5. Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys,
navigate and select the required firmware SFU.
Note:
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or
the [BACK] key to return to the parent folder(s).
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or
the [BACK] key to return to the parent folder(s).
6. Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file.
After reading is completed, the firmware update (writing) will commence automatically.
Note:
The abbreviated name/location of the firmware that is being updated will appear in the upper
right corner.
The abbreviated name/location of the firmware that is being updated will appear in the upper
right corner.
7. If the firmware upgrade completes successfully, RESULT OK will be displayed:-
Result: NG = Update failed; Result: Not Update = Update is not executed.
8. Power off the MFP and return the SCN-MFP CONTROL PWB UPDATE DIP-SW to OFF (Default):-
9. Power ON the MFP, and confirm that the machine boots up normally.
10. Power OFF the MFP and refit the MFP PWB Rear Cabinet & Screws.
11. Check/confirm the firmware version using SIM 22-05.
CN UPDATE - Firmware Recovery Procedure is now complete.
Firm Update
> 0200K100.sfu
> 0200K100.sfu
Firm Update
Reading Data
Reading Data
Firm Update IcuM
Writing Data
Writing Data
Firm Update IcuM
Result : OK
Result : OK
Firm Update
From USB Memory
From USB Memory
E-MANUAL UPDATE
SHARP
42
1. Using a PC, copy the E-Manual Update file onto the root of a USB memory device (as shown).
Note: The E-Manual firmware for MX-3050N-MX-6050N series consists of 1 file (*.UAR).
2. Insert the USB memory device containing the E-Manual firmware file into the main USB Port and
enter Simulation 49-03 [E-MANUAL UPDATE].
Note:
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-03
E-Manual Update. In addition, if no USB device is detected, an error message will be displayed.
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-03
E-Manual Update. In addition, if no USB device is detected, an error message will be displayed.
3. Browse and select the E-manual update file – example shown = Manual_0130K100.uar:-
4.
The current and updated version should then be displayed. Press Execute to commence the E-manual
upgrade.
upgrade.
SHARP
E-MANUAL UPDATE
43
Update File Checking and a progress of the E-manual update will be displayed:-
5. Once the update is complete, press OK to exit simulation mode:-
E-Manual update is complete.
WATERMARK UPDATE
SHARP
44
1. Using a PC, copy the Watermark Update firmware onto the root of a USB memory device:-
Caution:
When copying the Watermark firmware/directories onto the USB drive, do not change the folder
hierarchy or files.
hierarchy or files.
2. Insert the USB memory device containing the Watermark firmware into the main USB Port and enter
Simulation 49-05 [Water mark update].
Note:
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-05
Water mark update. In addition, if no USB device is detected, an error message will be displayed.
Note:
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-05
Water mark update. In addition, if no USB device is detected, an error message will be displayed.
3. Browse and select the Directory containing the Watermark update files.
Example shown = WM_02000000:-
4. The current and updated version should now be displayed. Press Execute to commence upgrade:-