FIRMWARE RECOVERY
 
 
41
 
5.  Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys, 
navigate and select the required firmware SFU. 
 
 
 
 
Note: 
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or  
the [BACK] key to return to the parent folder(s). 
 
6.  Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file. 
After reading is completed, the firmware update (writing) will commence automatically. 
 
 
 
 
 
Note:   
The abbreviated name/location of the firmware that is being updated will appear in the upper  
right corner. 
 
7.  If the firmware upgrade completes successfully, RESULT OK will be displayed:- 
 
 
 
 
Result: NG = Update failed;    Result: Not Update = Update is not executed. 
 
8.  Power off the MFP and return the SCN-MFP CONTROL PWB UPDATE DIP-SW to OFF (Default):- 
 
 
 
9.  Power ON the MFP, and confirm that the machine boots up normally. 
 
10. Power OFF the MFP and refit the MFP PWB Rear Cabinet & Screws. 
 
11. Check/confirm the firmware version using SIM 22-05. 
 
CN UPDATE - Firmware Recovery Procedure is now complete. 
 
 
 
Firm Update 
> 0200K100.sfu
 
Firm Update 
    Reading Data
 
Firm Update              IcuM 
    Writing Data
 
Firm Update           IcuM 
    Result  :  OK
 
Firm Update 
    From USB Memory
 
E-MANUAL UPDATE 
SHARP  
 
42
 
1.  Using a PC, copy the E-Manual Update file onto the root of a USB memory device (as shown). 
 
Note: The E-Manual firmware for MX-3050N-MX-6050N series consists of 1 file (*.UAR). 
 
 
 
2.  Insert the USB memory device containing the E-Manual firmware file into the main USB Port and 
enter Simulation 49-03 [E-MANUAL UPDATE]. 
Note: 
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-03  
E-Manual Update. In addition, if no USB device is detected, an error message will be displayed. 
 
 
 
 
 
 
 
 
 
 
 
3.  Browse and select the E-manual update file – example shown = Manual_0130K100.uar:- 
 
 
 
4. 
The current and updated version should then be displayed. Press Execute to commence the E-manual 
upgrade.
 
 
SHARP
 
E-MANUAL UPDATE
 
 
43
 
 
 
Update File Checking and a progress of the E-manual update will be displayed:- 
 
 
 
5.  Once the update is complete, press OK to exit simulation mode:- 
 
 
 
E-Manual update is complete. 
WATERMARK UPDATE 
SHARP  
 
44
 
1.  Using a PC, copy the Watermark Update firmware onto the root of a USB memory device:- 
 
Caution:  
When copying the Watermark firmware/directories onto the USB drive, do not change the folder 
hierarchy or files. 
 
 
 
2.  Insert the USB memory device containing the Watermark firmware into the main USB Port and enter 
Simulation 49-05 [Water mark update]. 
Note: 
When using Easy Mode, select Version Upgrade from the Installation tab and execute SIM49-05 
Water mark update. In addition, if no USB device is detected, an error message will be displayed. 
 
 
 
 
 
 
 
 
 
 
 
3.  Browse and select the Directory containing the Watermark update files. 
Example shown = WM_02000000:- 
 
 
 
4.  The current and updated version should now be displayed. Press Execute to commence upgrade:- 
 