DOWNLOAD Sharp MX-2614N / MX-3114N (serv.man7) Service Manual ↓ Size: 70.27 MB | Pages: 127 in PDF or view online for FREE

Model
MX-2614N MX-3114N (serv.man7)
Pages
127
Size
70.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual Complete - Dec 12
File
mx-2614n-mx-3114n-sm7.pdf
Date

Sharp MX-2614N / MX-3114N (serv.man7) Service Manual ▷ View online

MX-3114N  EXTERNAL VIEW AND INTERNAL STRUCTURE  4 – 23
14. Fuses and Thermostats
Signal name
Name
100v series
200v series
Section
F1
Fuse
20A 250V 
T10AH 250V 
AC Power PWB
F2
Fuse
-
T10AH 250V 
AC Power PWB
F001
Fuse
T12AH 250V
T6.3AH 250V
DC Power PWB
F003
Fuse
T3.15AH 250V
T3.15AH 250V
DC Power PWB
F101
Fuse
F10AH 250V (F101)
F5AH 250V (F101)
DC Power PWB
F401
Fuse
F3.15AH 250V (F401)
F2AH 250V (F401)
DC Power PWB
F201
Fuse
6.3A
6.3A
DC Power PWB
F202
Fuse
6.3A
6.3A
DC Power PWB
F203
Fuse
6.3A
6.3A
DC Power PWB
F204
Fuse
6.3A
6.3A
DC Power PWB
F205
Fuse
4.0A
4.0A
DC Power PWB
Signal name
Name
Type
Function/Operation
TS LM
Thermostat LM
Mechanical thermostat
Shuts down the heater lamp (HL_LM) circuit when the fusing section is overheated.
TS UM
Thermostat UM
Mechanical thermostat
Shuts down the heater lamp (HL_UM) circuit when the fusing section is overheated. 
(Center section)
TS US
Thermostat US
Mechanical thermostat
Shuts down the heater lamp (HL_US) circuit when the fusing section is overheated. 
(Edge section)
43
43?5-
&
&
&
&
&
&
&
&
&
&
&
43?53
MX-3114N  ADJUSTMENTS AND SETTINGS  5 – 1
MX-3114N
Service Manual
 
[5] ADJUSTMENTS AND SETTINGS
1. General
Each adjustment item in the adjustment item list is associated with
a specific Job number. Perform the adjustment procedures in the
sequence of Job numbers from the smallest to the greatest.
However, there is no need to perform all the adjustment items. Per-
form only the necessary adjustments according to the need.
Unnecessary adjustments can be omitted. Even in this case, how-
ever, the sequence from the smallest to the greatest Job number
must be observed.
If the above precaution should be neglected, the adjustment would
not complete normally or trouble may occur.
2. Adjustment item list
Job No.
Adjustment item list
Simulation
ADJ 1
Adjust the developing unit
1A
Adjust the developing doctor gap
1B
Adjust the developing roller main pole position
1C
Toner density control reference value setting
25-2
ADJ 2
Adjusting high voltage values
2A
Adjust the main charger grid voltage
8-2
2B
Adjust the developing bias voltage
8-1
2C
Transfer current and voltage adjustment
8-6
ADJ 3
Image density sensor 
adjustment
3A
Image density sensor adjustment
44-2
ADJ 4
Image lead edge position, image 
loss, void area, image off-center, 
image magnification ratio 
adjustment 
(Automatic adjustment)
4A
Print image main scanning direction automatic magnification ratio adjustment (Print engine)
50-28
4B
Print image off-center automatic adjustment (Print engine) (Each paper feed tray)
50-28
4C
Copy mode image lead edge position, image loss, void area, image off-center, sub scanning 
direction image magnification ratio automatic adjustment (Scanner) 
(Document table mode)
50-28
4D
Copy mode image lead edge position, image loss, void area, image off-center, sub scanning 
direction image magnification ratio automatic adjustment (Scanner) (RSPF mode)
50-28
ADJ 5
Print engine image distortion 
adjustment / OPC drum phase 
adjustment / Color registration 
adjustment (Print engine 
section)
5A
Print engine image distortion adjustment (Manual adjustment) / OPC drum phase adjustment 
(Automatic adjustment) / Color registration adjustment (Automatic adjustment)
50-22
5B
Print engine image skew (LSU skew) adjustment (Manual adjustment) 
(No need to adjust normally)
50-20 (64-1)
5C
Color registration offset adjustment (No need to adjust normally)
50-20
ADJ 6
Scan image distortion 
adjustment 
(Document table mode)
6A
Scanner (reading) unit parallelism adjustment
6B
Scan image (sub scanning direction) distortion adjustment
6C
Scan image (main scanning direction) distortion adjustment
ADJ 7
Scanner image skew adjustment (RSPF mode)
64-2
ADJ 8
Scan image focus adjustment
48-1
ADJ 9
Print lead edge image position adjustment (Printer mode)
50-5
ADJ 10/
SET1
Color balance and density 
adjustment
Note before execution of the 
image quality adjustment
Copy image quality check
Printer image quality check
10A
Scanner calibration (CCD 
calibration)
63-3 (63-5)
SET 
1
Color balance adjustment target 
setup
1A
Copy color balance adjustment target setup
63-7/8/11
1B
Printer color balance adjustment target setup
67-26/27/28
10B
Copy/Printer color balance and 
density adjustment (Automatic 
adjustment) 
(Basic adjustment)
46-74
10C
Copy image quality adjustment 
(Basic adjustment)
10C 
(1)
Copy color balance and density adjustment 
(Automatic adjustment)
46-24
10C 
(2)
Copy color balance and density adjustment 
(Manual adjustment)
46-21
10D
Copy / Image send / FAX image 
quality adjustment (Individual 
adjustment)
10D 
(1)
Color copy density adjustment (for each color copy 
mode) (separately for the low-density area and the 
high-density area) 
(No need to adjust normally)
46-1
10D 
(2)
Monochrome copy density adjustment (for each 
monochrome copy mode) (separately for the low-
density area and the high-density area) 
(No need to adjust normally)
46-2
10D 
(3)
Color copy color balance, gamma adjustment 
(for each color copy mode) 
(No need to adjust normally)
46-10
10D 
(4)
Monochrome copy density, gamma adjustment (for 
each monochrome copy mode) 
(No need to adjust normally)
46-16
MX-3114N  ADJUSTMENTS AND SETTINGS  5 – 2
ADJ 10/
SET1
Color balance and density 
adjustment
10D
Copy / Image send / FAX image 
quality adjustment (Individual 
adjustment)
10D 
(5)
Automatic monochrome (Copy/Scan/FAX) mode 
document density scanning operation (exposure 
operation) conditions setting 
(Normally no need to set)
46-19
10D 
(6)
Document low density image density reproduction 
adjustment in the automatic monochrome (Copy/
Scan/FAX) mode (No need to adjust normally) 
(Background density adjustment in the scanning 
section)
46-32
10D 
(7)
Copy/Scan low density image density adjustment 
(for each mode) (No need to adjust normally)
46-63
10D 
(8)
Color copy, text, line image reproduction 
adjustment (edge gamma, density adjustment) 
(Text, Map mode) (No need to adjust normally)
46-27
10D 
(9)
Monochrome (Copy/Scan/FAX) mode color 
document reproduction adjustment  (No need to 
adjust normally)
46-37
10D 
(10)
Color copy mode dark area gradation (black 
component quantity) adjustment  (No need to 
adjust normally)
46-38
10D 
(11)
Color (Copy/Scan) mode sharpness adjustment 
(No need to adjust normally)
46-60
10D 
(12)
Copy high density image density reproduction 
setting
(Normally unnecessary to the setting change)
46-23
10D 
(13)
Copy color balance adjustment (Single color copy 
mode) (No need to adjust normally)
46-25
10D 
(14)
RSPF mode (Copy/Scan/FAX) density adjustment 
(No need to adjust normally
46-9
10D 
(15)
Automatic color balance adjustment by the user 
(Copy color balance automatic adjustment 
ENABLE setting and adjustment)
26-53
10D 
(16)
Copy gamma, color balance adjustment for each 
dither (Automatic adjustment)
46-54
10E
Printer image quality adjustment 
(Basic adjustment)
10E 
(1)
Printer color balance adjustment 
(Automatic adjustment)
67-24
10E 
(2)
Printer color balance adjustment 
(Manual adjustment)
67-25
10F
Printer image quality adjustment 
(Individual adjustment)
10F 
(1)
Printer density adjustment (Low density section 
density adjustment) (No need to adjust normally)
67-36
10F 
(2)
Printer high density image density reproduction 
setting (Supporting the high density section tone 
gap) (No need to adjust normally)
67-34
10F 
(3)
Printer gamma adjustment for each dither 
(Automatic adjustment) (No need to adjust 
normally) (Except for GDI printers)
67-54
10F 
(4)
Automatic color balance adjustment by the 
user(Printer color balance automatic adjustment
ENABLE setting and adjustment)
(Normally unnecessary to the setting change)
26-53
ADJ 11
Paper size sensor adjustment
11A
Manual paper feed tray paper size (width) sensor adjustment
40-2
11B
RSPF paper feed tray document size (width) sensor adjustment
53-6
ADJ 12
Document size detection 
adjustment
12A
Document size sensor detection point adjustment
41-1
12B
Adjust the sensitivity of the original size sensor
41-2
ADJ 13
Touch panel coordinate setting
65-1
ADJ 14
Fusing paper guide position adjustment
ADJ 15
Print image position, image 
magnification ratio, void area, 
off-center adjustment (Print 
engine) (Manual adjustment)
15A
Print image magnification ratio adjustment (main scanning direction) (Print engine) 
(Manual adjustment)
50-10
15B
Print image print area adjustment (Print engine) (Manual adjustment)
50-10/50/1
15C
Print image off-center adjustment (Print engine) (Manual adjustment)
50-10
ADJ 16
Scan image magnification ratio 
adjustment (Manual adjustment)
16A
Scan image magnification ratio adjustment (main scanning direction) (Manual adjustment) 
(Document table mode)
48-1
16B
Scan image magnification ratio adjustment (sub scanning direction) (Manual adjustment) 
(Document table mode)
48-1/48-5
16C
Scan image magnification ratio adjustment (main scanning direction) (Manual adjustment) 
(RSPF mode)
48-1
16D
Scan image magnification ratio adjustment (sub scanning direction) (Manual adjustment) 
(RSPF mode)
48-1
ADJ 17
Scan image off-center 
adjustment (Manual adjustment)
17A
Scan image off-center adjustment (Manual adjustment) (Document table mode)
50-12
17B
Scan image off-center adjustment (Manual adjustment) (RSPF mode)
50-12/50-6
ADJ 18
Copy image position, image loss 
adjustment (Manual adjustment)
18A
Copy image position, image loss, void area adjustment (Manual adjustment) 
(Document table mode)
50-1
18B
Image scanning position adjustment (Manual adjustment) (RSPF mode)
53-8
18C
Copy image position, image loss, void area adjustment (Manual adjustment) (RSPF mode)
50-6
ADJ 19
Finisher and punch unit adjustments (alignment, punch hole position, staple position)
3-10
Job No.
Adjustment item list
Simulation
MX-3114N  ADJUSTMENTS AND SETTINGS  5 – 3
3. Details of adjustment
 
ADJ 1
Adjust the developing unit
 
1-A
Adjust the developing doctor gap
This adjustment must be performed in the following cases:
* The developing unit has been disassembled.
* When the print image density is low.
* When there is a blur on the print image.
* When there is unevenness in the print image density.
* The toner is excessively dispersed.
Be careful not to attach a fingerprint, oil, grease, or a foreign mate-
rial on the DV roller during the procedure. Also be careful not to
scratch the DV roller surface.
If a fingerprint, oil, grease, or a foreign material is erroneously
attached to the DV roller during the procedure, remove all devel-
oper from the developing unit and clean the roller with alcohol.
Do not exert force when holding the DV Unit.
1)
Remove the developing unit from the main unit, and remove
the developing doctor cover.
2)
Loosen the developing doctor fixing screw.
3)
Insert a thickness gauge of 0.65mm in between 40mm - 70mm
from the edge of the developing doctor.
Note for use of a thickness gauge
 Do not insert the gauge diagonally.
 The gauge must pass freely.
 The advisable point of measurement is the MIN point of the 
DV roller oscillation.
4)
Push the developing doctor in the arrow direction, and tighten
the fixing screw of the developing doctor. (Perform the similar
procedure for the front frame and the rear frame.)
5)
Check that the doctor gaps at two positions in 40mm - 70mm
from the both sides of the developing doctor are in the range of
0.65 
 0.05mm.
 
1-B
Adjust the developing roller main pole 
position
This adjustment must be performed in the following cases:
* The developing unit has been disassembled.
* When the print image density is low.
* When there is a blur on the print image.
* When there is unevenness in the print image density.
* The toner is excessively dispersed.
Be careful not to leave a fingerprint, oil, grease, or a foreign mate-
rial on the DV roller during the procedure. Also be careful not to
scratch the DV roller surface.
If a fingerprint, oil, grease, or a foreign material is erroneously
attached to the DV roller during the procedure, remove all devel-
oper from the developing unit and clean the roller with alcohol.
Do not exert force when holding the DV Unit.
1)
Remove the developing doctor cover, and place the develop-
ing unit on a flat surface.
2)
Attach a piece of string to a sewing needle or pin.
3)
Hold the thread and bring the needle near the developing
roller. (Do not use a paper clip because too heavy. It will not
provide a correct position.)
40mm
70mm
40mm
70mm
40mm
70mm
40mm
70mm
Page of 127
Display

Click on the first or last page to see other MX-2614N / MX-3114N (serv.man7) service manuals if exist.