DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man29) Service Manual ↓ Size: 3.08 MB | Pages: 9 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man29)
Pages
9
Size
3.08 MB
Type
PDF
Document
Peripheral
Brand
Device
Copying Equipment / MX-FNX4 4K Saddle Stitch Finisher-Installation Manual
File
mx-5500n-mx-6200n-mx-7000n-sm29.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man29) Peripheral ▷ View online

MX-7000N  MX-FNX4  8 – 6
7)
Remove the screws, and remove the rear lower cover.
8)
Remove the fixing tapes.
9)
Loosen the caster fixing screws.
10) Remove the screw, and remove the spanner installed inside
the front door.
11) Turn the bolt for which the adjustment is necessary, and adjust
to become it within the range of specification.
12) Check to insure that the upper and lower clearances between
the main unit and the finisher are even.
MX-7000N  MX-FNX4  8 – 7
13) Tighten the caster fixing screws so that the indicator scale is
fit.
14) Install the rear lower cover with the fixing screws.
15) Install the front lower cabinet 2 with the fixing screws.
16) Install the front lower cabinet 1 with the fixing screws.
17) Attach the cabinet fixing screw.
18) Install the spanner for adjustment to inside the front door with
screw.
19) Close the front door.
MX-7000N  MX-FNX4  8 – 8
E. Connection of the saddle stitch finisher
1)
Engage the saddle stitch finisher to the main unit.
2)
Open the front door of saddle stitch finisher.
3)
Fix the saddle stitch finisher to the main unit with the step
screw B (Package part No. 4).
4)
Close the front cover.
5)
Remove the screw, and remove the connector cover on rear
side of the finisher.
6)
Install the Step screw B (Package part No. 4).
7)
Attach the connector cover on rear side of the finisher with the
fixing screw.
MX-7000N  MX-FNX4  8 – 9
F. Connection of connector to the main unit
1)
Connect two connectors of the saddle stitch finisher to the
main unit, and tighten the screws.
G. Staple position label attachment
1)
Attach the label to the position indicated in the figure.
[For scanner] (Package part No. 9)
[For DSPF] (Package part No. 10)
H. Turn ON the main power switch of the main 
unit
1)
Connect the power plug of the main unit into the power outlet.
2)
Open the front cabinet of the main unit. Turn ON the power
switch in the front cabinet.
3)
Turn ON the power switch on the operation panel.
Edge of R part in corner
Edge of R part in corner
Reference line of
sticking label on.
* The corner of the upper
cabinet rear part
"ON"
ON
ON
Page of 9