test/Check
6
Used to perform the printer self print (PS).
* When FIERY is supported, SIM is not displayed.
Operation test/Check
65
1
Used to perform the touch panel (LCD display) detection position 
adjustment. 
Adjustment
Operation panel section 
2
Used to check the touch panel (LCD display) detection position adjustment 
result. 
Operation check/test
5
Used to check the operation panel key input. 
Operation check/test
66
1
Used to change and check the soft switch setting.
Setting
2
Used to clear the soft switch and set the default value.
Data clear
3
Used to check the operation (read/write) of the FAX PWB memory. 
Operation test, check
FAX
4
Used to check the output operation (MODEM operation) of data signal in 
each data output mode of FAX. Send level: MAX
Operation check, test
FAX
5
Used to check the output operation (MODEM operation) of data signal in 
each data output mode of FAX. Send level: Soft switch setting
Operation test, check
FAX
6
Used to print the confidential pass code.
User data output, check
FAX
7
Used to output the image memory data (memory send and receive).
* The confidential receive contents are also outputted.
User data output, check
FAX
8
Used to check the output operation (audio output IC operation check) of the 
various audio signals of FAX. Send level: MAX
Operation test, check
FAX
9
Used to check the output operation (audio output IC operation) of various 
audio signals of FAX. Send level: Soft switch setting
Operation test, check
FAX
10
Used to clear all the data (memory receive and send) of the image memory.
* The confidential receive data are cleared simultaneously.
Data clear
FAX
11
Used to check the output operation (MODEM operation) in the FAX G3 
mode 300bps. Send level: MAX
Operation test, check
FAX
12
Used to check the output operation (MODEM operation) in the FAX G3 
mode 300bps. Send level: Set with the soft switch.
Operation test, check
FAX
13
Used to set the number for the FAX dial signal output test. (In the dial signal 
output test with SIM66-14 - 16, the dial number set with this simulation is 
outputted.)
Setting
FAX
14
Used to set the make time in the FAX pulse dial mode (10PPS) and to 
execute the dial signal output test. (The signal of the dial number set with 
SIM66-13 is outputted.)
Setting/Operation test, check
FAX
15
Used to set the make time in the FAX pulse dial mode (20PPS) and to 
execute the dial signal output test. (The signal of the dial number set with 
SIM 66-13  is outputted.)
Setting/Operation test, check
FAX
16
Used to perform the dial signal (DTMF) output test in the FAX tone dial 
mode. (The signal of the dial number set with SIM 66-13 is outputted.) 
The send level can be set to an optional level.
Setting/Operation test, check
FAX
17
Used to perform the dial signal (DTMF) output test in the FAX tone dial 
mode. Send level: MAX
Operation test, check
FAX
18
Used to perform the dial signal (DTMF) output test in the FAX tone dial 
mode. Send level: Set with the soft switch.
Operation test, check
FAX
19
Used to backup the address book data stored in the HDD. (Backup to the 
Flash ROM)
Backup
20
Used to transfer the address book data stored in the Flash ROM. (Transfer 
to HDD)
Data transfer
21
Used to print information abut FAX (various registrations, communication 
management, file management, system errors, protocols).
Adjustment, setting, operation data 
check
FAX
24
Used to clear the FAST memory data.
Clear
FAX
25
Used to register a FAX number for MODEM dial-in.
Setting
FAX
26
Used to register an external telephone number for MODEM dial-in.
Setting
FAX
Main
Sub
Function (Purpose)
Purpose
Section
MX-7000N  SIMULATION  7 – 9
66
29
Used to clear the data related to the address book (one-touch registration, 
FTP/ Desktop extension, group extension, program registration, interface 
memory box, meta data, Inbound Routing, Document Admin table).
Data clear
30
Used to check a change in the TEL/LIU status.
Operation test, check
FAX
31
Used to set the TEL/LIU output port.
Operation check
FAX
32
Used to check the received data (fixed data) from the line.
Operation test, check
FAX
33
Used to detect the line signals (BUSY TONE/CNG/CED/FNET/DTMF).
Operation test, check
FAX
34
Used to measure the communication time of the send test image data. 
Operation test, check
FAX
36
Used to perform the interface check between the MFP controller and the 
MDMC. (Data line or command line check)
Operation test, check
FAX
39
Used to set the destination.
Setting
FAX
42
Used to rewrite the power control program again to the FAX BOX.
Setting
FAX
43
Used to write the adjustment value of the power control program to the FAX 
BOX.
Setting
FAX
67
17
Used to set the printer controller memory clear and default value.
Setting
24
Used to perform the printer setting of auto color calibration. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
25
Used to perform the manual correction setting of the printer engine color 
balance. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
26
Used to perform the reference scanner target value setting of the printer 
engine auto density adjustment. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
27
Used to perform the scanner target value registration of the printer engine 
auto density adjustment.
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
28
Used to perform the scanner target value registration of the printer engine 
auto adjustment.
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
30
Used to perform delivery setting of the main unit calibration data and the 
process correction data to a client PC. (for GDI printer)
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
31
Used to clear the printer calibration value. 
* When FIERY is supported, SIM is not displayed.
Data clear
32
Used to perform the screen/color select function setting for each object. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
33
Used to perform the gamma correction (for PCL) between printer screens. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
33
Used to perform gamma correction (for GDI) between printer screens. 
* When FIERY is supported, SIM is not displayed.
Adjustment/Setting
Main
Sub
Function (Purpose)
Purpose
Section
MX-7000N  SIMULATION  7 – 10
3. Details of simulation
 
1
 
1-1
Purpose
Operation test/Check
Function (Purpose) Used to check the operations of the scan-
ner (read) unit and its control circuit.
Section
Optical (Image scanning)
Operation/Procedure
1)
Select the operation mode and the magnification ratio with the
touch panel key. 
2)
Press [EXECUTE] key.
The scanner performs scanning at the speed corresponding to
the operation mode.
 
1-2
Purpose
Operation test/Check
Function (Purpose) Used to check the operation of sensor in
the scanning (read) section and the related
circuit.
Section
Optical (Image scanning)
Operation/Procedure
The operating status of the sensor is displayed. 
* When "MHPS" is highlighted, the scanner unit is in the home
position.
 
1-5
Purpose
Operation test/Check
Function (Purpose) Used to check the operations of the scan-
ner (read) unit and its control circuit.
Section
Optical (Image scanning)
Operation/Procedure
1)
Select the operation mode and the magnification ratio with the
touch panel key. 
2)
Press [EXECUTE] key.
The scanner performs scanning at the speed corresponding to
the operation mode.
 
2
 
2-1
Purpose
Operation test/Check
Function (Purpose) Used to check the operations of the auto-
matic document feeder unit and the control
circuit.
Section
DSPF
Operation/Procedure
1)
Select the operation mode and the magnification ratio with the
touch panel key. 
2)
Press [EXECUTE] key.
The DSPF repeats paper feed, transport, and paper exit oper-
ations according to the operation mode.
When [EXECUTE] key is pressed, the operation is terminated.
Key 
display
Scan 
magnification ratio
Selectable magnification 
ratios
Default 
value
50
50%
Color: 50%, 100%, 200%
Black and white (High speed):
100%, 200%
Black and white (Low speed):
50%, 100%, 200%
100%
100
100%
200
200%
CLOSE
BLACK(SLOW)
SIMULATION NO.01-01
SCANNER CHECK
TEST
EXECUTE
150
200
ZOOM
100
BLACK(FAST)
COLOR
25
50
100
300
400
SCANNER SENSOR CHECK
CLOSE
SIMULATION NO.01-02
TEST
1/1
MHPS
Key 
display
Scan 
magnification ratio
Selectable magnification 
ratios
Default 
value
50
50%
Color: 50%, 100%, 200%
Black and white (High speed):
100%, 200%
Black and white (Low speed):
50%, 100%, 200%
100%
100
100%
200
200%
Key 
display
Scan 
magnification ratio
Selectable magnification 
ratios
Default 
value
50
50%
Color: 50%, 100%, 200%
Black and white (High speed):
100%, 200%
Black and white (Low speed):
50%, 100%, 200%
100%
100
100%
200
200%
CLOSE
BLACK(SLOW)
SIMULATION NO.01-05
SCANNER CHECK
TEST
EXECUTE
150
200
ZOOM
100
%
BLACK(FAST)
COLOR
25
50
100
300
400
CLOSE
BLACK(SLOW)
SIMULATION NO.02-01
DSPF AGING
TEST
EXECUTE
150
200
ZOOM
100
%
BLACK(FAST)
COLOR
25
50
100
300
400
Page of 127
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man46) service manuals if exist.