27
Removing and replacing Fiery X3eTY2 components
T
O
 
REPLACE
 
THE
 CPU 
COOLING
 
ASSEMBLY
1.
Install the CPU cooling assembly:
• For the Type A cooling assembly, see the instructions below.
• For the Type B cooling assembly, see page 28.
Type A:
• Make sure the levers on the
clamp are in the open position (spine 
up).
• Align the heatsink so that the 
fan cable is near the CPU fan 
connector on the motherboard 
(FAN1). 
• Place the heatsink on the CPU and 
inside the bracket. 
Make sure the heatsink is fully seated 
in the bracket on all 
sides.
• Press down on the clamp until all four 
hooks engage the slots in the bracket. 
Avoid using excessive force when 
pressing down on the clamp. 
• Close the levers simultaneously.
Closing the levers simultaneously 
applies clamping force equally over 
the CPU and bracket.
Bracket
Clamp
Hooks
(2 of 4)
Lever open
Lever open
CPU
Heatsink
Slot
(1 of 4)
Engage all four hooks,
and then close both 
levers simultaneously.
Lever closed
Lever closed
28
Removing and replacing Fiery X3eTY2 components
Type B:
• Make sure the fan is securely attached 
to the top of the heatsink. 
N
OTE
In most cases, the fan is already 
attached to the heatsink. 
• Align the heatsink so that the fan 
cable is near the CPU fan connector 
(P1 FAN1) on the motherboard. 
• Place the heatsink on the CPU and 
inside the bracket. 
Make sure the heatsink is fully seated 
in the bracket on all sides.
• Insert the hook of the stationary clip 
arm into a bracket slot.
• Allow the clip to lay across the groove 
in the top of the heatsink.
• Hook the movable clip arm into the 
bracket slot on the other side of the 
heatsink. 
• Orient the other clip in the opposite 
direction and then install by repeating 
the previous step. The “opposite” 
orientation helps apply clamping 
force equally over the heatsink.
Avoid using excessive force when 
pressing down on the thumb tabs.
Thumb pad
Movable arm hooking
into bracket slot
Fan
Fan cable
Stationary
clip arm
Hook
Movable
clip arm
Hook
Groove
Bracket
Stationary
arm
Thumb pad
(opposite orientation)
Clip
29
Removing and replacing Fiery X3eTY2 components
2.
Connect the CPU fan cable to the motherboard connector FAN1. 
If you are installing a replacement CPU cooling assembly, secure the slack in the fan cable 
using a tie-wrap, if necessary. The tie-wrap prevents the fan cable from interfering with 
the CPU fan. Also, make sure the connector on the cable is securely attached to 
connector FAN1 on the motherboard.
3.
Replace the 4-pin power cable to its connector on the motherboard (see Figure G on 
page 11).
4.
Reassemble the Fiery X3eTY2 and verify functionality (see page 42).
CPU
Use the following procedures to remove and replace the CPU on the motherboard.
The CPU is installed in a Zero Insertion Force (ZIF) socket on the motherboard. Before 
you can remove the CPU from its socket you need to remove the cooling assembly from 
the CPU socket, as described on page 24. 
This section includes the following topics:
• “To remove the CPU” on page 30
• “To replace the CPU” on page 31
30
Removing and replacing Fiery X3eTY2 components
T
O
 
REMOVE
 
THE
 CPU
1.
Access and open the Fiery X3eTY2, as described on page 8.
2.
Remove the CPU cooling assembly, as described on page 24.
3.
Lift the CPU socket lever to release the CPU from the socket.
To release the CPU, flex the lever away from the retention post on the socket, and then 
lift the lever all the way up.
F
IGURE
 P
Removing/replacing a CPU
4.
Grasp the CPU by its edges and carefully lift it from the socket.
CPU
Arrow
Retention post
CPU socket
Pin 1