MX-LCX2  SIMULATION  9 – 2
 
4-5
Purpose
Operation test/Check
Function (Purpose) Used to check the operations of the clutch
(LTRC) in the LCC and the monitor.
Section
Large capacity tray (LCC)
Operation/Procedure
1) Press LTRC key to check the sync signal.
When normal: ON When abnormal: OFF
2) Press the highlighted LTRC key to check the sync signal.
When normal: OFF When abnormal: ON
 
15
 
15--
Purpose
Clear/cancel (Trouble etc.)
Function (Purpose) Used to cancel the self-diag "U6-09 F3-12,
F3-22(largecapacity paper feed tray, paper
feed tray 1, 2)" trouble.
Section
LCC
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key to execute cancellation of the trouble.
SIMULATION NO.04-05
TEST
LCC SYNCRONIZING SIGNAL CHECK
LTRC
LTRC OFF
:
1/1
CLOSE
SIMULATION NO.15
TEST
LCC TROUBLE CANCELLATION
CLOSE
EXECUTE
ARE YOU SURE?
YES
NO
MX-LCX2  SELF DIAG MESSAGE AND TROUBLE CODE  10 – 1
MX-LCX2
Service Manual
 
[10] SELF DIAG MESSAGE AND 
TROUBLE CODE
1. Self diag
A. General
When a trouble occurs in the machine or when the life of a consum-
able part is nearly expired or when the life is expired, the machine
detects and displays it on the display section or notifies to the user
or the serviceman by voice messages. This allows the user and the
serviceman to take the suitable action. In case of a trouble, this fea-
ture notifies the occurrence of a trouble and stops the machine to
minimize the damage.
B. Function and purpose
1) Securing safety. (The machine is stopped on detection of a
trouble.)
2) The damage to the machine is minimized. (The machine is
stopped on detection of a trouble.)
3) By displaying the trouble content, the trouble position can be
quickly identified. (This allows to perform an accurate repair,
improving the repair efficiency.)
4) Preliminary warning of running out of consumable parts allows
to arrange for new parts in advance of running out. (This
avoids stopping of the machine due to running out the a con-
sumable part.)
C. Self diag message kinds
• The self diag messages are classified as shown in the table
below.
D. Self diag operation
(1) Self diag operation and related work flow
The machine always monitors its own state.
When the machine recognizes a trouble, it stops the operation and
displays the trouble message.
A warning message is displayed when a consumable part life is
nearly expired or is expired.
When a warning message is displayed, the machine may be or
may not be stopped.
The trouble messages and the warning messages are displayed by
the LCD.
Some trouble messages are automatically cleared when the trou-
ble is repaired. Some other troubles must be cleared by a simula-
tion.
Some warning messages of consumable parts are automatically
cleared when the trouble is repaired. Some other warning mes-
sages must be cleared by a simulation.
Class 1
User
Warning of troubles which can be recovered by the 
user. (Paper jam, consumable part life expiration, 
etc.)
Service
man
Warning of troubles which can be recovered only by 
a serviceman. (Motor trouble, maintenance, etc.)
Other
-
Class 2
Warning
Warning to the user, not a machine trouble 
(Preliminary warning of life expiration of a 
consumable part, etc.)
Trouble
Warning of a machine trouble. The machine is 
stopped.
Other
-
Troubleshoot the cause.
YES
NO
Detects/analyzes
the content.
Trouble/Warning
Warning
Trouble
The machine is stopped.
The content is displayed.
Trouble/Warning
Warning
A consumable
part has reached
its lifetime.
Trouble
Replace or supply
the consumable part.
Cancel the self-
diagnostic message with
the diagnostics
(test commands).
Reset
Standby state
Monitors the machine
conditions.
Repair
MX-LCX2  SELF DIAG MESSAGE AND TROUBLE CODE  10 – 2
2. Trouble code list
3. Trouble code details
 
U6-09 LCC lift motor trouble
 
U6-20 LCC communication trouble
 
U6-21 LCC transport motor trouble
 
U6-22 LCC 24V power abnormality
 
U6-51 LCC incompatibility trouble
No.
MAIN 
CODE
SUB 
CODE
Title (Content)
Section
Operation mode
Countermeasure (Remedy)
Note
1
U6
09
Lift motor trouble
LCC
Tray lift-up
Check connection.
2
20
Communication trouble
LCC
LCC communication
Turn OFF/ON the power.
3
21
Transport motor trouble
LCC
Paper feed
Check connection.
4
22
24V trouble
LCC
Power ON
Check connection.
5
51
LCC incompatibility trouble
LCC
Power ON
Check connection.
Trouble content
• The encoder input value is not changed in 
0.2sec (1st time)/0.5sec (2nd time and later) 
after rotation of the motor.
• The motor is rotated for 24sec or more.
Section
PCU
Case 1
Cause
Sensor trouble, LCC control PWB trouble, gear 
breakage, lift motor trouble
Check 
and 
Remedy
Use SIM4-2 and 4-3 to check the operation of the 
sensor and the lift motor. Use SIM15 to cancel the 
trouble.
Trouble content
LCC communication error. Communication line test 
error after turning ON the power or canceling the 
exclusive simulation. LCC and machine model 
codes discrepancy error
Section
PCU
Case 1
Cause
Connector and harness connection trouble or 
disconnection, LCC control PWB trouble, control 
(PCU) PWB trouble, malfunction due to electrical 
noises
Check 
and 
Remedy
Turn OFF/ON the power to cancel the trouble. 
Check the connector and the harness of the 
communication line.
Trouble content
After passing 1 sec from turning ON the motor, the 
lock state of the motor lock signal is detected 
continuously for 1 sec.
Section
PCU
Case 1
Cause
Motor lock, motor RPM abnormality, an overcurrent 
to the motor, LCC control PWB trouble
Check 
and 
Remedy
Use SIM4-3 to check the operation of the transport 
motor.
Trouble content
DC24V power is not supplied to LCC.
Section
PCU
Case 1
Cause
Connector and harness connection trouble or 
disconnection, LCC control PWB trouble, power 
unit trouble
Check 
and 
Remedy
Check the connector and the harness of the power 
line. Check that the power unit and the LCC control 
PWB is of 24V.
Trouble content
Detection of LCC connection which is incompatible 
with the MX-5500N/6200N/7000N series.
Section
PCU
Case 1
Cause
Connection of the LCC, which is incompatible with 
the MX-5500N/6200N/7000N series is detected.
Check 
and 
Remedy
Connect the MX-LCX2.
MX-LCX2  ELECTRICAL SECTION  11 – 1
MX-LCX2
Service Manual
 
[11] ELECTRICAL SECTION
1. Electronic/mechanical parts relationship diagram
SMP-03V-NC
LRE
+5V
1
GND2
2
3
+5V
B8B-PH-K-S
CN-B
GND2
3
1
6
4
8
2
7
5
(/LTLS)
+24V
+5V
GND2
LRE
LDD
3
2
1
2
3
1
SMR-03V-N
LDD
+5V
1
GND2
2
3
3
2
1
2
3
1
SMP-03V-NC
SMR-03V-N
10
16
14
1
18
12
5
+5V
GND1
11
17
/LTRC
7
GND2 GND2
/LPFS
+24V
CN-C
+24V
15
+5V
4
13
/LTOD
20
22
9
B24B-PHDSS-B
2
8
/LPED
+5V
23
+5VR
24
3
/LPFD
+5V
19
GND2
/LPFC
21
GND2
GND2
GND2
+5V
EXIN2 EXIN1
LUD
6
9
10
11
12
6
3
SMP-18V-NC
5
1
7
2
8
4
15
16
17
18
13
14
+5V
1
2
3
/LTOD
GND2
1
1
2
2
3
3
SMR-03V-N
SMP-03V-NC
179228-3
SMP-03V-NC
SMR-03V-N
ELR-03V
1
2
LLM
LLM(GND)
5
4
LPFM-T
+24V
GND1
/LPFM-EN
/LPFM-CLK
2
3
PHR-5
1
+5V
3
2
1
LCD
GND2
1
3
ELP-03V
2
3
2
1
1
3
2
2
1
3
N.C.
+5V
LLM
5
GND2
6
9
N.C.
7
B14B-PHDSS-B
2
8
3
GND2
/LPFM-EN
LCD
4
LPFM-T
10
LLM(GND)
11
/LPFM-CLK
CN-E
1
GND1
1 2
GND1
13
+24V(LOSW)
14
7
12
11
10
9
3
5
2
SMR-18V-N
2
3
6
8
1
4
1
2
1
2
1
GND2
1
/LPED
2
LUD
+5V
1
GND2
2
3
1
+5V
3
3
2
13
14
15
16
17
18
SMP-03V-NC
SMR-02V-N
SMP-02V-NC
SMR-03V-N
GND2
1
3
+5VR
2
/LPFD
SMR-03V-N
SMP-03V-NC
3
2
1
2
1
3
/LTRC
3
2
1
+24V
N.C.
PHR-3
CZHR-03V-S
PHR-3
PHR-3
2 1
3
4
5
6
+24V(L24VM)
+24V(LLSW)
GND2
CN-D
B10B-PHDSS-B
7
9
10
GND2 GND2
8
+24V(LDSW)
GND2
GND2
+24V(LLSW)
+24V(L24VM)
NC
3
2
1
COM
ON
NC
3
2
1
COM
ON
1
2
1
2
ELR-04NV
ELP-04NV
4
3
4
3
PS-187-3V
FPS-187
LRE
LDD
LTOD
LTRC
LUD
LPED
LLSW
LDSW
LLM
LPFM
LCD
LPFS
LPFC
LPFD
LCC MAIN PWB CR