Precautions
 
Power Supply Cord Notice
CAUTION: 
 
The power supply cord is used as the main disconnect device. Ensure that the 
socket-outlet is located/installed near the equipment and is easily accessible.
 
ACHTUNG: 
 
Der Netzstecker dient zur sicheren Trennung des Gerätes von der Stromversorgung. Stellen Sie sicher, dass sich die 
Steckdose in unmittelbarer Nähe des Gerätes befindet und leicht zugänglich ist.
 
ATTENTION : 
 
Le cordon d’alimentation doit être débranché pour une mise hors tension totale du produit. La prise de courant 
doit être située ou installée à proximité du matériel et être facilement accessible.
 
Lithium Battery Notice
CAUTION: 
 
Danger of explosion if battery is replaced with incorrect type. Replace only 
with the same type recommended by the manufacturer. Dispose of used batteries 
according to the manufacturer’s instructions.
 
ACHTUNG: 
 
Es besteht Explosionsgefahr, wenn die Batterien durch einen falschen Batterientyp ersetzt werden. Ersetzen Sie sie 
deshalb nur durch denselben, vom Hersteller empfohlenen Typ. Entsorgen Sie leere Batterien entsprechend den Anweisungen 
des Herstellers.
 
ATTENTION : 
 
IIl y a danger d’explosion en cas de remplacement avec le mauvais type de batterie. Remplacer uniquement avec 
une batterie du même type recommandé par le constructeur. Les batteries usagées doivent être jetées conformément aux 
instructions du fabricant.
 
Short Circuit Protection
WARNING: 
 
This product relies on the building’s installation for short-circuit 
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 
15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-
carrying conductors).
 
WARNUNG: 
 
Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. 
Stellen Sie sicher, dass eine Sicherung oder ein Unterbrecher von nicht mehr als 240 V Wechselstrom, 10 A (bzw. in den USA 
120 V Wechselstrom, 15 A) an den Phasenleitern (allen stromführenden Leitern) verwendet wird.
 
ATTENTION : 
 
La protection contre les courts-circuits (surtension) du produit est assurée par l’installation électrique du local où 
il est installé. S’assurer qu’un fusible ou un disjoncteur inférieur ou égal à 120 V CA, 15 A aux Etats-Unis (240 V CA, 10 A 
dans les autres pays) est utilisé pour les conducteurs de phase (conducteurs de courant).
 
5
Precautions
F
 
IGURE
 
 B
 
Fiery X3eTY2 exploded view
i
Key
1. Cover
2. CPU clamp
3. CPU fan
4. CPU heatsink
5. DIMM
6. CPU
7. Battery
8. Motherboard
9. Interface board 
10. Service board cable
11. HDD SATA data cable
12. Power supply
13. HDD bracket
14. HDD (hard disk drive)
15. Exhaust fan
16. Service board
17. Pan
N
OTE
The CPU cooling 
assembly shown here may differ 
from the cooling assembly 
installed in your system. For 
more information, see page 24.
4
1
8
10
9
5
2
3
7
11
12
13
14
15
16
6
17
 
6
Accessing the Fiery X3eTY2
 
Accessing the Fiery X3eTY2
 
To service the Fiery X3eTY2, you must perform the following tasks:
• Shut down the Fiery X3eTY2; power off both the Fiery X3eTY2 and the MFP.
• Remove the Fiery X3eTY2 from the MFP.
• Open the Fiery X3eTY2.
 
T
 
O
 
 
 
SHUT
 
 
 
DOWN
 
 
 
THE
 
 F
 
IERY 
 
X3
 
E
 
TY2
CAUTION:
 
Before you touch any parts inside the Fiery X3eTY2, make sure to wear an 
ESD grounding wrist strap and follow all ESD safety precautions. 
 
1.
Complete the steps listed below for your MFP model:
F
 
IGURE
 
 C
 
Fiery Settings screen
 
MX-7000/6200/5500
MX-4500/3500
 
• Press the Copy tab on the MFP touch 
panel.
• Press the Fiery icon at the bottom of 
the touch panel.
• Press Fiery Settings.
The Fiery Settings screen appears.
• Press the System Settings button on 
the MFP.
• On the touch panel, press Admin 
Password and then press Password.
• On the touch panel, use the keyboard 
to enter the administrator password for 
the MFP. Press OK and then press OK 
again at the next screen.
This password is not the same as the 
administrator password for the 
Fiery X3eTY2.
• At the System Settings screen, use the 
arrows to scroll to Printer Settings and 
press Printer Settings.
• Press Fiery Settings.
The Fiery Settings screen appears.
Server Name
Idle
##### MB              x.x
Info
Line selection 
buttons
Up button
Down button
Menu button
 
7
Accessing the Fiery X3eTY2
2.
Make sure that the Fiery Settings screen reads Idle.
 
If Printing, Processing, or RIPping appears, the Fiery X3eTY2 is processing a job, and 
you must wait until the system finishes and reaches Idle state.
 
3.
Press the menu button to display the Functions menu.
4.
Use the down button to scroll to Shut Down. Use the line selection button to select 
Shut Down.
 
The Shut Down menu appears with the following options:
• Restart Server: Resets the Fiery X3eTY2 server software without resetting the 
underlying operating system.
• Shut Down System: Shuts down the Fiery X3eTY2 properly so that you can safely 
power off the Fiery X3eTY2.
• Reboot System: Resets both the Fiery X3eTY2 and the underlying operating system, 
and then reboots the Fiery X3eTY2.
 
5.
Use the line selection button to select Shut Down System.
6.
When a message appears prompting you to check the controller power switch or power 
off the controller, press OK.
7.
Move the power switch on the Fiery X3eTY2 to the Off (O) position (see Figure D).
F
 
IGURE
 
 D
 
Fiery X3eTY2 power panel
 
8.
Power off the MFP using the secondary power switch on the Control Panel, and then the 
main power switch inside the front compartment.
N
 
OTE
 
:
 
If you are recycling power, wait at least five seconds before powering back on.
Service switches
(may be covered)
Power switch
LED display
(may be covered)
Power connector
Page of 99