DOWNLOAD Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Service Manual ↓ Size: 365.34 KB | Pages: 10 in PDF or view online for FREE

Model
MX-3050N MX-3060N MX-3070N MX-3550N MX-3560N MX-3570N MX-4050N MX-4060N MX-4070N (serv.man77)
Pages
10
Size
365.34 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / CCE 1800 Rom Upgrade (1 2) for DSK ONLY MX-FR51U MX-FR52U Bulletin only
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Service Manual / Technical Bulletin ▷ View online

 
【Description】・・・(2) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Correction of the problem that FAN may continue rotating in Power Save 
Mode 
 
 
 
 
Main unit 
control 
Correction of the problem that the auto adjustment of fusing temperature 
is frequently caused when repeatedly performing the copies in 
color/B&W with the different sizes such as A3, B4, etc. 
 
The function not to display “Automatically adjusted” message of the 
fusing temperature has been added to Soft SW in order to enable the 
operation to read the next original during auto adjustment. 
Sim55-1 SW22-1 
0: Display (Default) 
1: Not display 
 
 
 
 
Main unit 
control 
Since there are some cases where H3 trouble has been detected in the 
region of CE Mark being applied.    Modification has been made to 
improve the trouble detection. 
 
 
 
 
 
 
Upgrade of ICU, ASIC, PCU, SCU and SPF-ROM
  ・・・(1) 
From Augsut 2017 production 
Model 
ROM 
control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
MX-LC17 
MX-FR51U 
B00 
0650Kc00_ 
17062300 
0650K100  0650Zc00  0650Z100  0500Z100 
0200Z100 
MX-FR52U 
0650Zc00 _ 
17062300 
0650Z100  0650Zc00  0650Z100  0500Z100  0500Z100 
  Item of change  :See the separate page 
 
 
 
○=applied 
 
 
【Description】・・・(1) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Implementation of Soft SW to print A5 size paper as A5R from Bypass tray. 
When this SW is enabled, the A5 size image output from Bypass tray is automatically 
output as A5R size. 
 
SIM55-3 SW39 Data 5 
0: Disabled (Default) 
1: Enabled 
 
*Following setting has to be turned ON to enable this feature: 
System Settings > Printer Settings > Condition settings > Enable Detected Paper Size 
in Bypass Tray: ON 
 
 
 
 
Main unit 
control 
Correction of operational failure: Following problem occurred when the MFP was used 
25 five days in a row (without turning off the power) 
- A message which indicates machine is not available for usage appeared. 
- The LCD turned dark. 
 
 
 
 
Main unit 
control 
Correction of slowing down the transmission speed after sending multiple jobs 
 
 
 
 
4
 
Main unit 
control 
Eliminating load on SSD 
The log data are written many times under the environment where the MFP switches 
to power save mode and recover from power save mode frequently. The transition time 
from 1W power save mode -> silent recovery -> power save mode has been changed 
from “1 min.” to “15 min.” to decrease the writing of log data to reduce load on SSD. 
 
 
 
 
5
 
Main unit 
control 
Correction of failure to change the current status of Machine Identification from “Input 
Tray Empty” 
 
 
 
 
6
 
Main unit 
control 
Correction of failure to recover from power save mode 
 
 
 
 
7
 
Main unit 
control 
Correction of failure to reflect the name of the registered paper type in the Tray 
Settings 
 
 
 
 
8
 
Main unit 
control 
Correction of failure to execute “Save User Count” 
 
 
 
 
9
 
Main unit 
control 
Correction of failure which tapping of “Contacts/Group Address” icon on Home screen 
rejected, displaying an error message “This function cannot be selected.”. 
 
 
 
 
10
 
Main unit 
control 
Correction of E7-03 error or failure to start-up MFP 
 
 
 
 
11
 
Main unit 
control 
Correction of high temperature offset on B4/B5 size paper with Plain Paper Weight 
Setting 80 g/m² - 150g g/m² 
 
Plain Paper Weight Settings 
System Settings > Common Settings > Device Control 
NA 
NA 
○ 
○ 
12
 
Main unit 
control 
Correction of L4-17~20   
The error due to toner waste buildup caused by the failure to detect waste toner box 
full has been fixed. 
 
 
 
 
13
 
Main unit 
control 
Change of heater lamp control 
This is to adjust to the fluorescent which flickers during fluctuation of voltage. 
 
 
 
 
14
 
Main unit 
control 
Remedy of overtoning and toner dispersion due to replenishment of excess amount of 
toner 
 
 
 
 
15
 
Main unit 
control 
Correction of C1-01/03/05/07 trouble during MC cleaning under HH environment 
NA 
NA 
○ 
○ 
 
 
○=applied 
 
 
 
【Description】・・・(1) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
16
 
Main unit 
control 
Correction of false detection of F2-22 (Discharge lamp trouble (K)) 
The trouble may occur while the job in monochrome mode (which tends to trigger the 
execution of process control for BK) is mainly running. 
NA 
NA 
 
 
17
 
Main unit 
control 
Correction of F2-65 trouble 
This trouble may occur if the MFP is runs out of toner during continuous run, failing to 
replenish the toner properly. 
NA 
NA 
○ 
○ 
18
 
Main unit 
control 
Correction of failure to recognize original 
The problem may occur if an OC cover is opened and closed too quickly after placing 
an original on the table, failing to detect original size. 
 
 
 
 
19
 
Main unit 
control 
Correction of machine lockup   
The lockup may occur while scanning non standard size originals (with 235 mm in 
width) on RSPF, displaying “Originals are being read”. 
 
 
 
 
20
 
Main unit 
control 
Implementation of selection whether to execute auto registration of user information in 
“User Control” -> “Default Settings” on main unit 
 
 
 
 
21
 
Main unit 
control 
Implementation of following features to erase cache information on authentication for 
cloud connection in User Control -> User List 
 
- Delete Your Information for External Connect 
- Delete All Information for External Connect 
 
 
 
 
22
 
Main unit 
control 
Addition of a mode which shows toner quantity in MIB until it turns “Empty” using 
values while toner quantity is “Low” 
SIM26-69 H (MIB TONER LOW INDIXATION) 
0: Retrieves information on toner quantity with value (Default) 
1. Retrieves “Low” status (-3) 
* “Toner Low” is not indicated with default condition. 
 
 
 
 
23
 
Main unit 
control 
Implementation of a Soft SW which turns on/off the confirmation message displayed 
when Blank Page Skip feature is enabled. 
SIM55-3 SW No.44   
Data 2 (Copy) 
Data 3 (Image Send) 
0: Display (Default) 
1: Do not display 
 
 
 
 
24
 
Main unit 
control 
Implementation of an error lamp setting in Device Settings with selections of “Not Use”, 
“Blink Only” and “Light & Blink” 
 
 
 
 
25
 
Main unit 
control 
Changing authentication setting for home directory during user registration from “Use 
Login Name And Password for User Authentication” to “Use Login Name for User 
Authentication” 
 
 
 
 
26
 
Main unit 
control 
Modification of behavior during Toner near end status as follows: 
- The alert on toner low is notified via E-RIC when an e-mail address is entered or 
“Toner Low” is selected on management web page. This won’t be affected whether 
SIM26-69 is set to A or C.   
SIM26-69 (Operating condition during toner near end) 
A: Whether to display a message to prompt preparation of toner 
C: Whether to display a message to notify toner near end 
 
 
 
 
27
 
Main unit 
control 
Correction of problem with touch panel which does not work in low temperature 
environment 
 
 
 
 
 
 
○=applied 
 
 
【Description】・・・(1) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
28
 
Main unit 
control 
Correction of failure to reboot MFP after firmware update 
 
 
 
 
29
 
Main unit 
control 
Collecting all log data in one folder in thumb drive when SIM56-99 (batch log data 
collection) is executed. 
 
 
 
 
30
 
Main unit 
control 
Correction of machine lockup which may occur when authentication using an IC card is 
executed while primarily requesting the authentication to an authentication server 
 
 
 
 
31
 
Main unit 
control 
Correction of machine lockup which occurs while searching an address in the Address 
Book 
 
 
 
 
32
 
Main unit 
control 
Correction of failure with keyboard 
The operating “CAPS” key on software keyboard turns on the Num Lock on external 
keyboard being connected, illuminating the LED. 
 
 
 
 
33
 
Main unit 
control 
Correction of recording unnecessary logs in Active Directory environment 
 
 
 
 
34
 
Main unit 
control 
Correction of MPF reboot after execution of User Control -> User Count -> Save User 
Count -> Print and Delete the Data 
 
 
 
 
35
 
Main unit 
control 
Correction of fuser motor keeps running with low speed after opening Right cover 
 
 
 
 
36 
Main unit 
control 
Review of temperature correction during job (increased by 5-degree)   
 
 
NA 
NA 
37
 
Main unit 
control 
Correction of H3-01 occasionally caused by printing a large number of envelopes 
 
 
 
 
38
 
Main unit 
control 
Modification of software control to prevent H3 trouble due to overshoot. 
 
 
 
 
39
 
Main unit 
control 
Fusing belt unit for MX-5050N/5070N/6050N/6070N series was changed from May 
2017 production.    For the purpose to avoid the low temperature offset, the fusing 
temperature control function has been added to Soft SW and the default value has 
been changed. 
For machines before May 2017 production, the modification has been made so that 
the set value does not automatically change even when updating the firmware to this 
version.   
If the set value is manually changed from 0 to 1, the high temperature offset may 
occur. 
In addition, if the setting of Soft SW is changed from 0 to 1 while the fusing belt unit 
before May 2017 production is installed, the high temperature offset may occur. 
*Changed fusing unit is supplied as the service parts.    This will be announced on 
Service Information later. 
 
SIM55-1 SW No.22 Data 8 
MX-5150FN/6150FN/5170FN/6170FN series 
0: Not control the temperature 
1: Control the temperature (Default) 
    
MX-3050N/3550N/4050N/3060N/3560N/4060N/3070N/3570N/4070N series 
0: Not control the temperature   
1: Not control the temperature (Default) 
 
*On MX-3050N/3060N/3070N series, both 0 and 1 are set to “Not control the 
temperature” because Fusing belt unit has not been changed. 
NA 
NA 
○ 
○ 
 
 
○=applied 
Page of 10
Display

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Service Manual ↓ Size: 365.34 KB | Pages: 10 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Copying Equipment. Information contained in Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.