Removing and replacing Fiery X3eTY2 components
Removing and replacing Fiery X3eTY2 components
Before you replace costly components, verify the connections between the MFP and the
Fiery X3eTY2. Also, verify the connections of each replaceable Fiery X3eTY2
component. For more information about troubleshooting, see page 65.
Fiery X3eTY2. Also, verify the connections of each replaceable Fiery X3eTY2
component. For more information about troubleshooting, see page 65.
The following sections describe how to remove and install replaceable parts on the
Fiery X3eTY2:
Fiery X3eTY2:
• Interface board
• DIMM
• Battery
• Motherboard
• Service board
• CPU cooling assembly
• CPU
• Chassis fan
• Power supply
• Hard disk drive (HDD)
For information about replacing other components, see the MFP manufacturer’s service
documentation.
documentation.
C
AUTION
:
Wear an ESD grounding wrist strap and follow standard ESD (electrostatic
discharge) precautions while performing the following procedures.
13
Removing and replacing Fiery X3eTY2 components
Interface board
The interface board is installed in the PCI1 connector on the motherboard, and is used
to process image data from the Fiery X3eTY2 to the MFP. Use the following procedures
to remove and replace the interface board.
to process image data from the Fiery X3eTY2 to the MFP. Use the following procedures
to remove and replace the interface board.
T
O
REMOVE
THE
INTERFACE
BOARD
1.
Access and open the Fiery X3eTY2, as described on page 6.
2.
Remove the two mounting screws that secure the interface board to the side of the
Fiery X3eTY2 pan. Then remove the screw that secures the interface board to the board
guide (see Figure H).
Fiery X3eTY2 pan. Then remove the screw that secures the interface board to the board
guide (see Figure H).
Set aside the screws so that you can replace them later.
F
IGURE
H
Removing the interface board
3.
Remove the interface board from its connector on the motherboard.
Grasp the board at the front and back edge and gently pull the board straight out of its
connector on the motherboard. Make sure that the interface connector clears the cutout
in the pan.
connector on the motherboard. Make sure that the interface connector clears the cutout
in the pan.
Place the board on an antistatic surface.
Mounting
screws
screws
Interface board
Board guide
and screw
14
Removing and replacing Fiery X3eTY2 components
T
O
PREPARE
A
REPLACEMENT
INTERFACE
BOARD
If you are replacing the interface board with a new one, you must transfer the security
chip from the old board to the new board. If you fail to transfer the security chip before
installing the new MFP interface board, the Fiery X3eTY2 will lose optional software
features such as Secure Erase, as well as any third-party fonts installed by the customer.
chip from the old board to the new board. If you fail to transfer the security chip before
installing the new MFP interface board, the Fiery X3eTY2 will lose optional software
features such as Secure Erase, as well as any third-party fonts installed by the customer.
1.
Use a PROM extractor to remove the security chip from socket U2 on the old interface
board (see Figure I).
board (see Figure I).
F
IGURE
I
Detail of interface board (component side)
2.
Inspect the security chip and carefully straighten any bent pins with needlenose pliers.
Interface connector
To PCI1 on motherboard
Security chip (U2)
Mounting bracket
15
Removing and replacing Fiery X3eTY2 components
3.
Unpack the replacement interface board, and install the security chip in socket U2 on
the new board.
the new board.
N
OTE
:
Be sure to align the small notch in the security chip with the notch in the outline
that appears inside socket U2 (see Figure J). If you install the security chip incorrectly,
you may corrupt the security chip and/or the interface board.
you may corrupt the security chip and/or the interface board.
F
IGURE
J
Aligning the security chip
Proceed to “To replace the interface board”.
U2
Security chip
Align notches