DOWNLOAD Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Service Manual ↓ Size: 297.67 KB | Pages: 9 in PDF or view online for FREE

Model
MX-3050N MX-3060N MX-3070N MX-3550N MX-3560N MX-3570N MX-4050N MX-4060N MX-4070N (serv.man98)
Pages
9
Size
297.67 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / CCE 1764R Rom Upgrade 9 10 additional info.
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Service Manual / Technical Bulletin ▷ View online

 
 
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM, E-Manual  ・・・(9)   
From May 2017 production 
Model 
Desti- 
nation 
ROM 
control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
E-Manual 
MX-3050N 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N 
Except 
for 
Taiwan, 
South 
Africa
 
F00 
0600K100_ 
17041700 
0600K100  0600Z100  0600Z100  0500Z100 
0240K100 
MX-3060N 
MX-3560N 
MX-4060N 
0600Z100_ 
17041700 
0600Z100  0600Z100  0600Z100  0500Z100 
0240Z100 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5070N 
MX-6070N 
0500Z100 
  Item of change  :See the separate page
 
 
 
 
 
 
ROM Version Combination History Table 
Model : MX-3050N/3550N/4050N/5050N/6050N 
No. 
Destination 
ROM 
Control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
FAX
 
E-Manual 
Action 
T/R No 
(8) 
ALL 
E03 
0513K100_ 
16122000 
0512K100 
0510Z100 
0501Z100 
0400Z100 
0230K100 
2017/1 
Mid 
CCE-1697 
(7) 
E02 
0512K100_ 
16112900 
0511K100 
0510Z100 
0501Z100 
0400Z100 
0230K100 
2016/12 
Mid 
CCE-1685 
(6) 
E01 
0511K100_ 
16111601 
0511K100 
0510Z100 
0500Z100 
0400Z100 
0230K100 
2016/11 
Mid 
CCE-
1666R 
(5) 
E00 
0510K100_ 
16110700 
0510K100 
0510Z100 
0500Z100 
0400Z100 
0230K100 
(3) 
D00 
0400K100_ 
16061400 
0101Z100 
0400Z100 
0400Z100 
0300Z100 
0220K100 
2016/6 
CCE-1605 
(2) 
North 
America 
B01 
0201K100_ 
16011400 
0201Z100 
0200Z100 
0200Z100 
0201K100 
0100Z100 
0130K100 
2016/2 
Mid 
CCE-1515 
Except for 
North 
America 
A01 
(1) 
ALL 
B00 
0200Z100_ 
15121800 
0200K100 
0200Z100 
0200Z100 
0200Z100 
0100Z100 
0130K100 
2015/12 
Mid 
CCE-1507 
 
Model : MX-3060N/3560N/4060N 
No. 
ROM 
Control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
E-Manual 
Action 
T/R No 
(8) 
E03 
0513Z100_ 
16122000 
0512Z100 
0510Z100 
0501Z100 
0400Z100 
0230Z100 
2017/1 
Mid 
CCE-1697 
(7) 
E02 
0512Z100_ 
16112900 
0511Z100 
0510Z100 
0501Z100 
0400Z100 
0230Z100 
2016/12 
Mid 
CCE-1685 
(6) 
E01 
0511Z100_ 
16111601 
0511Z100 
0510Z100 
0500Z100 
0400Z100 
0230Z100 
2016/11 
Mid 
CCE-
1666R 
(5) 
E00 
0510Z100_ 
16110700 
0510Z100 
0510Z100 
0500Z100 
0400Z100 
0230Z100 
(3) 
D00 
0400Z100_ 
16061400 
0101Z100 
0400Z100 
0400Z100 
0300Z100 
0300Z100 
0220Z100 
2016/6 
CCE-1605 
(2) 
B01 
0201Z100_ 
16011400 
0201Z100 
0201Z100 
0200Z100 
0200Z100 
0100Z10a 
0150Z100 
2016/2 
Mid 
CCE-1515 
(1) 
B00 
0200Z100_ 
15121800 
0200Z100 
0200Z100 
0200Z100 
0100Z10a 
0101Z100 
0150Z100 
2015/12 
Mid 
CCE-1507 
 
Model : MX-3070N/3570N/4070N/5070N/6070N 
No. 
ROM 
Control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
E-Manual 
Action 
T/R No 
(8) 
E03 
0513Z100_ 
16122000 
0512Z100 
0510Z100 
0501Z100 
0400Z100 
0400Z100 
0230Z100 
2017/1 
Mid 
CCE-1697 
(7) 
E02 
0512Z100_ 
16112900 
0511Z100 
0510Z100 
0501Z100 
0400Z100 
0400Z100 
0230Z100 
2016/12 
Mid 
CCE-1685 
(6) 
E01 
0511Z100_ 
16111601 
0511Z100 
0510Z100 
0500Z100 
0400Z100 
0400Z100 
0230Z100 
2016/11 
Mid 
CCE-
1666R 
(5) 
E00 
0510Z100_ 
16110700 
0510Z100 
0510Z100 
0500Z100 
0400Z100 
0400Z100 
0230Z100 
(4) 
D01 
0401Z100_ 
16080400 
0401Z100 
0400Z100 
0401Z100 
0300Z100 
0300Z100 
0220Z100 
2016/8 
Mid 
CCE-
1634R2 
(3) 
D00 
0400Z100_ 
16061400 
0101Z100 
0400Z100 
0400Z100 
0300Z100 
0300Z100 
0220Z100 
2016/6 
CCE-1605 
(2) 
B01 
0201Z100_ 
16011400 
0201Z100 
0201Z100 
0200Z100 
0200Z100 
0100Z10a 
0150Z100 
2016/2 
Mid 
CCE-1515 
(1) 
B00 
0200Z100_ 
15121800 
0200Z100 
0200Z100 
0200Z100 
0100Z10a 
0101Z100 
0150Z100 
2015/12 
Mid 
CCE-1507 
 
【Description】 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Implementation of following features to erase cache information on 
authentication for cloud connection in User Control -> User List 
 
- Delete Your Information for External Connect 
- Delete All Information for External Connect 
 
 
 
 
Main unit 
control 
Addition of a mode which shows toner quantity in MIB until it turns “Empty” 
using values while toner quantity is “Low” 
SIM26-69 H (MIB TONER LOW INDIXATION) 
0: Retrieves information on toner quantity with value (Default) 
1. Retrieves “Low” status (-3) 
* “Toner Low” is not indicated with default condition. 
 
 
 
 
Main unit 
control 
Implementation of a Soft SW which turns on/off the confirmation message 
displayed when Blank Page Skip feature is enabled. 
SIM55-3 SW No.44   
Data 2 (Copy) 
Data 3 (Image Send) 
0: Display (Default) 
1: Do not display 
 
 
 
 
Main unit 
control 
Implementation of an error lamp setting in Device Settings with selections of 
“Not Use”, “Blink Only” and “Light & Blink” 
 
 
 
 
Main unit 
control 
Implementation of selection whether to execute auto registration of user 
information in “User Control” -> “Default Settings” on main unit 
 
 
 
 
Main unit 
control 
Changing authentication setting for home directory during user registration 
from “Use Login Name And Password for User Authentication” to “Use Login 
Name for User Authentication” 
 
 
 
 
Main unit 
control 
Modification of behavior during Toner near end status as follows: 
- The alert on toner low is notified via E-RIC when an e-mail address is 
entered or “Toner Low” is selected on management web page. This won’t be 
affected whether SIM26-69 is set to A or C.   
SIM26-69 (Operating condition during toner near end) 
A: Whether to display a message to prompt preparation of toner 
C: Whether to display a message to notify toner near end 
 
 
 
 
Main unit 
control 
Correction of problem with touch panel which does not work in low 
temperature environment 
 
 
 
 
Main unit 
control 
Correction of failure to reboot MFP after firmware update 
 
 
 
 
10 
Main unit 
control 
Collecting all log data in one folder in thumb drive when SIM56-99 (batch log 
data collection) is executed. 
 
 
 
 
11 
Main unit 
control 
Correction of machine lockup which may occur when authentication using 
an IC card is executed while primarily requesting the authentication to an 
authentication server 
 
 
 
 
12 
Main unit 
control 
Correction of machine lockup which occurs while searching an address in 
the Address Book 
 
 
 
 
13 
Main unit 
control 
Correction of failure with keyboard 
The operating “CAPS” key on software keyboard turns on the Num Lock on 
external keyboard being connected, illuminating the LED. 
 
 
 
 
14 
Main unit 
control 
Correction of recording unnecessary logs in Active Directory environment 
 
 
 
 
15 
Main unit 
control 
Correction of MPF reboot after execution of User Control -> User Count -> 
Save User Count -> Print and Delete the Data 
 
 
 
 
○=applied 
 
【Description】 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
16 
Main unit 
control 
Correction of fuser motor keeps running with low speed after opening Right 
cover 
 
 
 
 
17 
Main unit 
control 
Modification of software control to prevent H3 trouble due to overshoot. 
 
 
 
 
18 
Main unit 
control 
Correction of F1-00 error (Communication error between Finisher and PCU 
PWB) 
This error may occur when a staple job is immediately followed by a non-
staple job. 
 
 
 
 
19 
Main unit 
control 
Modification of failure to clinch staple properly 
 
 
 
 
20 
Main unit 
control 
Fusing belt unit for MX-5050N/5070N/6050N/6070N series was 
changed from May 2017 production.    For the purpose to avoid the 
low temperature offset, the fusing temperature control function has 
been added to Soft SW and the default value has been changed. 
For machines before May 2017 production, the modification has 
been made so that the set value does not automatically change 
even when updating the firmware to this version.     
If the set value is manually changed from 0 to 1, the high 
temperature offset may occur. 
In addition, if the setting of Soft SW is changed from 0 to 1 while the 
fusing belt unit before May 2017 production is installed, the high 
temperature offset may occur. 
*Changed fusing unit is supplied as the service parts.    This will be 
announced on Service Information later. 
 
SIM55-1 SW No.22 Data 8 
MX-5150FN/6150FN/5170FN/6170FN series 
0: Not control the temperature 
1: Control the temperature (Default) 
    
MX-
3050N/3550N/4050N/3060N/3560N/4060N/3070N/3570N/4070N 
series 
0: Not control the temperature   
1: Not control the temperature (Default) 
 
*On MX-3050N/3060N/3070N series, both 0 and 1 are set to “Not 
control the temperature” because Fusing belt unit has not been 
changed.
 
NA 
NA 
 
 
21  Image Quality 
Implementation of a Soft SW which interrupts a job to provide lubricant. 
The purpose of implementing this Soft SW is to modify black streaks due to 
defective Transfer cleaning. 
Sim55-1 SW12-5 
0: No interruption during a job (Default) 
1: The job is interrupted for application of lubricant 
 
 
 
 
22  Image Quality 
Correction of failure to execute auto registration adjustment after replacing 
toner cartridge 
The registration adjustment will not be executed unless it is executed 
manually or by turning off and on the power. 
 
 
 
 
 
 
○=applied 
Page of 9
Display

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Service Manual ↓ Size: 297.67 KB | Pages: 9 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Copying Equipment. Information contained in Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man98) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.