DOWNLOAD Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Service Manual ↓ Size: 341.39 KB | Pages: 5 in PDF or view online for FREE

Model
MX-4100N MX-4101N MX-5000N MX-5001N (serv.man131)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
341.39 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / NOTIFICATION OF REVISED DESCRIPTIONS IN THE INSTALLATION MANUAL FOR MX-FR11U (DSK)
File
mx-4100n-mx-4101n-mx-5000n-mx-5001n-sm131.pdf
Date

Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Service Manual / Technical Bulletin ▷ View online

Date:  
18
th
 November 2009 
Model:  
MX4100N – MX5000N 
  MX4101N 
– 
MX5001N 
Ref.:  
037 
Colour:  
White 
Page:  
 1 of 5
 
 
 
 
 
 
 
 
TECHNICAL BULLETIN 
 
 
 
 
 
NOTIFICATION OF REVISED DESCRIPTIONS IN THE 
INSTALLATION MANUAL FOR MX-FR11U (DSK)
 
 
 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-731 
 
 
1. Model Name: 
  MX4100N – MX4101N – MX5000N – MX5001N 
 
2. General:   
  This is to notify about revisions in the installation manual [16] MX-FR11/FR11U. 
 
(Primary reasons) 
 Correction of errors in descriptions.  
 Addition of work processes along with the addition of the certified model MX-FR11. 
 
(Major revisions) 
 Name of parts provided in the same package, 4) Before change: Installation procedures 
 After change: Notes (MX-FR11 only) 
 Name of parts provided in the same package, 6) Certificate label (MX-FR11 only) added. 
 G. Addition of work process "Specifying settings of data security function." 
 H. Addition of "Affixing the provided certificate label onto the front of main unit" (MX-FR11 
only). 
 Addition of accompanying items and correcting errors on MX-FR10. 
 
3. Description: 
  Refer to attached document for details of revisions. 
 
〔16〕  MX-FR11/FR11U 
 
1. Unpacking 
 
A. Check the packed items 
 
1) Check that all the items are included in the package 
 
 
 
 
 
 
 
 
No. 
Packed part names 
Quantity
 
 
 
MFP_PRG1 ROM 
 
 
 
MFP_PRG2 ROM 
 
 
 
Operation manual 
 
 
 
Caution sheet (MX-FR11only) 
 
 
 
USB memory 
 
 
 
Certificate label 
(MX-FR11only) 
 
 
2. Installation 
<Note before installation> 
* To enable the data security function, the product key 
must be acquired (For the method of acquiring the 
product key, contact the dealer.) 
* Before installing the data security kit, be sure to 
perform backup of data stored in the memory 
(including HDD) of the main unit. When the data 
security kit is installed, all the job data stored in the 
memory (including HDD) of the main unit will be lost. 
* If the LINE indicator or the DATA indicator for the 
printer and image transmission on the operation panel 
is lit or blinking, data that has not been processed 
remains in the memory of the main unit (including 
HDD). Output or transmit all the data to clear the data 
remaining in the main unit and then start installation. 
(Check to insure that neither the LINE indicator nor the 
DATA indicator on the operation panel does light up or 
blink.) 
 
A. Turn off the power switch of the main unit. 
 
1) Turn the power switch located on the operation 
panel to the 
“OFF” position. 
 
 
 
 
2) After checking that the operation panel has gone 
out, open the front cabinet and turn the main power 
switch to the 
“OFF” position. 
 
 
 
 
3) Remove the power plug of the main unit from the 
outlet. 
 
 
 
 
B. Pull out the control PWB. 
 
・ If cables are connected to the control PWB unit, 
remove all cables. 
1) Push the location indicator in the illustration to 
unlock, and remove the ozone filter cover from the 
right rear cabinet. 
 
 
 
2) Remove the screw from the right rear cabinet. 
3) Remove the right rear cabinet. 
4) Remove the two screws from the control PWB unit. 
・If the fax box unit is installed, carry out steps 5),6) 
and 7) additionally. 
5) Pull out the control PWB unit and remove the snap 
band. 
6) Remove the interface cable from the frame. 
7) Remove the connector. 
8) Pull out and remove the control PWB unit. 
 
 
 
1/4
 
Common Criteria 
Validated 
MFP Data Security Kit 
 
C. Mount the data security kit ROMs to the control 
PWB unit. 
 
  Remove the ROMs PROG1/PROG2)from the control 
PWB and replace them with data security kit ROMs
(MFP_PRG1 /MFP_PRG2) 
  When mounting the data security kit ROMs, insert 
them to the same positions in the same orientations 
as those before replacement until they click and 
ensure that the inserted ROMs are locked with the 
sockets. 
 
 
 
 
 
 
D. Reattach the control PWB and the right rear 
cabinet. 
 
・ If the fax box unit is installed, carry out steps 1),2) 
and 3) additionally. 
1) Connect the interface cable to the control PWB unit.
2) Push the interface cable into the recessed portion of 
the sheet metal on the control PWB unit. 
3) Attach the snap band to the sheet metal of the 
control PWB unit. 
 
 
 
 
 
4) Push the control PWB unit into the main unit. 
5) Secure the unit with the two screws. 
 
 
 
 
・If the fax box unit is installed, carry out step 6) 
additionally. 
6) Fit the interface cable into the right rear cabinet 
cover. 
7) Attach the right rear cabinet cover to the main unit. 
At this time, check that the four hooks are properly 
fitted to the main unit. 
8) Secure the right rear cabinet with the screw 
 
 
 
9) Attach the ozone filter cover to the main unit. 
 
 
 
・ Reconnect the cables that have been removed in 
step B to the original positions of the control PWB 
unit. 
 
 
E. Turn on the main power switch of the main unit. 
 
1) Insert the power plug of the main unit to the outlet. 
 
 
 
2/4
 
2) Turn on the main power switch 
 
 
 
 
3) Turn on the power switch located on the operation 
panel. 
 
 
 
 
 
 
F. Installation of the DSK firmware 
 
(1) MFP booting operations after replacement 
 
1) Turn ON the power, and the main program error is 
displayed 
 
Main Program Error!! 
 
 
2) After 10 seconds from displaying the above error, the 
following display is made. 
 
Emergency Prog Init 
Please wait 
 
3) The main program version is displayed, and the 
machine enters the boot mode. 
 
Version Check 
conf: xxxxxxxx 
 
 
(2) Boot Mode operation 
 
Install the DSK firmware as follows. 
 
a.  Operations and functions of the keys in the boot mode 
 
 
 
Normal key name 
Boot mode key 
name 
Function 
Start key 
(monochrome) 
[OK] key 
Executes the selected 
function or item 
Home key 
[MENU] key 
Selects a menu 
Job Status key 
[UP] key 
Selects an item 
System setting key 
[DOWN] key 
Selects an item 
 
b.  Function selection in the Boot Mode 
 
The functions of the boot mode can be selected by 
pressing MENU key as shown in the figure below. 
 
 
 
 
Version Check 
conf: xxxxxxxx 
 
 
 
 
 
 
 
 
 
MENU key   
 
 
MENU key  
 
 
 
 
 
 
Firm Update 
  From USB Memory 
 
 
(3) DSK Firmware installing procedures in the boot mode 
 
1) Boot the machine in the boot mode. With 
“Version 
Check
” displayed. Press [MENU] key. and the machine 
enters the firmware update mode. (
“Firm Update” is 
displayed) 
 
 
Firm Update 
  From USB Memory 
 
2) Insert the USB memory with the installation or update 
firmware file (SFU file) in it into the USB port of the 
machine, and press [OK] key 
 
Firm Update 
> xxxxxxxx.sfu 
 
 
3) Select the target firmware file SFU file)by using 
[UP] key and [DOWN] key 
・When [OK] key is pressed with the directory name 
displayed, the control can enter the lower level 
directory (However, one level lower only) 
 
4) Press [OK] key. 
The selected firmware file SFU file)  is read. (It takes 
about one minutes) 
 
Firm Update 
 Reading Data 
 
 
3/4
Page of 5
Display

Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Service Manual ↓ Size: 341.39 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Copying Equipment. Information contained in Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man131) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.