MAINTENANCE 
SHARP  
 
16
 
Maintenance Indications: 
 
DK 
Black Drum Counter has reached the specified life. 
Replace Black Drum 
PROCESS
 UNI
 
 
DC 
Cyan Drum Counter has reached the specified life. 
Replace Cyan Drum 
 
 
DM 
Magenta Drum Counter has reached the specified life. 
Replace Cyan Drum 
 
 
DY 
Yellow Drum Counter has reached the specified life. 
Replace Cyan Drum  
 
 
MCK
 
Black Main Charge Counter has reached the specified life. 
Replace K Main Charge Kit 
 
 
MCC
 
Cyan Main Charge Counter has reached the specified life. 
Replace C Main Charge Kit 
 
 
MCM
 
Magenta Main Charge Counter has reached the specified life. 
Replace M Main Charge Kit 
 
 
MCY
 
Yellow Main Charge Counter has reached the specified life. 
Replace Y Main Charge Kit 
 
 
VK 
Black Developer Counter has reached the specified life. 
Replace Black Developer
 
 
 
VC 
Cyan Developer Counter has reached the specified life. 
Replace Colour Developer Kit 
(CMY)
 
 
VM 
Magenta Developer Counter has reached the specified life. 
 
VY 
Yellow Developer Counter has reached the specified life. 
 
FK1 
Fusing Belt Print Counter has reached the specified limit. 
Replace the Fusing Belt Kit
 
FUSER
 
 
 
FK2 
Pressure Roller Print Counter has reached the specified limit. 
Replace the Pressure Roller Kit
 
 
TK1
 
Primary Transfer Unit Counter has reached the specified limit. 
Replace the Primary Transfer 
Belt & Blade Kits
 
TRANSFE
R
 
 
 
TK2
 
Secondary Transfer Unit Counter has reached the specified limit. 
Replace the Secondary 
Transfer Roller Kit
 
 
 
TK3
 
PTC Unit Counter has reached the specified limit. 
Replace the PTC Unit
 
 
TA 
Maintenance [All] Counter has reached specified limit
 
 
CA 
Maintenance [Colour] Counter has reached specified limit
 
 
AA 
Maintenance [All] & [Colour] Counters have reached the specified limits
 
 
Starting Powder: 
 
The following starting powder should be applied to the relevant consumable item during maintenance:- 
 
Starting Powder 
OPC Drum 
Primary Transfer Belt 
MX-3050N – MX-6050N 
UKOG-0312FCZZ 
[Stearic Acid] 
CKOG-0345DS51 
[Yellow Toner] 
 
 
SHARP
 
MAINTENANCE
 
 
17
 
MX-30
5
0N 
MX-3550N
 
MX-4050N 
MX-5050N 
MX-6050N 
PROCESS SECTION – COLOUR: 
(Colour maintenance counter has reached the specified life). 
Every 
150K 
Every 
300K 
Every 
200K 
Every 
400K 
Every 
200K 
Every 
400K 
 
 
 
 
 
 
 
 
 
 
 
 
 
Replace Cyan, Magenta & Yellow OPC Drum: (MX-60GRSA x 3)  
 
 
 
 
 
 
Replace Cyan, Magenta & Yellow Main Charge Kits:- 
 
 
 
 
x
 
x
 
  Main Charge Unit & Cleaning Blade (MX-407MK x 3) 
x
 
x
 
x
 
x
 
 
 
  Main Charge Unit & Cleaning Blade (MX-607MK x 3) 
 
x 
 
x 
 
Replace C, M, Y Developer (MX-60GVSA). 
x
 
x
 
x
 
x
 
 
 
Replace C, M, Y DV toner filter kit (MX-607FK x 3). 
 
 
 
 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
 
 
 
 
Sim 24-04  
Clear Drum CTRG C, M, Y (Colour) Counters. 
 
 
 
 
 
 
 
 
Clear Main Charger C, M, Y (Colour) Counters. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
 
 
 
 
Clear Drum Blade C, M, Y (Colour) Counters. 
 
 
 
 
 
 
 
 
Clear Maintenance [Colour] Counter. 
 
 
 
 
 
 
Sim 24-05  
Clear Developer C, M, Y (Colour) Counters. 
 
x
 
 
x
 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
x 
 
x 
 
Sim 25-02  
Toner Concentration Adjustment - Select C, M, Y. 
 
 
 
 
 
 
Note:   
If ALL developer is replaced at the same time, select 
CMYK. When Sim 25-02 is executed, the Developer 
Counter (Sim 24-05) is also cleared automatically. 
 
x 
 
x 
 
Sim 44-27  
Clear Half Tone Process Correction. 
 
 
 
 
 
Every 
200K 
Every 
400K 
Every 
250K 
Every 
500K 
Every 
250K 
Every 
500K 
PROCESS SECTION -MONOCHROME: 
(Total / K maintenance counter has reached the specified life). 
 
 
 
 
 
 
 
 
 
 
 
 
 
Replace Black OPC Drum (MX-60GRSA). 
 
 
 
 
 
 
Replace Black Main Charge Kit:- 
 
 
 
 
x
 
x
 
  Main Charge Unit & Cleaning Blade (MX-407MK) 
x
 
x
 
x
 
x
 
 
 
 
Main Charge Unit & Cleaning Blade (MX-607MK) 
 
 
 
Replace Black Developer  (MX-60GVBA). 
x
 
x
 
x
 
x
 
 
 
Replace Black DV toner filter kit (MX-607FK). 
 
 
 
 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
 
 
 
 
Sim 24-04  
Clear Drum CTRG K (Black) Counter. 
 
 
 
 
 
 
 
 
Clear Main Charger K (Black) Counter. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
 
 
 
 
Clear Drum Blade K (Black) Counter. 
 
 
 
 
 
 
 
 
Clear Maintenance [ALL] Counter. 
 
 
 
Sim 24-05  
Clear Developer K (Black) Counter. 
 
x
 
 
x
 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
 
 
Sim 25-02  
Toner Concentration Auto Adjustment - Select K. 
 
 
 
 
 
 
Note:   
If ALL developer is replaced at the same time, select 
CMYK. When Sim 25-02 is executed, the Developer 
Counter (Sim 24-05) is also cleared automatically. 
 
 
MAINTENANCE 
SHARP  
 
18
 
MX-3050N 
MX-3550N
 
MX-4050N 
MX-5050N 
MX-6050N
 
IMAGE QUALITY ADJUSTMENTS  
(After Replacement Described Above): 
 
 
 
 
 
 
 
 
 
Sim 44-02 
Image Density & Registration Sensor Adjustment. 
 
 
 
Sim 44-06 
Process Control execution. 
 
 
 
Sim 44-26 
Half tone process control execution. 
 
 
 
Sim 50-22 
Drum Position & Registration Adjustment - select ALL. 
 
 
 
Sim 61-13 
Clear laser F/R density correction data. 
 
 
 
Sim 61-11 
Laser F/R density variation correction execution. 
 
 
 
Sim 46-74  
Automatic Colour Balance Adjustment (Copy & Printer). 
 
 
 
Sim 46-01  
Adjust Copy Exposure Density (Colour). 
 
 
 
Sim 46-02 
Adjust Copy Exposure Density (B/W).  
 
 
 
 
 
 
 
SCANNER SECTION: 
 
 
 
Clean Platen Glass, Mirrors, CCD, and white reference plate. 
 
 
 
Clean RSPF Scanning Glass. 
 
 
 
 
 
 
 
PAPER FEED & TRANSPORT SECTION: 
 
 
 
Check/Clean ALL Paper Path Sensors (including Duplex unit). 
 
 
 
Check/Clean ALL PF Transport Rollers. 
 
 
 
Check/Clean ALL TRAY PF Rollers (check tray counter using Sim 22-09) 
replace every 100k (individual tray) or after 1 year. 
 
 
 
Sim 24-02  
Clear Individual Tray Counter (only after PF roller  
 
 
replacement) 
 
 
 
 
 
 
 
RSPF: 
 
 
 
Check/Clean SPF Pick-Up, Paper Feed & Separation Rollers (check SPF 
counter using Sim 22-08) – replace every 100k or after 1 year. 
 
 
 
Check/Clean SPF Paper Feed Torque Limiter – replace every 800k. 
 
 
 
Check/Clean ALL Transport Rollers. 
 
 
 
Check/Clean Second Scan Section Scanning Glass. 
 
 
 
Check/Clean Lamp Section & Reflector. 
 
 
 
 
MX-3050N
 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N
 
 
Every 
250K 
Every 
300K 
Every 
300K 
PROCESS SECTION: 
In addition to Total / K schedule (or colour schedule if indicated):-
 
 
 
 
 
 
 
 
Replace PTC unit:-
 
 
 
x
 
  PTC unit (MX-607CU) 
 
 
 
  PTC unit (MX-608CU) 
Note: MX-607CU cannot be used on MX-5050N/6050N series
 
 
 
 
Check Waste Toner Container (MX-607HB) & Replace LSU Cleaning 
Base. 
 
 
 
Sim 24-04  
Clear PTC Counters. 
 
 
 
SHARP
 
MAINTENANCE
 
 
19
 
MX-3050N
 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N
 
 
Every 
250K 
Every 
300K 
Every 
300K 
FUSING SECTION: 
 
 
 
 
 
 
 
Replace Fusing Belt unit:-
 
 
 
x
 
  Fusing Belt Unit (MX-607FB). 
 
  Fusing Belt Unit (MX-608FB). 
Note: MX-607FB cannot be used on MX-5050N/6050N series
 
 
 
 
Replace Pressure Roller Kit  (MX-607LH):- 
 
Pressure Roller 
 
 
 
Apply UKOG-0235FCZZ grease to the shaft section of the Pressure 
Roller. 
 
 
 
Check/Clean both Upper and Lower Thermistors. 
 
 
 
Sim 24-04  
Clear Fusing Belt Counters. 
 
 
 
 
 
Clear Fusing Roller Counters. 
 
 
 
 
 
Clear Press Roller Counters. 
 
 
 
 
 
Clear Separation Pawl Counters. 
 
 
 
 
 
Clear Separation Plate Counters. 
 
 
 
 
 
Clear Fusing Unit Counter. 
 
 
 
 
 
 
 
TRANSFER SECTION: 
 
 
 
Replace Primary (Image) Transfer Belt Kit  (MX-607B1):- 
 
Primary Transfer Belt
 
 
 
 
Replace Primary Transfer Cleaning Blade Kit  (MX-607TL):- 
  Primary Transfer Blade. 
  Cleaning Roller
 
 
 
 
Apply Yellow Toner [CKOG-0345DS51] to Primary Transfer Belt 
 
 
 
Replace Secondary Transfer Roller Kit  (MX-607B2):- 
 
Secondary Transfer Roller Unit. 
 
 
 
Clean ID & Registration Sensors.
 
 
 
 
Sim 24-04  
Clear TC1 Belt Counters. 
 
 
 
 
 
Clear Trans Blade Counters. 
 
 
 
 
 
Clear TC1 Belt Unit Counter. 
 
 
 
 
 
Clear TC2 Roller Counters. 
 
 
 
 
 
Clear TC2 Roller Unit Counter. 
 
 
 
Sim 50-22 
Drum Position & Registration Adjustment - select ALL. 
 
 
 
 
Every 
300K 
Every 
300K 
Every 
300K 
FILTER SECTION: 
 
 
 
 
 
 
 
Replace Ozone Filter Kit  (MX-607FL):- 
 
Ozone Filter 
 
 
 
Sim 24-04  
Clear Ozone Filter Counter. 
 
 
 
 
Page of 82
Display

Click on the first or last page to see other MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N service manuals if exist.